AR Plumber study plan
AR Plumber · Give each week a clear focus.
8 weeks · About 7 hours per week
Sanitary Drainage Systems
Compute fixture-unit loads for a building drain, building sewer, and every branch interval in a two-story dwelling
Calculate developed length of a drainage run and verify that each horizontal section meets its required slope
Determine pipe size and fitting type at each change of direction, and identify prohibited drainage fittings and configurations
Lay out a complete sanitary drainage system in isometric view for a three-fixture-group house, labeling every size and slope
Your checkpoint
A labeled drainage isometric for a two-story dwelling with every pipe size, slope, and fitting annotated, plus a fixture-unit calculation worksheet showing each branch load
Sanitary Drainage Systems & Water Supply and Distribution Systems
Diagnose and correct five common drainage layout errors, including improper stack-to-drain connections and inadequate cleanout placement
Convert water supply fixture-unit demand to probable flow in gallons per minute for a single-family service
Size a water service, main, and branch lines from a given fixture-unit load and developed length
Select pipe material for supply and distribution and state the approved joining method for each
Your checkpoint
A completed sizing worksheet for a 2.5-bath dwelling giving service size, main size, and branch sizes with a written justification for each number
Water Supply and Distribution Systems & Vents and Venting Systems
Size vents from drainage fixture units and developed length for stacks, branches, and individual fixtures
Distinguish common, individual, wet, circuit, and stack vents, and select the correct type for each fixture in a given layout
Verify vent terminal locations against required clearances from openings, air intakes, and property lines
Trace a vent system from each trap to open air and identify every point where a vent is improperly combined
Your checkpoint
A venting diagram for a two-bath layout showing vent type, size, and connection point for each fixture, with a one-line justification per vent
Vents and Venting Systems & Plumbing Mathematics, Sizing, and Isometric Analysis
Solve 45-degree and 22.5-degree offset problems, computing travel, run, and fitting take-out for each
Convert between fixture units, gallons per minute, pipe diameter, and velocity using standard formulas
Read a blank isometric and derive every pipe size from the fixture-unit table without referencing a completed drawing
Work time-limited calculation sets so that sizing decisions take under three minutes per problem
Your checkpoint
Two blank-sheet isometrics completed in 30 minutes each with correct sizes, plus a 25-question timed math set scored at 80 percent or higher with worked solutions for every miss
Arkansas Plumbing Law, Rules, and Licensing Requirements & Plumbing Fixtures, Faucets, and Fixture Fittings
Outline the Arkansas plumbing licensing sequence: apprentice registration, journeyman eligibility, master eligibility, and renewal obligations
Identify who may pull a plumbing permit, who may supervise work, and what triggers disciplinary action under state rules
Set minimum fixture counts and clearances for a given occupancy type, including water closet, lavatory, and bathtub spacing
Verify installation requirements for fixture fittings, water closet connections, and floor-mounted versus wall-mounted support
Your checkpoint
A two-page compliance packet: one page of Arkansas licensing and supervision steps in sequence, one page of a bathroom fixture layout meeting all spacing and clearance minimums
Traps, Interceptors, and Backflow Prevention & General Regulations, Permits, and Code Administration
Select the correct trap for each fixture and verify trap seal depth, distance to vent, and protection against siphonage
Classify six cross-connection scenarios and specify air gap, reduced pressure principle assembly, pressure vacuum breaker, or double check valve for each
Size a grease interceptor and a sand/oil interceptor for given fixture discharge rates
Sequence the permit and inspection process from application through final approval, naming who may perform each step
Your checkpoint
A backflow protection decision matrix covering six scenarios with justification per row, plus a permit-to-final inspection timeline for a residential remodel
Water Heaters and Temperature Control & Special Systems: Storm Drainage, Fuel Gas Piping, and Specialty Plumbing
Size a water heater for a given dwelling and compute recovery rate and temperature rise
Specify the relief valve rating, discharge pipe material, and termination point for a water heater installation
Size vertical storm conductors and horizontal storm drains from roof area and rainfall rate
Compute fuel gas pipe size from appliance Btu input, run length, and gas specific gravity using the longest-length method
Your checkpoint
A water heater installation spec sheet covering capacity, relief valve, and discharge routing, plus a gas pipe sizing calculation for a three-appliance run
Arkansas Plumbing Law, Rules, and Licensing Requirements & General Regulations, Permits, and Code Administration & Plumbing Mathematics, Sizing, and Isometric Analysis & Water Supply and Distribution Systems & Plumbing Fixtures, Faucets, and Fixture Fittings & Sanitary Drainage Systems & Vents and Venting Systems & Traps, Interceptors, and Backflow Prevention & Water Heaters and Temperature Control & Special Systems: Storm Drainage, Fuel Gas Piping, and Specialty Plumbing
Complete two full-length timed practice exams and score 80 percent or higher on each
Re-work every missed item from weeks 1 through 7 into a single error log keyed by domain
Recite from memory the Arkansas licensing sequence and the permit and inspection steps
Drill weak domains until no domain scores below 70 percent
Your checkpoint
A final error log with every missed item corrected and annotated, plus score reports from two consecutive full-length practice exams
Milestones
Week 2: Score 75 percent or higher on a 20-question sanitary drainage and water supply sizing quiz with no notes
Week 4: Produce a complete drainage and venting isometric from a blank sheet in 30 minutes with all pipe sizes correct
Week 6: Correctly classify 90 percent or more of backflow scenarios and licensing facts on a mixed 30-question set
Week 8: Two consecutive full-length practice exams at 80 percent or higher overall, with no single domain below 70 percent