SPI study materials
SPI study resources

SPI study plan

SPI · Give each week a clear focus.

8 weeks · About 7 hours per week

Week 1

Physical Principles and Instrumentation

  • Define and distinguish the wave parameters (frequency, period, wavelength, amplitude, power, intensity, speed) and state how each changes when the sound travels from one medium to another

  • Compute propagation speed, wavelength, and period from given values without a calculator shortcut sheet

  • Apply the decibel system to express intensity and amplitude ratios and to solve attenuation-in-dB problems using the 0.5 dB/cm/MHz rule

  • Explain acoustic impedance and predict the relative size of a reflection at soft-tissue, bone, and air interfaces

  • Describe reflection, refraction, scattering, and absorption, and rank tissues by attenuation

Your checkpoint

A one-page handwritten formula sheet (speed, wavelength, dB, attenuation, impedance, half-value layer) self-tested by reciting it from memory with no errors

Week 2

Physical Principles and Instrumentation

  • Compare continuous wave and pulsed wave transducers by duty factor, bandwidth, Q factor, and the effect on axial resolution

  • Explain piezoelectric effect, element material properties, and the function of matching layer, backing material, and acoustic lens

  • Differentiate axial, lateral, elevational, and temporal resolution and state the instrument determinant of each

  • Describe beam formation, focal zone, near/far field (Fresnel/Fraunhofer), and how aperture, frequency, and focusing alter beam width

  • Sequence the signal path through the beam former, receiver, amplifier, demodulator, and scan converter, and classify each control as pre- or post-processing

Your checkpoint

A labeled hand-drawn diagram of the pulse-echo signal path with each resolution type and its determinant annotated, checked against a written accuracy list

Week 3

Physical Principles and Instrumentation & Doppler and Hemodynamics

  • Explain image formation for each display mode (A, B, M, 2D) and describe how frame rate, line density, depth, and field of view trade off against temporal resolution

  • Calculate frame rate, PRF, PRP, and duty factor from given depth and line-count values

  • State the Doppler equation and identify which variables the technologist can and cannot control

  • Contrast continuous wave and pulsed wave Doppler by range resolution, maximum velocity detectable, and typical clinical use

  • Interpret the spectral waveform display: baseline, scale, direction, window, and the meaning of spectral broadening

Your checkpoint

A 20-question self-written quiz on frame rate/PRF calculations and Doppler equation variables, scored at 85% or better on a closed-book retake

Week 4

Doppler and Hemodynamics

  • Predict and explain aliasing from PRF, Nyquist limit, frequency, depth, and angle, and list at least five corrective actions in order of preference

  • Describe color Doppler and color power Doppler by principle, advantages, limitations, and frame-rate cost

  • Apply the Doppler angle correction rule and evaluate the error introduced at 60 degrees versus steeper angles

  • Relate pressure gradient, Bernoulli equation, continuity equation, and resistance to spectral waveform shape and pulsatility

  • Distinguish high-resistance from low-resistance waveforms and identify normal versus abnormal spectral findings at common vascular and cardiac sites

Your checkpoint

A written table of 10 clinical scenarios listing the suspected Doppler problem (aliasing, angle error, wall filter, gain too high, etc.), the corrective control, and the expected effect on the waveform

Week 5

Quality Assurance, Safety and Artifacts

  • Explain the mechanisms of bioeffects (thermal and mechanical/cavitation) and the conditions that favor each

  • Interpret thermal index and mechanical index values and apply the ALARA principle to adjust output, dwell time, and mode

  • Recall the key regulatory and advisory output limits (TI, MI, intensity, and the 8-hour exposure concept) and identify which are not under operator control

  • List and explain the components of a routine quality assurance program including phantom tests, uniformity, and dead-zone checks

  • Identify the causes and correct display of the major artifacts: reverberation, comet tail, shadowing, enhancement, mirror image, speed error, and slice-thickness

Your checkpoint

A two-column artifact-and-safety study card set (minimum 15 entries) matching each artifact or bioeffect term to its cause and its fix, verified by a peer or answer key

Week 6

Quality Assurance, Safety and Artifacts & Doppler and Hemodynamics

  • Design a monthly QA schedule that specifies which parameter is measured, with what device, and against what acceptance threshold

  • Explain receiver/display test metrics: sensitivity, uniformity, axial and lateral resolution, max depth, and vertical/horizontal distance accuracy

  • Diagnose system faults from image appearance (dropout, banding, dead elements, electrical interference) and state the escalation step

  • Re-derive Doppler correction actions and safety trade-offs for high-output modes such as spectral Doppler and color Doppler

  • Combine safety, artifact recognition, and Doppler settings into a single troubleshooting decision sequence

Your checkpoint

A completed mock QA log covering 10 simulated image defects, each with a probable cause, a verification test, and a pass/fail threshold

Week 7

Physical Principles and Instrumentation & Doppler and Hemodynamics & Quality Assurance, Safety and Artifacts

  • Rank your weakest five subtopics from prior weeks' scores and rebuild each from first principles

  • Solve mixed calculation sets spanning attenuation, frame rate, Nyquist, PRF, and resolution under a 1-minute-per-question limit

  • Write and answer 30 original questions that combine two domains (for example, an artifact question that depends on transducer physics)

  • Re-teach the highest-yield concepts aloud from memory and correct any self-identified gaps

  • Rehearse instrument control adjustments by predicting the effect of each knob on image and Doppler display

Your checkpoint

A written error log of at least 25 missed items with the corrected reasoning and the underlying principle, reviewed to zero remaining open entries

Week 8

Physical Principles and Instrumentation & Doppler and Hemodynamics & Quality Assurance, Safety and Artifacts

  • Complete three timed full-length practice exams under test-day conditions and score each immediately

  • Recompute every missed calculation and classify each remaining error as knowledge, calculation, or misread

  • Recite the full formula sheet plus the safety limit values from memory with no errors

  • Review only high-yield summaries and the week-7 error log for the final two days; avoid new material

  • Confirm test-day logistics, timing strategy, and a plan for flagging and returning to uncertain items

Your checkpoint

Three scored practice exams with a final error analysis showing at least 85% on the last attempt and no unresolved calculation errors

Milestones

Week 2: Recite the complete formula sheet from memory and score 90% or better on a self-made 25-question Domain 1 physics quiz without notes

Week 4: Score 80% or better on a closed-book Domain 2 Doppler and hemodynamics quiz, including at least five aliasing and angle-correction scenarios

Week 6: Score 80% or better on a combined Domain 3 safety, artifact, and QA quiz and produce a complete, correctly thresholded QA log

Week 7: Error log has no open entries and mixed-domain timed calculation sets average 80% or better

Week 8: Third timed full-length practice exam scores 85% or better with balanced performance across all three domains