ARE 5.0: PPD study plan
ARE 5.0: PPD · Give each week a clear focus.
8 weeks · About 7 hours per week
Building Systems, Materials & Assemblies
Build a comparison matrix of four structural systems (steel, cast-in-place concrete, wood, masonry) recording typical bay spans, lateral-force-resisting strategy, and framing depth.
Draw a schematic building section that reserves horizontal and vertical zones for structure, supply and return air, plumbing, and power, and dimension each zone.
Assemble a material properties sheet for eight common finish and assembly types listing fire rating, acoustic performance, and moisture sensitivity.
Trace the path of a duct, a drain stack, and a conduit run from origin to termination through your section and mark every point where they fight for the same space.
Your checkpoint
A single-page systems matrix plus an annotated schematic section covering four structural systems and three distribution strategies, with span, depth, and coordination notes for each.
Building Systems, Materials & Assemblies & Environmental Conditions & Context
Calculate the U-value of three different wall assemblies from layer R-values and compare each against a target value you set in advance.
Position the air barrier, vapor retarder, and insulation in three envelope assemblies and write a dew-point justification for each placement decision.
Sketch summer solstice, equinox, and winter solstice sun paths for a chosen latitude and derive shadow angles for a horizontal and a vertical shading device.
Classify a site by climate zone and select three passive strategies, stating the specific building feature each strategy requires.
Your checkpoint
Three annotated wall sections with complete U-value arithmetic and a one-paragraph moisture-control rationale per section, plus one shading study sketch.
Environmental Conditions & Context
Analyze a hypothetical site for solar exposure, prevailing wind, drainage, noise, and access, and rank the findings by design impact.
Lay out a building footprint on that site that responds to orientation, setback, and stormwater run-off constraints, and justify each move in writing.
Size a daylighting strategy for a 30-foot-deep open office using window head height, sill height, and room depth relationships.
Compare two massing options for the same program and document how each changes heat gain, daylight, and usable area.
Your checkpoint
A two-page site and climate analysis package: annotated site plan, massing comparison, and a daylighting sketch with dimensions and reasoning.
Project Integration of Program & Systems & Environmental Conditions & Context
Build a program adjacency matrix for a mixed-use building and derive a block-and-stack diagram from it.
Overlay the structural grid from week one onto the block-and-stack diagram and resolve at least three conflicts between bay size and room module.
Produce a reflected ceiling plan coordinating light fixtures, air diffusers, sprinkler heads, and structural framing without clashes.
Write a one-page sequence describing how program, structure, and building systems decisions constrain one another across design phases.
Your checkpoint
A coordinated block-and-stack diagram plus a drawn ceiling plan with a written conflict log identifying every clash found and how it was resolved.
Project Integration of Program & Systems & Codes & Regulations
Determine occupancy classification and required fire separation for each tenant in a mixed-occupancy building and record the triggers that change the answer.
Trace exit access travel distance and path of egress travel from the farthest point of a floor plate to exit discharge and flag every point of noncompliance.
Select fire-rated wall and floor assemblies from a code table and enter them into a wall type schedule with hourly ratings.
Integrate the mechanical shaft and egress stair into the structural grid without reducing required clear width.
Your checkpoint
A one-page code and egress summary for the week-4 building with occupancy classifications, travel distances, rated assemblies, and a marked-up egress plan.
Codes & Regulations
Calculate occupant load and required egress capacity for a floor plate using occupant load factors, then verify the number and width of exits.
Determine allowable building height and floor area from construction type and occupancy, then apply a frontage increase and show the arithmetic.
Apply accessibility requirements to a restroom layout and a parking layout, dimensioning clear floor space, turning radius, and accessible stall counts.
Map zoning constraints including setbacks, floor area ratio, and height limit onto a massing study and identify the binding constraint.
Your checkpoint
A one-page code calculation sheet showing occupant load, egress width, allowable area with frontage math, and the resulting massing envelope.
Project Costs & Budgeting & Codes & Regulations
Prepare a schematic-level cost estimate for three building types using unit costs per square foot and per unit, and state the assumptions behind each number.
Itemize every budget line beyond hard construction cost, including contingency, escalation, soft costs, site work, and owner allowances.
Quantify how a change in structural system or envelope performance shifts the estimate by a defined percentage and identify which line items move.
Compare the twenty-year life-cycle cost of two HVAC options using first cost, energy use, and replacement intervals.
Your checkpoint
A cost model table for one building with hard costs, soft costs, contingency, escalation, and a side-by-side life-cycle comparison of two system options.
Environmental Conditions & Context & Codes & Regulations & Building Systems, Materials & Assemblies & Project Integration of Program & Systems & Project Costs & Budgeting
Complete a full-length timed practice exam under test conditions and score each of the five domains separately.
Re-study the two lowest-scoring domains and rewrite each missed concept as a corrected one-sentence rule you can apply cold.
Rehearse two integrated scenarios that combine program, structural, envelope, code, and cost decisions in a single narrative.
Condense all eight weeks of notes into a one-page decision checklist organized by design phase.
Your checkpoint
A scored full-length practice exam with a written error log that names the cause of every miss and the corrected rule for each.
Milestones
Week 2: Score at least 80 percent on a 20-question self-quiz on structural, envelope, and MEP fundamentals that you write from your own notes, and log the reason for every miss.
Week 4: Review the coordinated ceiling and structural plan against a 15-item integration checklist and satisfy at least 12 items before moving on.
Week 6: Score at least 75 percent on a 30-question mixed quiz covering codes, egress, accessibility, and zoning, and resolve every missed item within the same week.
Week 8: Complete the full-length timed practice exam at or above your target scaled score with no individual domain below 60 percent.