ARRT Nuclear Medicine study materials
ARRT Nuclear Medicine study resources

ARRT Nuclear Medicine cheat sheet

ARRT Nuclear Medicine · Keep the key ideas within reach.

Quick reference

Diagnostic Procedures / Clinical Applications

  • Tc-99m MDP bone scintigraphy uses flow, blood-pool, and delayed phases; focal increased uptake reflects osteoblastic activity, while photopenic foci can indicate aggressive lysis, infarction, or prosthesis.

  • Myocardial perfusion uses stress and rest Tc-99m sestamibi or tetrofosmin; a defect that improves at rest is reversible ischemia, whereas a fixed defect suggests scar or attenuation artifact.

  • V/Q lung scan uses Tc-99m MAA perfusion and aerosol or technegas ventilation; a perfusion defect with normal ventilation (mismatch) raises PE probability, especially with high clinical pretest probability.

  • Hepatobiliary scan uses Tc-99m mebrofenin or disofenin; gallbladder nonvisualization at 4 hours with intestinal activity suggests acute cholecystitis, and morphine augmentation can shorten the study.

  • Renal scintigraphy uses Tc-99m DTPA for GFR, Tc-99m MAG3 for tubular secretion and ERPF, and Tc-99m DMSA for cortical imaging; captopril renography assesses renovascular hypertension.

  • Thyroid imaging uses Tc-99m pertechnetate or I-123; a cold nodule requires correlation, and I-131 whole-body scanning follows thyroidectomy for differentiated thyroid cancer.

  • GI bleeding imaging with Tc-99m RBC can detect bleeding at approximately 0.1 mL/min; Meckel diverticulum imaging uses Tc-99m pertechnetate uptake by ectopic gastric mucosa.

  • Sentinel node lymphoscintigraphy uses Tc-99m sulfur colloid or tilmanocept injected near the tumor; the first draining node is identified with a gamma probe for biopsy.

  • Brain death imaging uses Tc-99m DTPA or HMPAO to demonstrate absent cerebral perfusion; the study must follow institutional criteria and may be confounded by scalp or venous activity.

Quick reference

Radiopharmacy and Radiopharmaceuticals

  • Mo-99/Tc-99m generator: Mo-99 (66 h) decays to Tc-99m (6.01 h); eluate must be assayed for Mo-99 breakthrough, with a limit of 0.15 kBq per MBq (0.15 µCi/mCi) Tc-99m.

  • Aluminum breakthrough limit is 10 µg/mL of eluate; excess Al3+ can aggregate particulate radiopharmaceuticals and alter biodistribution.

  • Purity types include radionuclidic purity (unwanted radionuclides), radiochemical purity (desired chemical form), chemical purity (nonradioactive impurities), plus sterility and apyrogenicity.

  • Common Tc-99m agents: MDP for bone, MAA for lung perfusion, MAG3 for renal tubular function, DTPA for GFR, sulfur colloid for liver/spleen/marrow, sestamibi for myocardial and parathyroid imaging, and pertechnetate for thyroid, Meckel, and gastric imaging.

  • PET isotopes: F-18 110 min, Ga-68 68 min, C-11 20 min, N-13 10 min, O-15 2 min, and Rb-82 76 sec; short half-lives dictate on-site production and rapid imaging.

  • Half-lives used for decay correction: I-131 8.02 days, I-123 13.2 h, Tc-99m 6.01 h, In-111 2.8 days, and Tl-201 73 h.

  • Kit preparation follows the package insert, verifies expiration and labeling efficiency, inspects for particles or discoloration, and uses aseptic technique with appropriate shielding.

  • Particle size: MAA 10-90 µm lodges in pulmonary capillaries; sulfur colloid 0.1-1 µm is phagocytosed by reticuloendothelial cells; filtered colloid is used for sentinel node mapping.

  • Dose calibration measures activity in a dose calibrator before administration and records time, activity, and volume, with decay correction to the calibration time on the label.

Quick reference

Instrumentation and Image Production (including PET and CT)

  • NaI(Tl) detector: a gamma ray produces light, photomultiplier tubes convert it to an electrical pulse, and a pulse-height analyzer selects the photopeak; energy resolution at Tc-99m 140 keV is about 10%.

  • Tc-99m photopeak window is commonly 140 keV ±10% (126-154 keV); I-131 is 364 keV and F-18 is 511 keV; incorrect windows increase scatter or lose true counts.

  • Collimator choice: parallel-hole preserves size, pinhole magnifies small organs, converging magnifies, and diverging minifies; resolution improves with longer holes and smaller hole diameter but sensitivity falls.

  • Daily gamma camera QC includes a uniformity flood; extrinsic uniformity includes the collimator; center of rotation and resolution/sensitivity checks follow defined schedules.

  • SPECT uses a 360-degree orbit with 60-120 projections; filtered backprojection or iterative reconstruction is used, with attenuation, scatter, and resolution recovery corrections improving quantitation.

  • PET detects 511-keV annihilation photons in coincidence; time-of-flight improves localization, and CT attenuation correction plus scatter correction are required for quantitative SUV.

  • CT numbers: water is 0 HU, air is about -1000 HU, and bone is high positive; window width and level control display, while pitch and mAs affect dose and image noise.

  • Image matrix: pixel size equals field of view divided by matrix width; a larger matrix yields smaller pixels but fewer counts per pixel, increasing noise unless counts are adequate.

  • High count rate causes dead time and pulse pileup; paralyzable systems show decreasing observed count rate at very high activity, so activity must be reduced or split.

Quick reference

Radiation Safety and Protection

  • ALARA: reduce time, increase distance, and use shielding; exposure rate obeys the inverse square law I1/I2 = (d2/d1)^2 for a point source.

  • NCRP occupational limits: 50 mSv/year effective dose, 150 mSv/year lens, and 500 mSv/year skin and extremities; the public limit is 1 mSv/year.

  • A declared pregnant worker has an embryo-fetus limit of 0.5 mSv/month and 5 mSv over gestation; duties are reviewed to maintain ALARA.

  • Half-value layer: lead HVL for Tc-99m is about 0.3 mm; a 0.5-mm lead apron attenuates a large fraction but not all gamma rays, and 511-keV PET photons require more shielding.

  • Waste decay: hold short-lived radionuclides for about 10 half-lives; Tc-99m requires about 60 hours and I-131 about 80 days; survey and document before disposal.

  • Contamination monitoring: a thin-window GM detector detects beta, a NaI scintillation detector detects gamma, and wipe tests identify removable contamination counted in a well counter.

  • Spill response: contain, mark, shield, survey personnel and area, remove contamination without spreading it, and report according to institutional and regulatory requirements.

  • Dose quantities: absorbed dose is in Gy, equivalent dose is in Sv with radiation weighting, and effective dose is in Sv with tissue weighting; these allow risk and limit comparisons.

  • Package receipt: survey the transport package, check removable contamination, verify the label and dosimeter, and document findings before radiopharmaceutical use.

Quick reference

Patient Care and Quality Control

  • Patient identification uses at least two identifiers and matches the dose label, order, and patient before administration; documentation includes radiopharmaceutical, activity, route, and time.

  • Pregnancy and lactation screening is performed before radiopharmaceutical administration; the authorized user provides fetal dose estimates and breastfeeding interruption guidance.

  • Dose calibrator QC includes daily constancy, quarterly linearity, quarterly accuracy, and geometry checks; results are recorded and the calibrator is removed from service if outside tolerance.

  • Gamma camera QC includes daily uniformity flood and periodic resolution, sensitivity, and center-of-rotation checks; collimator and detector artifacts are corrected before imaging.

  • Radiopharmaceutical QC includes visual inspection for particles or discoloration, pH where required, radiochemical purity by chromatography, and sterility or pyrogen testing per kit instructions.

  • Adverse reactions include anaphylaxis, vasovagal response, and extravasation; the study is stopped, basic life support is provided, the authorized user is notified, and the event is documented.

  • Pediatric dosing adjusts activity by weight or body surface area per institutional protocol; the smallest volume consistent with accurate counting is used and repeat imaging is minimized.

  • Patient instructions include hydration and frequent voiding to reduce bladder dose, plus breast-feeding and contact precautions specific to the radiopharmaceutical.

Quick reference

Diagnostic Procedures / Clinical Applications

  • Tc-99m MDP bone scintigraphy uses flow, blood-pool, and delayed phases; focal increased uptake reflects osteoblastic activity, while photopenic foci can indicate aggressive lysis, infarction, or prosthesis.

  • Myocardial perfusion uses stress and rest Tc-99m sestamibi or tetrofosmin; a defect that improves at rest is reversible ischemia, whereas a fixed defect suggests scar or attenuation artifact.

  • V/Q lung scan uses Tc-99m MAA perfusion and aerosol or technegas ventilation; a perfusion defect with normal ventilation (mismatch) raises PE probability, especially with high clinical pretest probability.

  • Hepatobiliary scan uses Tc-99m mebrofenin or disofenin; gallbladder nonvisualization at 4 hours with intestinal activity suggests acute cholecystitis, and morphine augmentation can shorten the study.

  • Renal scintigraphy uses Tc-99m DTPA for GFR, Tc-99m MAG3 for tubular secretion and ERPF, and Tc-99m DMSA for cortical imaging; captopril renography assesses renovascular hypertension.

  • Thyroid imaging uses Tc-99m pertechnetate or I-123; a cold nodule requires correlation, and I-131 whole-body scanning follows thyroidectomy for differentiated thyroid cancer.

  • GI bleeding imaging with Tc-99m RBC can detect bleeding at approximately 0.1 mL/min; Meckel diverticulum imaging uses Tc-99m pertechnetate uptake by ectopic gastric mucosa.

  • Sentinel node lymphoscintigraphy uses Tc-99m sulfur colloid or tilmanocept injected near the tumor; the first draining node is identified with a gamma probe for biopsy.

  • Brain death imaging uses Tc-99m DTPA or HMPAO to demonstrate absent cerebral perfusion; the study must follow institutional criteria and may be confounded by scalp or venous activity.

Quick reference

Radiopharmacy and Radiopharmaceuticals

  • Mo-99/Tc-99m generator: Mo-99 (66 h) decays to Tc-99m (6.01 h); eluate must be assayed for Mo-99 breakthrough, with a limit of 0.15 kBq per MBq (0.15 µCi/mCi) Tc-99m.

  • Aluminum breakthrough limit is 10 µg/mL of eluate; excess Al3+ can aggregate particulate radiopharmaceuticals and alter biodistribution.

  • Purity types include radionuclidic purity (unwanted radionuclides), radiochemical purity (desired chemical form), chemical purity (nonradioactive impurities), plus sterility and apyrogenicity.

  • Common Tc-99m agents: MDP for bone, MAA for lung perfusion, MAG3 for renal tubular function, DTPA for GFR, sulfur colloid for liver/spleen/marrow, sestamibi for myocardial and parathyroid imaging, and pertechnetate for thyroid, Meckel, and gastric imaging.

  • PET isotopes: F-18 110 min, Ga-68 68 min, C-11 20 min, N-13 10 min, O-15 2 min, and Rb-82 76 sec; short half-lives dictate on-site production and rapid imaging.

  • Half-lives used for decay correction: I-131 8.02 days, I-123 13.2 h, Tc-99m 6.01 h, In-111 2.8 days, and Tl-201 73 h.

  • Kit preparation follows the package insert, verifies expiration and labeling efficiency, inspects for particles or discoloration, and uses aseptic technique with appropriate shielding.

  • Particle size: MAA 10-90 µm lodges in pulmonary capillaries; sulfur colloid 0.1-1 µm is phagocytosed by reticuloendothelial cells; filtered colloid is used for sentinel node mapping.

  • Dose calibration measures activity in a dose calibrator before administration and records time, activity, and volume, with decay correction to the calibration time on the label.

Quick reference

Instrumentation and Image Production (including PET and CT)

  • NaI(Tl) detector: a gamma ray produces light, photomultiplier tubes convert it to an electrical pulse, and a pulse-height analyzer selects the photopeak; energy resolution at Tc-99m 140 keV is about 10%.

  • Tc-99m photopeak window is commonly 140 keV ±10% (126-154 keV); I-131 is 364 keV and F-18 is 511 keV; incorrect windows increase scatter or lose true counts.

  • Collimator choice: parallel-hole preserves size, pinhole magnifies small organs, converging magnifies, and diverging minifies; resolution improves with longer holes and smaller hole diameter but sensitivity falls.

  • Daily gamma camera QC includes a uniformity flood; extrinsic uniformity includes the collimator; center of rotation and resolution/sensitivity checks follow defined schedules.

  • SPECT uses a 360-degree orbit with 60-120 projections; filtered backprojection or iterative reconstruction is used, with attenuation, scatter, and resolution recovery corrections improving quantitation.

  • PET detects 511-keV annihilation photons in coincidence; time-of-flight improves localization, and CT attenuation correction plus scatter correction are required for quantitative SUV.

  • CT numbers: water is 0 HU, air is about -1000 HU, and bone is high positive; window width and level control display, while pitch and mAs affect dose and image noise.

  • Image matrix: pixel size equals field of view divided by matrix width; a larger matrix yields smaller pixels but fewer counts per pixel, increasing noise unless counts are adequate.

  • High count rate causes dead time and pulse pileup; paralyzable systems show decreasing observed count rate at very high activity, so activity must be reduced or split.

Quick reference

Radiation Safety and Protection

  • ALARA: reduce time, increase distance, and use shielding; exposure rate obeys the inverse square law I1/I2 = (d2/d1)^2 for a point source.

  • NCRP occupational limits: 50 mSv/year effective dose, 150 mSv/year lens, and 500 mSv/year skin and extremities; the public limit is 1 mSv/year.

  • A declared pregnant worker has an embryo-fetus limit of 0.5 mSv/month and 5 mSv over gestation; duties are reviewed to maintain ALARA.

  • Half-value layer: lead HVL for Tc-99m is about 0.3 mm; a 0.5-mm lead apron attenuates a large fraction but not all gamma rays, and 511-keV PET photons require more shielding.

  • Waste decay: hold short-lived radionuclides for about 10 half-lives; Tc-99m requires about 60 hours and I-131 about 80 days; survey and document before disposal.

  • Contamination monitoring: a thin-window GM detector detects beta, a NaI scintillation detector detects gamma, and wipe tests identify removable contamination counted in a well counter.

  • Spill response: contain, mark, shield, survey personnel and area, remove contamination without spreading it, and report according to institutional and regulatory requirements.

  • Dose quantities: absorbed dose is in Gy, equivalent dose is in Sv with radiation weighting, and effective dose is in Sv with tissue weighting; these allow risk and limit comparisons.

  • Package receipt: survey the transport package, check removable contamination, verify the label and dosimeter, and document findings before radiopharmaceutical use.

Quick reference

Patient Care and Quality Control

  • Patient identification uses at least two identifiers and matches the dose label, order, and patient before administration; documentation includes radiopharmaceutical, activity, route, and time.

  • Pregnancy and lactation screening is performed before radiopharmaceutical administration; the authorized user provides fetal dose estimates and breastfeeding interruption guidance.

  • Dose calibrator QC includes daily constancy, quarterly linearity, quarterly accuracy, and geometry checks; results are recorded and the calibrator is removed from service if outside tolerance.

  • Gamma camera QC includes daily uniformity flood and periodic resolution, sensitivity, and center-of-rotation checks; collimator and detector artifacts are corrected before imaging.

  • Radiopharmaceutical QC includes visual inspection for particles or discoloration, pH where required, radiochemical purity by chromatography, and sterility or pyrogen testing per kit instructions.

  • Adverse reactions include anaphylaxis, vasovagal response, and extravasation; the study is stopped, basic life support is provided, the authorized user is notified, and the event is documented.

  • Pediatric dosing adjusts activity by weight or body surface area per institutional protocol; the smallest volume consistent with accurate counting is used and repeat imaging is minimized.

  • Patient instructions include hydration and frequent voiding to reduce bladder dose, plus breast-feeding and contact precautions specific to the radiopharmaceutical.