ARRT Nuclear Medicine flashcards
ARRT Nuclear Medicine · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Reversible myocardial perfusion defect
- A stress image showing reduced tracer uptake that fills in on rest images; it indicates stress-induced ischemia rather than scarred myocardium.
- V/Q mismatch
- A perfusion defect with normal ventilation on lung scintigraphy; it raises suspicion for pulmonary embolism and is interpreted with clinical probability and chest imaging.
- Three-phase bone scan
- Dynamic flow, blood-pool, and delayed images after Tc-99m MDP; the sequence separates hyperemia from osteoblastic uptake and helps evaluate infection, fracture, or complex regional pain.
- Hepatobiliary nonvisualization
- Absence of gallbladder activity several hours after Tc-99m hepatobiliary tracer, especially with morphine augmentation, suggests acute cholecystitis when liver and bowel activity are present.
- Meckel diverticulum scan
- Tc-99m pertechnetate uptake in ectopic gastric mucosa in the right lower abdomen; it supports a Meckel diverticulum diagnosis, though other gastric or inflammatory lesions can mimic it.
- Captopril renogram
- Renal scintigraphy performed with an ACE inhibitor; a fall in relative function or prolongation of parenchymal transit suggests renovascular hypertension from unilateral renal artery stenosis.
- Sentinel lymph node mapping
- Injection of a radiolabeled colloid or tilmanocept near a tumor, followed by lymphoscintigraphy and gamma probe detection to identify the first draining nodes for biopsy.
- Mo-99 breakthrough limit
- The allowable Mo-99 activity in Tc-99m eluate is 0.15 kBq per MBq (0.15 µCi per mCi) of Tc-99m; exceeding it requires the eluate to be discarded.
- Aluminum breakthrough
- Alumina from a Tc-99m generator can appear in eluate; the limit is 10 µg/mL, and excess aluminum may cause particle aggregation and altered biodistribution.
- Radiochemical purity
- The fraction of total radioactivity present in the desired chemical form; it is measured by chromatography and must meet the package insert before a radiopharmaceutical is administered.
- F-18 FDG half-life
- Fluorine-18 has a 110-minute physical half-life; this limits shipping range and requires decay correction for dose calibration and PET scheduling.
- MAA particle size
- Technetium-99m macroaggregated albumin particles are typically 10 to 90 µm; they lodge in pulmonary capillaries after intravenous injection and must not be injected if clumped.
- I-131 decay time
- Iodine-131 has an 8.02-day half-life, so radioactive waste and patient precautions require decay through about 10 half-lives, or roughly 80 days, before release.
- Photopeak energy window
- A pulse-height analyzer accepts counts within a chosen energy range; for Tc-99m the 140-keV photopeak is commonly windowed at about ±10%, or 126 to 154 keV.
- Center of rotation
- The axis about which a gamma camera rotates during SPECT; misalignment produces ring or arc artifacts, so it is measured and corrected on a regular QC schedule.
- Parallel-hole collimator
- A collimator with parallel channels that preserves image size, increases resolution as hole length increases, and reduces sensitivity as septal thickness and hole length increase.
- PET coincidence detection
- Two 511-keV annihilation photons detected within a short timing window define an event; true coincidences localize the source, while scatter and random coincidences add background.
- CT Hounsfield unit
- A scaled CT attenuation value with water at 0 HU and air near -1000 HU; it allows tissue characterization and is used for attenuation correction in PET/CT.
- Dead time
- The interval after a detector event when the system cannot register another pulse; high activity causes count loss and can distort quantitation, especially in PET and first-pass studies.
- Matrix and pixel size
- Digital image dimensions define pixel size as field of view divided by matrix width; a larger matrix gives smaller pixels and finer display, but counts per pixel decrease.
- Inverse square law
- Radiation intensity from a point source varies inversely with the square of distance; doubling distance reduces exposure rate to one quarter of its original value.
- Occupational dose limit
- The annual effective dose limit for radiation workers is 50 mSv (5 rem), with a lens limit of 150 mSv and a skin or extremity limit of 500 mSv.
- Fetal dose limit
- After a worker declares pregnancy, the embryo-fetus dose limit is 0.5 mSv per month and 5 mSv over the entire gestation, with ALARA review of duties.
- HVL lead for Tc-99m
- The half-value layer of lead for Tc-99m gamma rays is about 0.3 mm; typical 0.5-mm lead aprons therefore attenuate a substantial but not complete fraction.
- Radioactive waste decay
- Short-lived waste is held for about 10 half-lives before release; Tc-99m requires roughly 60 hours, while I-131 requires about 80 days.
- Contamination survey meter
- A thin-window Geiger-Mueller or scintillation detector is used to find removable contamination; wipes are counted for gamma emitters and documented against release criteria.
- Two-identifier patient check
- Before radiopharmaceutical administration, staff verify at least two patient identifiers, such as name and date of birth, and match the dose label to the order.
- Dose calibrator constancy
- A daily check with a long-lived source verifies that the dose calibrator response is stable; accuracy, linearity, and geometry tests are performed on their own schedules.
- Gamma camera uniformity QC
- A daily flood image tests detector uniformity; nonuniformity appears as hot or cold spots and can produce ring artifacts, so corrections are applied before clinical imaging.
- Breastfeeding after radiopharmaceutical
- Lactating patients may need to interrupt breastfeeding and pump-and-discard for a period determined by the radiopharmaceutical, activity, and lactation guidance.
- Extravasation response
- If injection infiltrates, stop administration, estimate retained activity, apply local measures per protocol, document the event, and notify the authorized user and patient.
- Renal function before contrast
- Assess eGFR or creatinine when iodinated contrast or nephrotoxic drugs are planned; hydration and protocol adjustment reduce the risk of contrast-associated kidney injury.