Cross-connection

Any actual or potential link between a potable water supply and a source of contamination or pollution, allowing used or unsafe water to flow back into the drinking water system.

Related: Backflow, Air gap
Backflow

The unwanted reversal of normal water flow direction in a piping system, carrying nonpotable water or other substances toward the potable supply.

Related: Backsiphonage, Backpressure, Cross-connection
Backsiphonage

Backflow caused by negative or sub-atmospheric pressure in the supply piping, which draws nonpotable liquid into the potable system through a cross-connection.

Related: Backflow, Backpressure, Vacuum breaker
Backpressure

Backflow caused when downstream pressure exceeds the pressure of the potable supply, pushing nonpotable water backward into the drinking water piping.

Related: Backflow, Backsiphonage, Reduced pressure principle assembly
Pollution

The presence in water of any substance that degrades its quality or appearance but does not necessarily create an immediate health hazard to consumers.

Related: Contamination, Hazard classification
Contamination

The introduction of any substance into potable water that creates an actual hazard to public health, such as sewage, toxic chemicals, or disease-causing organisms.

Related: Pollution, Hazard classification, Health hazard
Health hazard

A cross-connection condition capable of introducing contaminants that cause illness, injury, or death, requiring the highest level of protection.

Related: Contamination, Non-health hazard, Hazard classification
Non-health hazard

A cross-connection condition that could degrade water quality or aesthetics but is unlikely to cause sickness or injury, such as a low-toxicity pollutant.

Related: Health hazard, Pollution, Hazard classification
Hazard classification

The systematic process of rating the degree of risk a cross-connection poses, typically as health or non-health hazard, to determine the protection required.

Related: Health hazard, Non-health hazard, Premises isolation
Air gap

A physical separation between a potable water outlet and the flood level rim of a receiving vessel, providing the highest degree of backflow protection.

Related: Flood level rim, Reduced pressure principle assembly, Cross-connection
Flood level rim

The lowest edge of the opening of a fixture or receptacle through which water would overflow, used as the reference point for measuring an air gap.

Related: Air gap, Vacuum breaker
Reduced pressure principle assembly

A testable assembly with two spring-loaded check valves and a hydraulically operated relief valve, providing protection against both backpressure and backsiphonage health hazards.

Related: Check valve, Relief valve, Air gap
Double check valve assembly

A testable assembly of two independently acting check valves used to protect against non-health hazards from both backpressure and backsiphonage.

Related: Check valve, Reduced pressure principle assembly, Non-health hazard
Pressure vacuum breaker assembly

A testable device with a loaded check valve and an independent air inlet valve that opens at low pressure, protecting against backsiphonage only.

Related: Atmospheric vacuum breaker, Backsiphonage, Spill-resistant vacuum breaker
Atmospheric vacuum breaker

A non-testable device with a check valve and an air inlet that opens at atmospheric pressure, used where backpressure cannot occur.

Related: Pressure vacuum breaker assembly, Backsiphonage, Vacuum breaker
Spill-resistant vacuum breaker

A testable assembly combining a check valve and an air inlet that opens only during backsiphonage, allowing installation where a standard vacuum breaker would spill water.

Related: Pressure vacuum breaker assembly, Backsiphonage
Check valve

A valve that allows water to flow in one direction only, closing automatically to prevent reverse flow within an assembly or device.

Related: Reduced pressure principle assembly, Double check valve assembly
Relief valve

The hydraulically operated component of a reduced pressure principle assembly that discharges water to drain when a fault allows the pressure differential to reverse.

Related: Reduced pressure principle assembly, Check valve
Vacuum breaker

A device that admits air into piping when internal pressure drops below atmospheric, breaking the siphon that would otherwise cause backsiphonage.

Related: Backsiphonage, Atmospheric vacuum breaker, Pressure vacuum breaker assembly
Premises isolation

Protecting a water utility's distribution system from hazards on a customer's property by installing a containment assembly at the service connection.

Related: Containment assembly, Internal protection, Service connection
Internal protection

Backflow prevention installed at individual fixtures, appliances, or processes within a building, addressing specific hazards that premises isolation alone cannot cover.

Related: Premises isolation, Fixture protection, Hazard assessment
Containment assembly

The backflow prevention assembly installed at the meter or service connection to isolate the entire premises from the public water system.

Related: Premises isolation, Service connection
Hazard assessment

A structured survey of a facility's plumbing and processes to identify cross-connections, rate their risk, and determine appropriate protection methods.

Related: Hazard classification, Internal protection, Cross-connection survey
Cross-connection survey

An on-site inspection of a premises that documents water uses, cross-connections, and existing protection to support program decisions and compliance tracking.

Related: Hazard assessment, Premises isolation
Service connection

The point where a customer's private plumbing connects to the public water distribution main, typically the location for containment protection and metering.

Related: Containment assembly, Premises isolation
Field test

A documented on-site procedure that measures the performance of a backflow assembly's check valves and relief valve against established pass/fail criteria.

Related: Differential pressure, Test report, Certified tester
Differential pressure

The measured pressure difference across a check valve or relief valve, used in field testing to confirm the assembly opens and closes within acceptable limits.

Related: Field test, Relief valve
Certified tester

A person who has completed recognized training and testing and holds current credentials authorizing them to test backflow prevention assemblies.

Related: Field test, Test report
Test report

A standardized record of assembly test results, including pressures, pass or fail status, tester identity, and date, submitted to the water authority.

Related: Field test, Certified tester, Recordkeeping
Recordkeeping

The organized maintenance of cross-connection program data such as surveys, test reports, permits, and repair histories for retrieval and audit.

Related: Test report, Program evaluation
Program evaluation

Periodic review of a cross-connection control program's coverage, compliance rates, and outcomes to identify gaps and guide improvements.

Related: Recordkeeping, Cross-connection survey
Annual testing requirement

The regulatory obligation for owners of testable backflow assemblies to have them tested at least yearly by a certified tester and submit results.

Related: Field test, Test report, Certified tester
Thermal expansion

Pressure buildup in a closed plumbing system as heated water expands, which can damage components and must be addressed when backflow protection closes the system.

Related: Check valve, Relief valve
Authority having jurisdiction

The agency or official responsible for enforcing cross-connection control rules, approving assemblies, and requiring corrections within its area.

Related: Regulation, Premises isolation
Regulation

A legally binding rule adopted by a government body that sets cross-connection control requirements, enforcement powers, and penalties within its scope.

Related: Authority having jurisdiction, Standard
Standard

A consensus technical document that specifies assembly design, performance, and testing criteria, often referenced by codes and regulations.

Related: Regulation, Field test
Fixture protection

The use of a device such as an air gap or vacuum breaker at an individual fixture or appliance to prevent backflow at that point of use.

Related: Internal protection, Air gap, Vacuum breaker
Degree of hazard

The severity of risk a cross-connection presents, ranging from low to high, used to match the type of backflow protection to the situation.

Related: Hazard classification, Health hazard, Non-health hazard