QLD Electrical Licence study materials
QLD Electrical Licence study resources

QLD Electrical Licence flashcards

QLD Electrical Licence · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Ohm's law
For a resistive circuit, voltage equals current multiplied by resistance; current equals voltage divided by resistance; resistance equals voltage divided by current.
Electrical power formula
Power in a DC or resistive circuit equals voltage times current; also current squared times resistance or voltage squared divided by resistance.
Three-phase power
For a balanced three-phase load, real power equals the square root of three times line voltage times line current times power factor.
Impedance
Total opposition to alternating current, combining resistance and reactance; calculated as the square root of resistance squared plus reactance squared.
Series circuit
A circuit with one current path; the same current flows through all components and total resistance is the sum of individual resistances.
Parallel circuit
A circuit with multiple current paths; voltage is the same across each branch and total resistance is found from the reciprocal sum.
MEN system
Multiple earthed neutral system used in Australia; the neutral and protective earth are connected at the point of supply only, then separated throughout the installation.
Protective earthing
Connection of exposed conductive parts to the earthing system so fault current returns to source and protective devices operate to disconnect supply.
Voltage drop limit
AS/NZS 3000 generally limits voltage drop from the point of supply to any point of an LV installation to 5 percent of nominal voltage.
RCD 30 mA
Residual current device with maximum rated residual current of 30 milliamps, required by AS/NZS 3000 for specified final subcircuits to reduce electric shock risk.
IP rating
Ingress protection code; first digit indicates protection against solids and dust, second digit indicates protection against water, with higher numbers giving greater protection.
Maximum demand
The greatest load an installation is expected to draw, calculated using diversity and AS/NZS 3000 methods rather than simply adding all connected loads.
Circuit segregation
Separation of electrical, communications and data cables to prevent interference and unsafe contact; required by AS/NZS 3000 and communications standards.
Electrical Safety Act 2002
Queensland legislation imposing duties on PCBUs and others to ensure electrical safety and eliminate or minimise electrical risks to people and property.
Electrical Safety Regulation 2013
Queensland regulation supporting the Electrical Safety Act, covering licensing, safety requirements, testing, and adoption of AS/NZS 3000.
Electrical Safety Office
Queensland regulator administering electrical safety legislation, licensing, investigations, and compliance, often called the ESO.
Electrical contractor licence
Queensland licence required for a business to carry out electrical contracting work; individual electrical workers also need the appropriate worker licence.
Primary duty of PCBU
A person conducting a business or undertaking must ensure, so far as reasonably practicable, the health and safety of workers and others affected by the business.
Incident notification
Serious electrical incidents and dangerous events must be reported to the Electrical Safety Office or WorkSafe Queensland under Queensland safety laws.
Insulation resistance test
Test using an insulation tester at 500 volts DC with installation isolated; LV circuits should generally achieve at least 1 megohm.
Continuity test
Low-resistance test confirming protective earthing conductors and bonding connect exposed conductive parts to the earth bar.
Polarity test
Verification that active conductors are switched and connected correctly, neutrals are not switched, and socket outlets are wired to correct terminals.
Earth fault loop impedance
Impedance of the fault current path; must be low enough for the protective device to disconnect within the required time.
RCD trip test
Operational test of a residual current device using a tester to confirm it trips at its rated residual current and within the required time.
Test for dead
Confirming a circuit is de-energised using a proven voltage tester, checking all conductors and proving the tester before and after.
Visual inspection
Pre-test check of connections, enclosures, labels, damage, earthing, and IP integrity before electrical testing and energisation.
Hierarchy of control
Risk control order: eliminate the hazard, substitute, use engineering controls, then administrative controls, with personal protective equipment as the last resort.
Lock out tag out
Isolation procedure using locks and tags to prevent unexpected energisation while electrical work or maintenance is being performed.
Arc flash
Dangerous release of energy from an electrical arc, causing intense heat, light, pressure, and molten metal; avoid energised work and use arc-rated PPE.
SWMS
Safe work method statement; document identifying high-risk work hazards, control measures, and responsibilities before work starts.
Electric shock response
Isolate supply, call emergency services, start CPR and use a defibrillator if trained; do not touch the person until supply is isolated.
Prove test instrument
Check the voltage tester on a known live source before and after testing to confirm it is functioning and the circuit is actually dead.