QLD Electrical Licence study plan
QLD Electrical Licence · Give each week a clear focus.
8 weeks · About 7 hours per week
Electrical theory and fundamentals
Solve 30 mixed Ohm's law, power, and series/parallel circuit problems, showing full working for each
Calculate equivalent resistance, branch currents, and voltage drops for 10 multi-resistor networks without reference notes
Explain RMS, peak, average, frequency, phase difference, and reactance in your own written words with a worked example of each
Convert confidently between unit prefixes (micro through mega) and between W, kW, VA, and kVA across 20 conversion drills
Your checkpoint
Closed-book theory quiz of 30 questions scored at 80% or better, with a written correction note for every item missed
Electrical theory and fundamentals & Wiring Rules and installation standards (AS/NZS 3000)
Calculate voltage drop and current-carrying capacity for 5 representative domestic and light-commercial circuits
Apply power factor to convert between kW and kVA and select a supply capacity for 3 given load schedules
Map the structure and section headings of AS/NZS 3000 and locate the governing clause for 15 written installation scenarios
Memorise and reproduce the defined terms most used in the standard (e.g. final subcircuit, main earthing conductor, protective earthing) from memory
Your checkpoint
A one-page clause index map of AS/NZS 3000 plus a log of 15 scenario-to-clause lookups with the clause number and a one-line justification for each
Wiring Rules and installation standards (AS/NZS 3000)
Describe the MEN earthing arrangement, its purpose, and the earthing requirements for an installation in a written explanation
Select protective device type, rating, and breaking capacity for 6 given load and fault-level scenarios and justify each choice
Perform maximum demand calculations for 3 sample installations using the standard's methods and record the resulting main and subcircuit sizing
Assign correct IP ratings and wiring methods to 8 stated locations, including damp, outdoor, and confined areas
Apply the additional requirements for special locations (bathrooms, pools, construction sites) to 5 short case descriptions
Your checkpoint
Completed maximum demand and protection selection worksheet for 3 sample installations, including derating factors and a final cable schedule for each
Wiring Rules and installation standards (AS/NZS 3000) & Queensland electrical safety legislation and regulatory requirements
Apply acceptable construction requirements for support, fixing, segregation, and identification of wiring systems across 10 inspection-style scenarios
Apply derating factors (temperature, grouping, thermal insulation) to recalculate cable size for 4 installations
Outline the duties imposed on a person conducting a business or undertaking and on workers under Queensland electrical safety legislation
Distinguish the Queensland licence classes and state which class may lawfully perform 8 listed tasks
Summarise the regulator's role in licensing, compliance auditing, and enforcement in a one-page flow
Your checkpoint
Timed 40-question mixed quiz on wiring rules and Queensland legislation, scored at 75% or better with a written correction log
Queensland electrical safety legislation and regulatory requirements
Classify 10 incident descriptions as notifiable or non-notifiable and state the reporting obligation and timeframe for each
Explain how the Wiring Rules are given legal effect through Queensland regulation and what that means for a licensed worker
Describe the testing-and-verification obligations, record-keeping, and certification duties imposed by legislation for 5 job types
Outline the process and consequences of an electrical compliance inspection, defect notice, and disciplinary action
List the required content of an electrical safety management arrangement for a small contracting business
Your checkpoint
A 40-question legislation quiz scored at 85% or better, plus a one-page duty-of-care and incident-reporting flowchart drawn from memory
Installation practice, testing and verification
Sequence and describe the procedures for continuity, insulation resistance, polarity, earth fault loop impedance, and RCD trip-time testing, including instrument checks before and after each test
Calculate expected earth fault loop impedance for 4 circuits and compare the result against the maximum permitted value
Determine pass or fail for 12 supplied test results and state the corrective action for each failure
Complete a visual inspection checklist covering 15 specified items for a sample installation
Complete a Certificate of Test-style record with all required fields, signatures, and declared results
Your checkpoint
A full simulated test-and-commissioning pack for one installation, with every recorded result compared against its limit and each non-compliance annotated with the required rectification
Electrical safety, risk control and safe work practices & Installation practice, testing and verification
Draft three safe work method statements covering a switchboard replacement, a roof-space cable run, and energised diagnostic testing
Apply the hierarchy of risk control to rank and justify controls for 8 identified electrical hazards
Describe isolation, lock-out/tag-out, prove-dead, and tag-and-test procedures in correct order for 3 work scenarios
Specify hazard controls for arc flash, working at height, asbestos-containing materials, and confined spaces in 4 short written responses
Select, inspect, and state the pre-use checks for PPE and test instruments appropriate to 5 task types
Your checkpoint
Three complete safe work method statements with risk matrices, control measures mapped to the hierarchy of control, and a pre-use inspection record for test equipment
Electrical theory and fundamentals & Wiring Rules and installation standards (AS/NZS 3000) & Queensland electrical safety legislation and regulatory requirements & Installation practice, testing and verification & Electrical safety, risk control and safe work practices
Complete two full-length timed practice exams under exam conditions and record the score for each domain separately
Re-solve every missed question and write the underlying rule, value, or clause for each one
Reproduce from memory a single-page sheet of key figures: clearances, test limits, device ratings, and statutory timeframes
Rehearse completing a Certificate of Test and an incident notification from blank templates within time limits
Your checkpoint
Final mock exam scored at 80% or better overall with at least 75% in every domain, plus a from-memory one-page formula and limits sheet
Milestones
Week 2: Can solve circuit and voltage drop calculations closed-book and can locate the governing clause for 12 of 15 random scenarios within 2 minutes each
Week 4: Scores 75% or better on the mixed wiring rules and legislation quiz, and correctly names the licence class required for 7 of 8 task descriptions
Week 6: Passes the simulated commissioning pack: all test results judged correctly against limits and the Certificate of Test completed with no missing mandatory fields
Week 8: Achieves 80% or better overall and 75% or better in each of the five domains on the final timed mock exam