BTEB Electrician (EIM) Exam key terms
BTEB Electrician (EIM) Exam · Get comfortable with the vocabulary.
- Lockout/Tagout (LOTO)
- Related: Isolation, Proving Dead
A safety procedure in which the power source is switched off, isolated, locked, and tagged so equipment cannot be re-energised while someone works on it.
- Proving Dead
- Related: Lockout/Tagout (LOTO), Isolation
Confirming with a tested voltage detector that a circuit or conductor carries no voltage before work begins or before earthing is applied.
- Isolation
- Related: Lockout/Tagout (LOTO), Proving Dead
Physically separating a circuit or equipment from every source of supply so that it cannot become live during maintenance or repair work.
- Ohm's Law
- Related: Power Formula, Resistance
The relationship stating that voltage equals current multiplied by resistance, written V = I × R, used to calculate any one value when the other two are known.
- Power Formula
- Related: Ohm's Law, Power Factor
The relationship for electrical power, P = V × I, with related forms P = I²R and P = V²/R, used to size circuits and check loading.
- Power Factor
- Related: Power Formula, Inductance
The ratio of true power in watts to apparent power in volt-amperes in an AC circuit, equal to the cosine of the phase angle between voltage and current.
- Resistance
- Related: Ohm's Law, Resistivity
The property of a material that opposes the flow of electric current, measured in ohms and depending on material, length, and cross-sectional area.
- Resistivity
- Related: Resistance, Voltage Drop
A material constant showing how strongly a substance resists current flow per unit length and area, used to calculate conductor resistance from its dimensions.
- Voltage Drop
- Related: Resistivity, Cable Current Rating
The loss of voltage along a conductor caused by its resistance when current flows, which must be kept within permitted limits for proper equipment operation.
- Inductance
- Related: Power Factor, Capacitance
The property of a coil or circuit that opposes changes in current by producing a counter electromotive force, measured in henries.
- Capacitance
- Related: Inductance, Power Factor
The ability of two separated conductors to store electric charge when a voltage is applied, measured in farads and used in power-factor correction.
- Three-Phase Supply
- Related: Star-Delta Connection, Power Factor
An AC supply of three voltages equal in magnitude and 120 electrical degrees apart, used for motors and heavy loads because it gives smoother power delivery.
- Star-Delta Connection
- Related: Three-Phase Supply, Star-Delta Starter
Two ways of connecting three-phase windings: star joins one end of each winding at a neutral point, while delta connects them end to end in a loop.
- Cable Current Rating
- Related: Voltage Drop, Derating Factor
The maximum current a cable can carry continuously without its insulation exceeding its permitted temperature, given installation method and ambient conditions.
- Derating Factor
- Related: Cable Current Rating, Diversity Factor
A multiplier below one applied to a cable's tabulated current rating to allow for grouping, high ambient temperature, or thermal insulation around the cable.
- Diversity Factor
- Related: Derating Factor, Maximum Demand
An allowance recognising that not all connected loads operate at the same time, used to size supply cables and protective devices realistically.
- Maximum Demand
- Related: Diversity Factor, Load Schedule
The greatest load a consumer's installation is expected to draw at any one time, calculated after applying diversity to the total connected load.
- Earthing
- Related: Earth Loop Impedance, Residual Current Device
Connecting exposed conductive parts and the supply neutral point to the general mass of earth so fault current flows and protection operates quickly.
- Earth Loop Impedance
- Related: Earthing, Protective Device Discrimination
The total resistance of the path taken by fault current through the earth and back to the supply, which must be low enough to trip protection fast.
- Residual Current Device (RCD)
- Related: Earthing, Circuit Breaker
A protective device that trips when it detects a small imbalance between line and neutral current, indicating leakage to earth or through a person.
- Circuit Breaker
- Related: Fuse, Protective Device Discrimination
A switch that automatically opens a circuit on overload or short circuit and can be reset, available in miniature, moulded-case, and air types.
- Fuse
- Related: Circuit Breaker, Breaking Capacity
A protective device containing a element that melts and breaks the circuit when current exceeds its rating for a set time, then must be replaced.
- Breaking Capacity
- Related: Fuse, Circuit Breaker
The maximum fault current a protective device can safely interrupt without damage to itself or danger to the surrounding installation.
- Protective Device Discrimination
- Related: Circuit Breaker, Earth Loop Impedance
Coordination of protective devices so that the device nearest a fault operates first, leaving the rest of the installation energised.
- Contactor
- Related: Overload Relay, Interlock
An electromagnetically operated switch used to control power circuits repeatedly, holding its contacts closed while its coil stays energised.
- Overload Relay
- Related: Contactor, Direct-On-Line Starter
A protective device that senses sustained excess current in a motor circuit and opens the control circuit before the motor winding overheats.
- Interlock
- Related: Contactor, Limit Switch
A control arrangement that prevents one action unless another condition is met, such as stopping a forward contactor before reverse can energise.
- Direct-On-Line Starter
- Related: Star-Delta Starter, Overload Relay
A motor starter that connects the motor directly to the full supply voltage, giving high starting torque but drawing a large starting current.
- Star-Delta Starter
- Related: Star-Delta Connection, Direct-On-Line Starter
A starter that runs the motor windings in star during acceleration to reduce starting current, then changes to delta for normal running.
- Limit Switch
- Related: Interlock, Contactor
A switch operated by the movement of a machine part or door, used to stop travel, reverse direction, or confirm a safe position.
- Transformer
- Related: Turns Ratio, Inductance
A static device with two windings on a common magnetic core that changes AC voltage level while transferring power by electromagnetic induction.
- Turns Ratio
- Related: Transformer, Three-Phase Supply
The ratio of primary to secondary winding turns, which sets the ratio between primary and secondary voltages in a transformer.
- Insulation Resistance Test
- Related: Continuity Test, Polarity Test
A test using a high-voltage DC instrument to measure how well insulation resists leakage, expressed in megohms and compared with a minimum value.
- Continuity Test
- Related: Insulation Resistance Test, Polarity Test
A check confirming that a conductor or protective path is unbroken and has low resistance, usually made with a low-voltage ohmmeter or buzzer.
- Polarity Test
- Related: Continuity Test, Insulation Resistance Test
A verification that line, neutral, and switch connections are in the correct positions so switches control the line conductor, not the neutral.
- Two-Way Switching
- Related: Intermediate Switching, Loop-in System
A wiring arrangement using two two-way switches so a lamp can be controlled from either of two positions, such as both ends of a stairway.
- Intermediate Switching
- Related: Two-Way Switching, Loop-in System
A method adding a four-terminal intermediate switch into a two-way circuit so the same lamp can be controlled from three or more positions.
- Loop-in System
- Related: Two-Way Switching, Continuity Test
A wiring method where circuit cables run from ceiling rose to ceiling rose and switches are fed by separate drops, avoiding joints in the main run.
- Conduit
- Related: Trunking, Cable Tray
A tube of metal or plastic that carries and mechanically protects insulated conductors, either buried in walls or mounted on the surface.
- Trunking
- Related: Conduit, Cable Tray
A rectangular enclosure with a removable lid used to carry and protect cables or conductors, often surface-mounted where wiring may be altered.
- Cable Tray
- Related: Conduit, Trunking
An open metal or plastic support system carrying cables in industrial and commercial installations, allowing easy inspection and heat dissipation.
- Micrometer
- Related: Vernier Caliper, Continuity Test
A precision measuring instrument with a calibrated screw used to measure the diameter of wire or the thickness of sheet metal accurately.
- Vernier Caliper
- Related: Micrometer, Cable Gland
A measuring tool with a sliding jaw and a vernier scale used to read internal, external, and depth dimensions to a fraction of a millimetre.
- Cable Gland
- Related: Vernier Caliper, Earthing
A fitting that secures a cable where it enters an enclosure and provides strain relief, sealing, and often an earth connection to armour.
- Schematic Diagram
- Related: Wiring Diagram, Load Schedule
A drawing showing the electrical connections and function of a circuit without regard to the physical position of the components.
- Wiring Diagram
- Related: Schematic Diagram, Cable Schedule
A drawing showing components in roughly their physical positions with the connections between them, used for installation and fault finding.
- Load Schedule
- Related: Maximum Demand, Cable Schedule
A table listing each circuit, its connected load, protective device rating, and cable size, used for design and inspection documentation.
- Cable Schedule
- Related: Load Schedule, Wiring Diagram
A document listing each cable run with its type, size, route, and end points, helping installation, material take-off, and later maintenance.
- Rectifier
- Related: Inverter, Diode
A circuit or device, often using diodes, that converts alternating current into direct current for supplies, chargers, and drives.
- Inverter
- Related: Rectifier, Variable Frequency Drive
A device that converts direct current into alternating current, used in variable-speed drives, backup supplies, and solar installations.
- Diode
- Related: Rectifier, Transistor
A two-terminal semiconductor that conducts current mainly in one direction, used for rectification, protection, and freewheeling in control circuits.
- Transistor
- Related: Diode, Programmable Logic Controller
A three-terminal semiconductor used as an amplifier or an electronic switch, forming the basis of sensors, relays drivers, and control logic.
- Variable Frequency Drive
- Related: Inverter, Direct-On-Line Starter
An electronic unit that varies the frequency and voltage fed to a motor, allowing controlled speed and reduced starting current.
- Programmable Logic Controller (PLC)
- Related: Transistor, Interlock
An industrial computer that runs a stored program to read inputs and switch outputs, replacing relay logic in machine and process control.
- Personal Protective Equipment (PPE)
- Related: Lockout/Tagout (LOTO), Risk Assessment
Items worn to reduce injury risk, such as insulating gloves, safety footwear, eye protection, and arc-rated clothing, selected for the task.
- Risk Assessment
- Related: Personal Protective Equipment (PPE), Isolation
A structured review identifying hazards, judging how likely and severe harm could be, and recording controls before work starts.
- Method Statement
- Related: Risk Assessment, Load Schedule
A written description of how a job will be carried out safely, listing sequence, tools, controls, and responsible persons.