BPI Building Analyst flashcards
BPI Building Analyst · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Stack effect
- Buoyancy-driven pressure difference caused by indoor-outdoor temperature difference; warm air rises and exits high, drawing cold air in low.
- Neutral pressure level
- The height in a building where indoor and outdoor pressures are equal; above it air exfiltrates, below it air infiltrates.
- Thermal boundary
- The continuous layer of insulation separating conditioned from unconditioned space; it should align with the air barrier.
- Vapor retarder classes
- Class I below 0.1 perm, Class II 0.1 to 1.0 perm, Class III 1.0 to 10 perm; placement depends on climate and assembly.
- Blower door CFM50
- Airflow in cubic feet per minute needed to hold the house at 50 Pa pressure difference; the standard metric of envelope tightness.
- ACH50
- Air changes per hour at 50 Pa, calculated as CFM50 times 60 divided by conditioned volume in cubic feet.
- Pressure pan test
- A gauge placed over a register grille measures pressure relative to the house; readings above 1-2 Pa indicate duct leakage.
- Duct leakage CFM25
- Duct airflow measured at 25 Pa reference pressure with registers sealed; reported as a percentage of total system airflow.
- Grade I insulation
- Insulation installed in full contact on all six sides with no gaps or compression, delivering the nominal R-value.
- Rim joist sealing
- The band joist at the floor perimeter is a major air leakage path and should be sealed and insulated to wall R-value.
- Attic baffles
- Rigid channels that keep a one-inch ventilation path at the roof deck and prevent insulation from blocking soffit vents.
- Manual J
- ACCA method for calculating residential heating and cooling loads from envelope, infiltration, and internal gain inputs.
- Sensible heat ratio
- Sensible capacity divided by total capacity; oversizing raises SHR and reduces latent moisture removal.
- Subcooling method
- Charge verification for TXV systems; measured liquid-line temperature minus saturation temperature, typically 8-12 degrees F.
- External static pressure
- Total pressure resistance of the duct system and filter, measured in inches of water column; keep below about 0.5 in. w.c.
- Air-free CO
- Measured CO multiplied by 20.9 divided by 20.9 minus measured O2; normalizes flue CO to zero excess air.
- Worst-case depressurization
- Test that runs all exhaust fans and dryers with doors closed, then verifies combustion appliance draft remains within specification.
- ASHRAE 62.2 rate
- Whole-house ventilation formula: 0.03 times floor area plus 7.5 times bedrooms plus one, in CFM.
- Spillage
- Flue gases escaping into the living space instead of up the vent; indicates failed draft and requires appliance shutdown.
- Degree-day method
- Estimates annual energy from UA, heating degree days, and efficiency; assumes a 65 degree F balance point by convention.
- Model calibration
- Adjusting model inputs so predicted consumption matches at least 12 months of utility data within about plus or minus 5 percent.
- Simple payback
- Installed measure cost divided by annual energy savings; ignores measure life, financing, and fuel escalation.
- Interactive effects
- When one measure changes the savings of another, so savings cannot be summed linearly across a retrofit package.
- Savings-to-investment ratio
- Present value of lifetime savings divided by installed cost; a ratio above 1.0 indicates a cost-effective measure.
- Test-in and test-out
- Baseline diagnostic measurements taken before work and repeated after, used to verify performance improvement.
- Change order
- Written authorization for work outside the original scope, signed by the client before the additional work proceeds.
- Sensible heat equation
- Q equals 1.08 times CFM times temperature difference in degrees F, giving Btu per hour for air at standard conditions.
- Latent heat equation
- Q equals 0.68 times CFM times humidity ratio difference in grains per pound, giving Btu per hour of latent load.
- Psychrometric chart
- Graph of air properties including dry-bulb, wet-bulb, dew point, humidity ratio, and enthalpy at a given pressure.
- Thermal bridging
- Heat flow through framing members that bypasses insulation, reducing whole-assembly R-value below the cavity value.
- Effective leakage area
- Estimated equivalent hole size in square inches at 4 Pa, often approximated as CFM50 divided by 18 for homes.
- Leakage curve exponent
- The exponent n in Q equals C times pressure to the n; residential values typically fall between 0.6 and 0.75.