LTP12 key terms
LTP12 · Get comfortable with the vocabulary.
- Standard precautions
- Related: Biosafety level, Exposure control plan, Sharps injury
Infection-control practices applied to every patient specimen regardless of known diagnosis, including hand hygiene, gloves, gowns, eye protection, and safe handling of sharps and contaminated waste.
- Biosafety level
- Related: Standard precautions, Primary containment
A graded set of containment requirements, from BSL-1 through BSL-4, specifying facility design, equipment, and work practices needed to safely handle organisms of increasing hazard.
- Primary containment
- Related: Biosafety level, Biological safety cabinet
Protection of the worker and immediate laboratory environment from infectious agents, achieved through good technique, personal protective equipment, and biological safety cabinets.
- Biological safety cabinet
- Related: Primary containment, Aerosol generation
A ventilated enclosure that uses directional airflow and HEPA filtration to protect the operator, the sample, or both from aerosols generated during handling of infectious or sterile materials.
- Aerosol generation
- Related: Biological safety cabinet, Standard precautions
Formation of fine airborne droplets or particles from actions such as uncapping tubes, pipetting, centrifuging, or flaming loops, which can carry infectious agents into the breathing zone.
- Sharps injury
- Related: Exposure control plan, Standard precautions
A percutaneous injury from a needle, lancet, blade, or broken glass that can transmit bloodborne pathogens, requiring immediate first aid, reporting, and source evaluation.
- Exposure control plan
- Related: Sharps injury, Standard precautions
A written program describing how a laboratory identifies, prevents, and responds to occupational exposure to bloodborne and other infectious agents, including training and post-exposure follow-up.
- Chemical hygiene plan
- Related: Safety data sheet, Secondary containment
A documented set of laboratory-specific policies and procedures for safe use, storage, and disposal of hazardous chemicals, including engineering controls and required training.
- Safety data sheet
- Related: Chemical hygiene plan, Secondary containment
A standardized document listing a chemical's hazards, handling precautions, first-aid measures, and spill response, which must be accessible to anyone working with that substance.
- Secondary containment
- Related: Chemical hygiene plan, Safety data sheet
A tray, cabinet, or barrier placed beneath chemical or biological containers to capture leaks and spills, preventing spread to the work surface, floor, or drainage system.
- Patient identification
- Related: Specimen labeling, Wrong blood in tube
Verification that the specimen and its container belong to the correct person, typically using at least two independent identifiers at collection and again before any testing or result release.
- Specimen labeling
- Related: Patient identification, Chain of custody
Applying accurate, legible identifiers and collection details to a container at the bedside or collection site, enabling traceability from patient to result and preventing misattribution.
- Chain of custody
- Related: Specimen labeling, Specimen rejection criteria
A documented, unbroken record of who collected, handled, stored, and transported a specimen, used when legal or forensic defensibility of results is required.
- Specimen rejection criteria
- Related: Patient identification, Hemolysis interference
Predefined conditions such as mislabeling, insufficient volume, wrong tube, hemolysis, or delayed transport that require a specimen to be refused or recollected because results would be unreliable.
- Order of draw
- Related: Additive carryover, Tourniquet time
The prescribed sequence for filling blood collection tubes so that additive carryover between tubes does not contaminate later specimens and invalidate test results.
- Additive carryover
- Related: Order of draw, Specimen rejection criteria
Transfer of an additive such as EDTA or heparin from one collection tube into the next through the needle, potentially distorting electrolyte or coagulation results.
- Tourniquet time
- Related: Hemoconcentration, Order of draw
The interval a constricting band remains on the arm during venipuncture; prolonged application concentrates proteins and cells and alters potassium, lactate, and other analyte values.
- Hemoconcentration
- Related: Tourniquet time, Hemolysis interference
An increase in the concentration of large molecules and cells in blood caused by prolonged venous stasis, dehydration, or excessive tourniquet time, falsely elevating some analytes.
- Hemolysis interference
- Related: Hemoconcentration, Specimen rejection criteria
Release of intracellular contents from ruptured red cells that falsely raises potassium, lactate dehydrogenase, and other analytes and can also interfere optically with measurement.
- Analytical sensitivity
- Related: Limit of detection, Analytical specificity
The ability of a method to detect small amounts of an analyte, usually expressed as the lowest concentration distinguishable from zero with acceptable precision.
- Analytical specificity
- Related: Interference, Analytical sensitivity
The ability of a method to measure only the intended analyte without interference from structurally similar substances, metabolites, drugs, or matrix components present in the sample.
- Limit of detection
- Related: Analytical sensitivity, Limit of quantitation
The lowest analyte concentration that can be reliably distinguished from a blank with a stated probability of error, typically estimated from replicate measurements of low-level samples.
- Limit of quantitation
- Related: Limit of detection, Analytical measurement range
The lowest analyte concentration that can be measured with acceptable precision and bias, defining the lower end of the reportable analytical measurement range.
- Analytical measurement range
- Related: Limit of quantitation, Linearity
The span of concentrations over which a method produces results meeting defined accuracy and precision goals without dilution, verified during method validation or verification.
- Linearity
- Related: Analytical measurement range, Calibration curve
The degree to which measured values remain proportional to true analyte concentration across a range, assessed by testing diluted or spiked samples and evaluating deviation from a straight line.
- Method validation
- Related: Method verification, Analytical specificity
Establishing, through documented studies, that a new or modified method performs adequately for its intended use, covering accuracy, precision, sensitivity, specificity, and interference.
- Method verification
- Related: Method validation, Analytical measurement range
Confirming that a method already validated elsewhere meets the laboratory's performance claims, typically by checking precision, accuracy, and reportable range with the local system.
- Calibration curve
- Related: Calibrator, Linearity
A mathematical relationship derived from measuring calibrators of known concentration, used to convert instrument signal into an analyte concentration for unknown samples.
- Calibrator
- Related: Calibration curve, Control material
A material of assigned analyte concentration used to establish or adjust the instrument response function, differing from control material because its values define the measurement scale.
- Control material
- Related: Calibrator, Levey-Jennings chart
A sample with known target values run alongside patient specimens to monitor whether a measuring system remains stable and within established acceptance limits.
- Levey-Jennings chart
- Related: Westgard rules, Control material
A control chart plotting quality control results over time against mean and standard deviation limits, making shifts, trends, and random error visually apparent.
- Westgard rules
- Related: Levey-Jennings chart, Random error
A set of statistical decision criteria, such as 1-3s and 2-2s, applied to control results to decide whether an analytical run should be accepted or rejected.
- Random error
- Related: Systematic error, Westgard rules
Imprecision that varies unpredictably in direction and magnitude between replicate measurements, widening the distribution of results without shifting the mean.
- Systematic error
- Related: Random error, Bias
A consistent deviation of results from the true value in one direction, caused by calibration bias, reagent problems, or interference, and detectable as a shift in control values.
- Proficiency testing
- Related: External quality assessment, Bias
Periodic blinded challenge with externally supplied samples of unknown value, comparing a laboratory's results with peer groups to demonstrate ongoing analytical competence.
- External quality assessment
- Related: Proficiency testing, Systematic error
An interlaboratory program that distributes samples for analysis and reports comparative performance, supporting accreditation and identification of systematic problems.
- Bias
- Related: Systematic error, Recovery study
The difference between the average measured value and an accepted reference or true value, reflecting systematic rather than random deviation of a method.
- Recovery study
- Related: Bias, Interference
An experiment in which a known amount of analyte is added to a sample matrix and the measured increase is compared with the amount added to estimate bias.
- Interference
- Related: Analytical specificity, Hemolysis interference
An effect from a substance or condition in the sample, such as a drug, hemoglobin, lipid, or bilirubin, that alters the measured result independently of the analyte concentration.
- Reference interval
- Related: Reference population, Delta check
The central range of results, usually covering 95 percent of a defined healthy reference population, used to interpret whether a patient value is typical or unusual.
- Reference population
- Related: Reference interval, Delta check
A carefully characterized group of apparently healthy individuals whose test results are used to derive reference intervals, matched to the patient population as closely as possible.
- Delta check
- Related: Reference interval, Critical value
Comparison of a current result with a patient's previous value to flag unexpectedly large changes that may indicate specimen mix-up, collection error, or a genuine clinical change.
- Critical value
- Related: Delta check, Result verification
A result so far outside expected limits that it suggests imminent danger to the patient and requires immediate documented notification of a responsible caregiver.
- Result verification
- Related: Critical value, Delta check
The review step confirming that a result is analytically valid, consistent with specimen quality and prior data, and appropriate for release before it reaches the medical record.
- Autoverification
- Related: Result verification, Delta check
Rules-based software release of results that pass defined analytical and plausibility checks without manual review, with failures routed to a technologist for individual assessment.
- Corrective action
- Related: Root cause analysis, Nonconformity
A documented step taken to eliminate the cause of a detected nonconformity so it does not recur, distinguished from immediate remedial correction of the problem itself.
- Root cause analysis
- Related: Corrective action, Nonconformity
A structured investigation, using tools such as the five whys or cause-and-effect diagrams, that identifies the underlying system failures producing an error rather than blaming an individual.
- Nonconformity
- Related: Corrective action, Root cause analysis
A failure to meet a specified requirement, whether in testing, documentation, or process performance, which must be recorded, evaluated, and resolved under the quality system.
- Wrong blood in tube
- Related: Patient identification, Delta check
A mislabeled or miscollected specimen in which the blood in the tube does not belong to the named patient, a serious error usually detected by discrepant repeat or historical results.
- Competency assessment
- Related: Standard operating procedure, Document control
Documented evaluation, performed before independent testing and at defined intervals, that staff can correctly perform assigned methods, including sample handling, instrument operation, and result reporting.
- Standard operating procedure
- Related: Document control, Competency assessment
A written, approved instruction describing exactly how a task is performed, including materials, steps, acceptance criteria, and documentation, so that execution is consistent across staff.
- Document control
- Related: Standard operating procedure, Competency assessment
The system ensuring that only current, approved versions of procedures and forms are in use, with revision history, controlled distribution, and removal of obsolete copies.
- Turnaround time
- Related: Result verification, Specimen rejection criteria
The elapsed interval from specimen receipt or order entry to result availability, monitored as a key performance indicator of laboratory service and workflow efficiency.