Annular velocity
The upward speed of drilling fluid in the space between the drill pipe and borehole wall; it must exceed cuttings settling velocity to lift rock fragments out of the hole.
Lost circulation
A condition where drilling fluid escapes into a permeable or fractured formation instead of returning to the surface, causing falling fluid levels and reduced hole cleaning.
Cable-tool drilling
A percussion method in which a heavy bit is raised and dropped to crush rock; the hole is periodically bailed to remove cuttings and slurry.
Rotary drilling
A method using a rotating bit turned by a drill string, with circulating fluid or air removing cuttings; it is fast in consolidated rock and requires mud management.
Filter pack sizing
Gravel envelope placed around a screen, sized about four to six times the formation D50 for uniform sand, so formation fines pass while coarser particles are retained.
Well screen open area
The total slot or perforation area of a screen; it should be large enough to keep entrance velocity low and reduce head loss during pumping.
Static water level
The undisturbed water level in a well measured before pumping begins, reflecting the natural piezometric head of the aquifer at that location.
Pumping water level
The stabilized water level in a well while it is being pumped at a constant rate, lower than static level because of drawdown around the borehole.
Drawdown
The difference between static water level and pumping water level in a well, expressed in feet or meters; it grows with pumping rate and aquifer resistance.
Specific capacity
Pumping rate divided by drawdown, usually in gallons per minute per foot; a higher value indicates a more productive well or aquifer.
Neat cement yield
One 94-pound sack of neat cement mixed with water yields about 1.15 cubic feet of grout, used to compute sacks needed for annular sealing.
Casing centralizer
A device attached to casing that keeps it centered in the borehole, promoting a uniform grout annulus and reducing the risk of voids or channeling.
Sieve analysis
A laboratory test that determines the particle size distribution of formation samples; results guide screen slot size and filter pack gradation selection.
Development
The process of removing drilling mud and fines from the borehole and filter pack so the well produces clear water at maximum efficient yield.
Artesian well
A well in which the confined aquifer's potentiometric surface stands above the ground surface, so water flows without pumping when the well is completed.
Grout placement
Pumping cement or bentonite slurry from the bottom of the annulus upward through a tremie pipe to seal the casing and protect groundwater from surface contamination.
Total dynamic head
The sum of pumping lift, discharge pressure head, and friction losses in pipe and fittings; it defines the duty point a pump must meet at design flow.
Pumping lift
The vertical distance from the pumping water level in the well to the discharge point, one component of total dynamic head for pump selection.
Brake horsepower formula
Pump brake horsepower equals gallons per minute times total dynamic head in feet, divided by 3960, then divided by pump efficiency.
Pump efficiency
The ratio of water horsepower delivered to the brake horsepower input at a given flow and head; it varies across the pump curve and peaks near best efficiency point.
Pump curve
A graph of pump head versus flow rate; the operating point is where the pump curve intersects the system head curve.
System head curve
A plot of required head versus flow for the piping system, rising with flow because friction losses increase approximately with the square of flow.
Best efficiency point
The flow rate at which a pump operates at its highest efficiency; operating far from it increases vibration, wear, and power consumption.
Submergence
The depth of a pump intake below the pumping water level; insufficient submergence causes vortexing, air entry, and loss of prime or motor cooling.
Check valve
A one-way valve installed above a submersible pump that holds the water column when the pump stops and prevents backspin of the impellers.
Drop pipe
The vertical pipe carrying water from a submersible pump to the surface; its diameter affects friction loss, and undersizing reduces delivered flow.
Pitless adapter
A fitting that passes water through the casing below the frost line, allowing the discharge line to connect without a pit and protecting the well from surface water.
Well seal
A watertight cap at the top of the casing that seals around the drop pipe, wiring, and vent, preventing contamination and supporting the pump assembly.
Voltage drop limit
The maximum permitted voltage loss in motor supply conductors, commonly 5 percent at the motor terminals; excessive drop causes overheating and reduced starting torque.
Three-phase rotation
The direction a three-phase motor turns; swapping any two supply leads reverses rotation, so rotation must be verified before the pump is run.
Amperage check
Comparison of measured motor current with nameplate full-load amps; current above rating suggests overload, low voltage, or a worn pump.