- Submersible pump stage
- One impeller and diffuser assembly in a submersible pump; adding stages increases total head at a given flow while raising required brake horsepower.
- Check valve function
- A one-way valve that holds the discharge water column when the pump stops, preventing backspin and backflow; a leak causes rapid cycling or loss of pressure.
- Bladder pressure tank
- A tank with a flexible bladder separating air precharge from water; it stores drawdown volume and maintains pressure between pump cut-in and cut-out settings.
- Pitless adapter
- A fitting that connects the well drop pipe to the building service line below frost depth and seals the casing, allowing the pump to be removed without excavation.
- Jet pump venturi
- A nozzle-and-venturi ejector that converts pressure energy into velocity to lift water; shallow systems use one pipe and deep systems use two pipes.
- Torque arrestor
- A rubber or mechanical device installed above a submersible pump to center the pump and limit motor twisting during startup, protecting the drop pipe and cable.
- Well seal
- A cap assembly that seals the top of the well casing around the drop pipe, wiring, and vent while supporting the pump piping and preventing surface contamination.
- Total dynamic head
- The sum of vertical lift, drawdown, discharge pressure head, and friction losses in feet; used to select a pump that meets design flow.
- Pressure head conversion
- One psi equals 2.31 feet of water head; multiply pressure in psi by 2.31 to convert to feet, or divide feet by 2.31 to obtain psi.
- Pump operating point
- The intersection of the pump performance curve and the system head curve; it defines the actual flow, head, and power draw at a given installation.
- Pressure tank drawdown
- The usable water volume expelled as tank pressure falls from cut-out to cut-in; it determines pump cycle volume and run time.
- Hydraulic horsepower formula
- Water horsepower equals flow in gallons per minute multiplied by total dynamic head in feet, divided by 3960; brake horsepower equals water horsepower divided by pump efficiency.
- Well yield
- The sustainable flow a well can produce without excessive drawdown; pump capacity should not exceed yield unless storage or controls limit pumping.
- Friction loss
- Pressure loss caused by water moving through pipe, fittings, and valves; it rises with flow and pipe roughness and must be added to system head.
- Two-wire submersible motor
- A submersible motor with starting components built into the motor housing; it connects directly to the pressure switch and requires no separate control box.
- Three-wire submersible motor
- A submersible motor that uses an external control box containing the capacitor and relay; three motor leads plus ground run from the well.
- Motor start capacitor
- A capacitor in a single-phase motor control box that provides starting torque; a failed capacitor can cause humming, tripped overloads, or failure to start.
- Pressure switch cut-out
- The upper pressure setting at which the switch opens and stops the pump; it must match tank precharge and system design pressure.
- Voltage drop limit
- Recommended maximum voltage drop is three percent on a branch circuit and five percent overall; excessive drop causes motor overheating and reduced starting torque.
- Insulation resistance test
- A test using a megohmmeter to measure motor and cable insulation resistance to ground; low readings indicate moisture damage or failing insulation.
- Pump setting depth
- Depth chosen so the pump intake stays below expected drawdown and above the well bottom, while allowing motor cooling flow and avoiding sediment.
- Pressure tank precharge
- Air pressure in a bladder tank with the water side drained; typically set two psi below cut-in pressure for a 20 psi pressure differential.
- Well disinfection
- Treatment of the well and piping with a chlorine solution after installation or repair, followed by flushing, to reduce bacterial contamination risk.
- Startup amp check
- Measurement of running current on each motor lead at design flow; current should match nameplate or pump curve and be balanced within acceptable limits.
- Constant-rate flow test
- A test that pumps at a fixed rate while recording water level and time to estimate sustainable yield and allowable drawdown for pump sizing.
- Submersible wire splice
- A waterproof, heat-shrink or resin-filled connection that restores insulation and strain relief on submersible cable; poor splices cause ground faults.
- Short cycling
- Rapid pump starts and stops caused by a waterlogged tank, leaking check valve, faulty pressure switch, or oversized pump relative to storage.
- Loss of prime
- A condition where a jet or suction pump has air in the suction line and cannot build pressure; causes include low water, leaks, or a failed foot valve.
- Lockout tagout
- An energy-control procedure that isolates electrical or mechanical power, applies a lock and tag, and verifies de-energization before service work.
- Backflow prevention
- Devices or air gaps that prevent contaminated water from reversing into a potable supply; required where cross-connections or chemical injection exist.
- Confined space entry
- Entry into a well pit or vault with limited egress and possible hazardous atmosphere; requires testing, ventilation, attendant, and rescue provisions before entry.
- Sanitary well cap
- A vermin-proof cap that seals the casing, vents the well, and excludes surface water and insects; a damaged cap allows contamination.