Well Pump Installer key terms
Well Pump Installer · Get comfortable with the vocabulary.
- Submersible Pump
- Related: Drop Pipe, Check Valve, Pump Setting Depth
A pump and motor assembly sealed in a watertight housing and installed below the water level inside a well. It pushes water up through a drop pipe to the surface.
- Jet Pump
- Related: Foot Valve, Pressure Tank
A surface-mounted pump that moves water by forcing part of the flow through a narrow nozzle, creating a vacuum that draws more water from the well. Shallow and deep well versions exist.
- Pressure Tank
- Related: Pressure Switch, Short Cycling
A sealed tank with a precharged air chamber that stores pressurized water. It limits pump starts and keeps water pressure steady between pump cycles.
- Pitless Adapter
- Related: Well Casing, Drop Pipe
A fitting attached to the well casing below the frost line that connects the drop pipe to the horizontal service line. It lets the pump be removed without digging up the line.
- Check Valve
- Related: Foot Valve, Submersible Pump
A one-way valve that lets water flow in only one direction. In a well system it stops water from draining back down and prevents the pump from spinning backward.
- Foot Valve
- Related: Jet Pump, Check Valve
A check valve installed at the bottom of a suction pipe on a jet pump system. It holds water in the pipe so the pump does not lose its prime.
- Torque Arrestor
- Related: Drop Pipe, Submersible Pump
A rubber or plastic device clamped around the drop pipe near the pump. It cushions motor starting torque and helps keep the pump centered inside the casing.
- Drop Pipe
- Related: Submersible Pump, Well Seal
The vertical pipe that carries water from the pump up to the wellhead. It also supports the weight of the pump and is made of steel, PVC, or polyethylene.
- Well Casing
- Related: Well Seal, Grout
The pipe lining the borehole that keeps the well open and blocks soil and surface water from entering. It is usually steel or PVC and must meet local construction rules.
- Well Seal
- Related: Well Casing, Drop Pipe
A cover and gasket assembly that closes the top of the well casing around the pipes and wires. It keeps contamination out and supports the drop pipe.
- Total Dynamic Head
- Related: Pump Curve, Friction Loss, Static Water Level
The total pressure energy a pump must supply, expressed in feet of water. It includes lift, system pressure, friction losses, and elevation differences in the discharge piping.
- Static Water Level
- Related: Pumping Water Level, Drawdown
The level of water in a well after the pump has been off long enough for the water to stabilize. It is measured from a fixed point at the wellhead.
- Pumping Water Level
- Related: Static Water Level, Drawdown
The water level in a well while the pump is running at a steady rate. It is lower than the static level because pumping creates drawdown around the well.
- Drawdown
- Related: Static Water Level, Pumping Water Level, Well Yield
The drop in water level in a well caused by pumping. It equals the static water level minus the pumping water level at a given flow rate.
- Flow Rate
- Related: Well Yield, Pump Curve
The volume of water delivered per unit of time, usually expressed in gallons per minute. It is matched to the well yield and the building's water demand.
- Pump Curve
- Related: Total Dynamic Head, Flow Rate
A manufacturer's graph showing how a pump's flow rate changes with total dynamic head, plus efficiency and power input. It is used to select a pump that meets the system demand.
- Well Yield
- Related: Drawdown, Flow Rate
The maximum rate at which a well can supply water sustainably, usually expressed in gallons per minute. It is found by a pump test or from driller records.
- Friction Loss
- Related: Total Dynamic Head, Flow Rate
The pressure lost as water moves through pipes, fittings, and valves because of resistance. It increases with flow rate and pipe length and must be included in head calculations.
- Pump Setting Depth
- Related: Drawdown, Submersible Pump
The depth at which the pump intake is placed in a well. It must be below the drawdown water level but high enough above the bottom to avoid sediment.
- Pressure Switch
- Related: Pressure Tank, Short Cycling
An electrical control that starts and stops the pump motor as system water pressure changes. Its cut-in and cut-out settings define the operating pressure range.
- Two-Wire Motor
- Related: Three-Wire Motor, Control Box
A submersible motor with starting components built into its housing that needs only two power leads plus a ground. It does not require a separate control box.
- Three-Wire Motor
- Related: Control Box, Capacitor
A submersible motor with three power leads plus a ground that requires a separate control box containing a starting capacitor and relay. It is common in larger horsepower sizes.
- Control Box
- Related: Three-Wire Motor, Capacitor
A surface-mounted enclosure that holds starting components such as capacitors and relays for a three-wire submersible motor. Two-wire motors do not use one.
- Capacitor
- Related: Control Box, Three-Wire Motor
An electrical part that stores and releases energy to help a motor start or run. A failed capacitor can stop the pump from starting or cause the motor to overheat.
- Megohmmeter
- Related: Submersible Cable
A test instrument that applies a high DC voltage to measure insulation resistance of motor windings and cable. Low readings point to moisture or damaged insulation.
- Ground Fault Circuit Interrupter (GFCI)
- Related: Lockout/Tagout
A protective device that shuts off power when it senses a small current leaking to ground. It lowers electric shock risk around water and is often required for pump circuits.
- Variable Frequency Drive
- Related: Pressure Switch, Short Cycling
An electronic controller that changes the frequency and voltage sent to a motor so pump speed can vary with demand. It can hold constant pressure and reduce cycling.
- Amp Draw
- Related: Pump Startup, Megohmmeter
The current a motor uses while running, measured with a clamp meter. Comparing it with the nameplate rating helps find overload, low voltage, or mechanical problems.
- Grout
- Related: Well Casing, Well Seal
A cement or bentonite mixture placed in the space between the well casing and the borehole wall. It seals the annulus and blocks surface water and shallow groundwater.
- Submersible Cable
- Related: Megohmmeter, Submersible Pump
Electrical cable made for underwater use that connects the motor to the surface power supply. It must be correctly sized, supported, and spliced to resist moisture.
- Chlorination
- Related: Well Casing, Well Seal
The process of adding chlorine to a well and water system to disinfect it after installation or repair. The solution is held for a contact time, then flushed out.
- Pump Startup
- Related: Amp Draw, Pressure Switch
The initial commissioning checks after installation, including voltage, motor rotation, amp draw, pressure settings, and flow. Proper startup confirms the system works within its design limits.
- Cavitation
- Related: Pump Running Dry, Total Dynamic Head
The forming and collapse of vapor bubbles in water when pressure drops below its vapor pressure, often at the pump intake. It causes noise, vibration, and impeller damage.
- Water Hammer
- Related: Check Valve, Pressure Tank
A pressure surge caused by a sudden change in water velocity, such as when a pump stops or a valve closes fast. It can damage pipes and fittings.
- Short Cycling
- Related: Pressure Tank, Pressure Switch
Rapid on-and-off operation of the pump, usually caused by a waterlogged pressure tank, wrong pressure switch settings, or a leaking check valve. It shortens motor life.
- Pump Running Dry
- Related: Dry-Run Protection, Pumping Water Level
Operation of a pump with little or no water at the intake, which can overheat the motor and damage seals and impellers. Dry-run protection shuts the pump off first.
- Dry-Run Protection
- Related: Pump Running Dry, Pressure Switch
A control feature that detects low flow, low pressure, or low current and stops the pump when water is unavailable. It prevents overheating and damage to pump and motor.
- Lockout/Tagout
- Related: Ground Fault Circuit Interrupter (GFCI), Pump Startup
A safety procedure that isolates electrical or mechanical energy and attaches a lock and warning tag. It prevents accidental startup while a pump or control is being serviced.
- Confined Space
- Related: Lockout/Tagout
A work area with limited entry or exit that is not meant for continuous occupancy, such as a well pit or vault. Entry requires air testing and a rescue plan.
- Backflow Prevention
- Related: Check Valve, Well Seal
Devices or practices that keep contaminated water from flowing backward into a well or public supply. An air gap or check valve may be required by plumbing codes.