Compressor Trips on High Discharge Temperature in Summer

ROC-M Exam ยท Put your knowledge to work in context.

All case studies

Compressor Trips on High Discharge Temperature in Summer

A rotary screw air compressor rated 22 m3/min at 800 kPa runs in a plant room that reaches 41 C in summer. It trips on high discharge temperature at 105 C, which is the shutdown setpoint. Normal running discharge temperature is 88 C in winter. The oil cooler is a fin-and-tube unit with a fan; the fins show dust loading on the inlet side. Oil level is at the minimum mark. The oil filter differential is 1.8 bar against a 2.0 bar changeout limit. Ambient air for the compressor is drawn from the plant room, which also houses two other compressors. The machine ran 6,000 hours since last oil change, with a 4,000-hour recommended interval.

1. Rank the likely causes of the high discharge temperature and justify the ranking.

Read the worked answer

Ranking by likely contribution and ease of correction:

  1. Fouled oil cooler. Dust on the fins reduces heat rejection directly. This is the most common cause of a summer-only trip, and the inlet-side loading confirms it. Cleaning is low cost and high impact.
  2. High ambient intake temperature. The compressor draws 41 C room air, and two other machines add heat. Inlet air temperature directly raises the compression temperature rise. Winter running at 88 C versus summer tripping is consistent with this.
  3. Oil level at minimum. Less oil means less heat removal from the airend and higher oil temperature. Topping up is simple.
  4. Oil change overdue at 6,000 hours against 4,000. Degraded oil loses heat transfer and lubricity.
  5. Oil filter differential at 1.8 bar, near the 2.0 bar limit. Restricted flow reduces oil to the airend and cooler performance.

Less likely but possible: a failing thermostatic control valve stuck in the wrong position, or a worn airend. These should be checked after the simple items are corrected.

2. Propose a corrective plan and a monitoring method to prevent recurrence.

Read the worked answer

Corrective plan:

  1. Clean the oil cooler fins and check fan operation and airflow path. Consider relocating or ducting cooler intake air from outside or from a cooler zone.
  2. Top up oil to the correct level and change oil and oil filter now, given the 6,000-hour run and near-limit differential.
  3. Improve plant room ventilation. Add exhaust or intake fans sized for the total heat load of all three compressors. Target room temperature below 35 C.
  4. Check the thermostatic oil control valve and the discharge temperature sensor calibration.
  5. Review the 4,000-hour oil interval against actual oil analysis results and set a condition-based schedule.

Monitoring: log discharge temperature, oil level, filter differential, and room temperature weekly. Set an alarm at 98 C so action is taken before the 105 C trip. Trend oil analysis at each change to catch degradation early. Record ambient temperature alongside discharge temperature so summer trends are visible before the trip point is reached.