ROC-M Exam key terms
ROC-M Exam ยท Get comfortable with the vocabulary.
- Pressure relief valve
- Related: Set pressure, Accumulation, Hydrostatic test
A spring-loaded device that opens automatically at a set pressure to discharge fluid and protect a boiler, vessel, or piping system from overpressure, then closes again as pressure falls.
- Set pressure
- Related: Pressure relief valve, Maximum allowable working pressure, Accumulation
The inlet pressure at which a relief device is adjusted to begin opening under operating conditions. It is stamped on the device and must not exceed the vessel's maximum allowable working pressure.
- Maximum allowable working pressure
- Related: Set pressure, Hydrostatic test, Accumulation
The highest internal pressure permitted in a boiler or pressure vessel at a stated temperature, based on design thickness, material strength, and code rules. It establishes the ceiling for relief device settings.
- Accumulation
- Related: Pressure relief valve, Set pressure
The pressure increase above the maximum allowable working pressure that occurs while a relief device is discharging at its rated capacity. Codes limit this rise, commonly to ten percent for boilers.
- Hydrostatic test
- Related: Maximum allowable working pressure, Pressure relief valve, Non-destructive examination
A strength and leak test in which a vessel or piping system is filled with water and pressurized above its design pressure, then inspected for distortion, leakage, and permanent deformation before being returned to service.
- Low-water cutoff
- Related: Safety valve, Combustion air, Steam trap
A safety control on a boiler that senses water level and shuts off the burner when the level drops below a safe limit, preventing overheating and catastrophic failure of the pressure vessel.
- Combustion air
- Related: Low-water cutoff, Flame safeguard
The air supplied to a burner to mix with fuel and support complete burning. Insufficient supply causes carbon monoxide, soot, and flame instability, and it is verified during startup and annual servicing.
- Steam trap
- Related: Water hammer, Low-water cutoff
A device that automatically discharges condensate and non-condensable gases from steam lines while retaining live steam, maintaining heat transfer efficiency and preventing water hammer in the distribution system.
- Water hammer
- Related: Steam trap, Check valve, Surge
A pressure surge caused by the sudden stopping or reversal of fluid flow, producing a loud banging noise and potentially damaging pipes, fittings, and supports. It is prevented by proper trapping, venting, and slow valve operation.
- Check valve
- Related: Water hammer, Cavitation
A valve that permits flow in one direction only and closes automatically when flow reverses, protecting pumps, compressors, and piping from backflow, reverse rotation, and hydraulic shock.
- Gate valve
- Related: Globe valve, Check valve
A valve with a sliding wedge or disc that moves perpendicular to the flow path, giving low resistance when fully open. It is intended for isolation service, not throttling, because partial opening erodes the seat.
- Globe valve
- Related: Gate valve, Control valve
A valve with a plug and seat arranged so flow changes direction, producing higher resistance but fine throttling control. It is commonly used for regulating flow and for frequent open-close duty.
- Control valve
- Related: Globe valve, PID controller, Actuator
A modulating valve positioned by an actuator in response to a controller signal to regulate flow, pressure, temperature, or level. Correct sizing and fail-safe action are essential to loop stability.
- Cavitation
- Related: Net positive suction head, Check valve, Vibration analysis
The formation and collapse of vapor bubbles in a pump or valve where local pressure falls below vapor pressure. Collapse produces noise, vibration, and metal erosion, reducing capacity and damaging impellers.
- Net positive suction head
- Related: Cavitation, Centrifugal pump
The absolute pressure margin above vapor pressure available at a pump suction, expressed in head. Insufficient margin causes cavitation, so the available value must exceed the required value given by the manufacturer.
- Centrifugal pump
- Related: Net positive suction head, Cavitation, Affinity laws
A rotodynamic machine that adds energy to liquid by spinning it outward through an impeller, converting velocity into pressure. Its flow varies with system resistance and it must never run deadheaded.
- Affinity laws
- Related: Centrifugal pump, Variable frequency drive
Relationships showing how pump or fan flow, head, and power change with speed or impeller diameter. Flow varies with speed, head with speed squared, and power with speed cubed, guiding speed control savings.
- Mechanical seal
- Related: Centrifugal pump, Vibration analysis
A pair of lapped faces, one rotating and one stationary, held together by spring pressure and fluid film to prevent leakage along a rotating shaft. It requires clean flush fluid and correct installation.
- Vibration analysis
- Related: Mechanical seal, Condition monitoring, Cavitation
A predictive maintenance technique that measures machine vibration and interprets frequency spectra to detect imbalance, misalignment, bearing defects, and looseness before functional failure occurs.
- Condition monitoring
- Related: Vibration analysis, Preventive maintenance
Periodic or continuous measurement of machine parameters such as vibration, temperature, oil debris, and pressure to track health and schedule maintenance based on actual need rather than elapsed time.
- Preventive maintenance
- Related: Condition monitoring, Vibration analysis
Scheduled servicing, lubrication, adjustment, and replacement performed at fixed intervals to reduce unexpected failures. It is time-based, unlike predictive work driven by measured condition.
- Non-destructive examination
- Related: Hydrostatic test, Weld procedure specification
Inspection methods such as radiography, ultrasonic testing, magnetic particle, dye penetrant, and visual inspection that reveal defects in welds and materials without damaging the component under test.
- Weld procedure specification
- Related: Non-destructive examination, Hydrostatic test
A written document that specifies the materials, joint design, preheat, filler, current, and technique qualified by testing for a particular weld. Welders must follow it to ensure code compliance.
- Lockout/tagout
- Related: Permit to work, Confined space entry
A safety procedure that isolates hazardous energy sources, applies locks and tags, and verifies zero energy before maintenance, preventing unexpected startup or release of stored energy such as steam or pressure.
- Confined space entry
- Related: Lockout/tagout, Permit to work
Entry into a space with limited access and poor ventilation that is not designed for occupancy, requiring atmospheric testing, ventilation, an attendant, and a written permit before personnel may enter.
- Permit to work
- Related: Lockout/tagout, Confined space entry
A formal written authorization describing the task, hazards, controls, and required isolations, signed before high-risk work such as hot work, confined space entry, or line breaking begins.
- Flame safeguard
- Related: Combustion air, Low-water cutoff
A control system that proves main flame or pilot establishment and supervises it continuously, shutting off fuel within a safe time if flame is lost, preventing furnace explosions from unburned fuel.
- PID controller
- Related: Control valve, Actuator
A controller that combines proportional, integral, and derivative actions to reduce error between a measured variable and setpoint. Tuning balances speed of response against stability and overshoot.
- Actuator
- Related: Control valve, PID controller
A device, powered electrically, pneumatically, or hydraulically, that moves a valve or damper to a commanded position. Its fail-safe mode determines equipment behavior on loss of power or signal.
- Variable frequency drive
- Related: Affinity laws, Motor overload protection
An electronic device that varies the speed of an alternating-current motor by adjusting supply frequency and voltage, enabling flow control by speed change instead of throttling and reducing energy use.
- Motor overload protection
- Related: Variable frequency drive, Lockout/tagout
A protective device that disconnects a motor when sustained current exceeds its rating, preventing winding overheating from overload, single phasing, or mechanical binding while allowing normal starting current.
- Chiller
- Related: Refrigerant, Superheat, Compressor
A refrigeration machine that removes heat from a liquid, usually water, for air conditioning or process cooling. It comprises a compressor, evaporator, condenser, and expansion device in a vapor-compression cycle.
- Superheat
- Related: Subcooling, Thermostatic expansion valve, Chiller
The temperature of refrigerant vapor above its saturation temperature at a given pressure. Measured at the evaporator outlet, it confirms the expansion valve setting and protects the compressor from liquid slugging.
- Subcooling
- Related: Superheat, Chiller
The amount by which liquid refrigerant is cooled below its saturation temperature at a given pressure. Measured at the condenser outlet, it indicates charge level and condenser performance.
- Thermostatic expansion valve
- Related: Superheat, Chiller
A metering device that regulates refrigerant flow into an evaporator by sensing suction superheat at the outlet, maintaining superheat within a range and matching flow to load.
- Refrigerant
- Related: Chiller, Superheat
A fluid used in a refrigeration cycle that absorbs heat by evaporating at low pressure and releases it by condensing at high pressure. Selection considers safety group, ozone depletion, and global warming potential.
- Compressor
- Related: Surge, Chiller
A machine that raises gas pressure by reducing volume. Types include reciprocating, rotary screw, and centrifugal; surge, overheating, and lubricant condition are key operating concerns.
- Surge
- Related: Compressor, Check valve, Water hammer
An unstable operating condition in a centrifugal compressor or fan where flow reverses momentarily, causing violent pressure pulsations, noise, and possible mechanical damage. It is avoided by staying above minimum flow.
- Air handling unit
- Related: Chiller, Actuator
An assembly containing a fan, coils, filters, dampers, and controls that conditions and moves air through ducts to served spaces. Balancing and filter maintenance strongly affect its delivered capacity.