OAA Admission Exam flashcards
OAA Admission Exam · Build recall with a focused review session.
34 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Standard of Care
- The degree of skill and care ordinarily exercised by architects under similar circumstances in the same locality. It is a benchmark of reasonable practice, not a guarantee of perfect results.
- Claims-Made Insurance
- Professional liability coverage that responds to claims reported during the active policy period, regardless of when the underlying error occurred, subject to a retroactive date.
- Statute of Repose
- A law setting an absolute deadline for filing construction claims measured from substantial completion, regardless of when the defect is discovered. It limits long-tail liability.
- Architect's Lien
- A statutory claim against real property securing payment for architectural services. Filing requirements, notice periods, and eligibility vary by jurisdiction and must be strictly followed.
- Instruments of Service
- Drawings, specifications, and other documents the architect prepares. The architect typically retains copyright and grants the client a license limited to the specific project.
- Percentage Fee
- A compensation method where the architect's fee equals an agreed percentage of the construction cost. It scales with project size but can discourage cost control.
- Conflict of Interest
- A situation where the architect has a personal or financial interest that could bias professional judgment. It requires written disclosure and, often, client consent.
- Seal and Signature
- The architect's stamp certifying that documents were prepared by or under the direct supervision of a licensed architect. Misuse constitutes unauthorized practice and grounds for discipline.
- Thermal Resistance R
- A measure of a material's resistance to heat flow, equal to thickness divided by thermal conductivity. Assembly R-values sum the layers plus surface film resistances.
- U-Value
- The overall rate of heat transfer through an assembly, equal to one divided by the total R-value. Lower U-values indicate better insulating performance.
- Heat Loss Formula
- Q equals U times area times temperature difference. This steady-state equation estimates conduction heat loss through an assembly given its U-value and the indoor-outdoor temperature gap.
- Dead versus Live Load
- Dead load is the static weight of structure and permanent finishes. Live load is transient occupancy, furniture, and equipment, taken from code tables for design.
- Concrete Compressive Strength
- Denoted f'c, measured at 28 days, typically 3,000 to 5,000 psi. Steel reinforcement is added because concrete is strong in compression but weak in tension.
- Sensible Heat Equation
- Q equals 1.08 times CFM times the temperature difference in Fahrenheit. It estimates the sensible cooling or heating load carried by an air stream.
- Fire-Resistance Rating
- The time in hours an assembly resists fire exposure, determined by standardized furnace testing such as ASTM E119. Ratings appear as one, two, three, or four hours.
- Beam Deflection Limit
- A serviceability criterion limiting how far a beam may sag, often span divided by 360 for floors. Stricter limits apply where brittle finishes or glass are supported.
- Daylight Factor
- Interior illuminance divided by exterior horizontal illuminance, expressed as a percentage. Values around two percent or higher are generally desirable for occupied spaces.
- Occupancy Groups
- Code classifications by use, such as assembly, business, educational, factory, high hazard, institutional, mercantile, residential, storage, and utility. They drive egress and fire requirements.
- Construction Types I to V
- Five code categories ranked by fire resistance. Type I is noncombustible with the highest rating; Type V is wood frame with the least restrictive requirements.
- Occupant Load
- The computed number of people a space is designed to hold, found by dividing floor area by the code occupant load factor for that use.
- Means of Egress Components
- The continuous path from any point to safety, comprising exit access, the exit itself, and exit discharge. Each component has separate width, travel, and protection rules.
- Egress Width Capacity
- Required stair and corridor width computed by multiplying occupant load by a code factor, such as 0.2 inches per occupant for stairs in many model codes.
- Floor Area Ratio
- Gross floor area of a building divided by its lot area. Zoning ordinances use FAR to cap building bulk independently of height limits and setbacks.
- Accessible Route
- A continuous unobstructed path connecting accessible spaces and elements. It typically requires a 36-inch clear width, with 32 inches minimum at doorways.
- Fire Separation Distance
- The distance from a building face to the lot line or to another building on the same lot. It determines required exterior wall rating and opening protection.
- Allowable Area Increase
- Permitted increases to base tabular floor area for frontage on open space and for sprinkler protection. Height and story limits are adjusted separately.
- Design-Bid-Build
- A linear delivery method where the owner contracts separately with the architect for design and the contractor for construction after competitive bidding. It offers low initial cost but limited coordination.
- Change Order
- A written modification to the contract scope, price, or time, signed by owner, architect, and contractor. It is the formal mechanism for adjusting the agreement.
- Construction Change Directive
- A written order directing the contractor to proceed with a change before price and time are agreed. It is later converted to a change order.
- Request for Information
- A formal query from the contractor seeking clarification of the contract documents. Responses that alter scope or cost should be processed as a change order.
- Submittal Review
- The architect's check of shop drawings and samples for design intent and contract compliance. Review does not verify dimensions or approve construction means and methods.
- Substantial Completion
- The stage when work is sufficiently complete for its intended use, triggering warranty periods, retainage release, and preparation of the punch list.
- Liquidated Damages
- A pre-agreed per-day sum the contractor owes for late completion. Courts enforce it only when it reasonably forecasts actual damages rather than serving as a penalty.
- Critical Path and Float
- The critical path is the longest chain of dependent activities and sets project duration. Float is the slack available on non-critical activities without delaying completion.