OBC Detection, Lighting & Power key terms
OBC Detection, Lighting & Power · Get comfortable with the vocabulary.
- Coverage zone
- Related: Field of view, Detection threshold
The physical area or volume that a detection sensor is intended to monitor. Its size and shape depend on sensor technology, mounting height, and any obstructions present.
- Field of view
- Related: Coverage zone, Blind spot
The angular spread over which a sensor can receive signals or radiation. It is usually stated in degrees horizontally and vertically and determines how much area one device can watch.
- Blind spot
- Related: Coverage zone, Field of view
A region inside the intended monitored area that a sensor cannot see, often caused by structural obstructions, ductwork, or mounting geometry. Blind spots must be identified and compensated for during design.
- Detection threshold
- Related: Nuisance alarm, Sensitivity setting
The minimum signal level or change a sensor must receive before it registers an alarm condition. Setting it too low invites nuisance alarms; setting it too high risks missed events.
- Nuisance alarm
- Related: Detection threshold, Sensitivity setting
A false activation triggered by environmental conditions, air movement, or interference rather than a genuine event. Reducing nuisance alarms usually involves adjusting sensitivity, placement, or filtering.
- Sensitivity setting
- Related: Detection threshold, Nuisance alarm
An adjustable control that determines how readily a sensor responds to input. Higher sensitivity improves detection of small events but increases the chance of false alarms from background noise.
- Point detection
- Related: Coverage zone, Beam detection
A sensing approach that monitors a single location rather than an area. A spot-type device reacts only when the condition reaches that specific point, so placement is critical.
- Beam detection
- Related: Point detection, Field of view
A sensing method that projects a signal along a line between a transmitter and receiver. Interruption of the path produces an alarm, making it suitable for long corridors or perimeter runs.
- Luminaire
- Related: Ballast, Luminaire disconnect
A complete lighting unit consisting of the lamp or light source, housing, reflector, lens, and any integral control gear. It is the assembly installed on a circuit, not just the lamp.
- Ballast
- Related: Luminaire, Driver
A device that regulates current through a discharge lamp and provides the voltage needed to start it. Electronic types may also correct power factor and reduce flicker.
- Driver
- Related: Ballast, Luminaire
Power-conditioning equipment that converts supply voltage into the regulated current required by an LED module. It may be integral to the luminaire or mounted remotely.
- Luminaire disconnect
- Related: Lockout/tagout, Luminaire
A switching device located at or within a luminaire that opens the supply conductors for servicing. It allows safe maintenance without de-energizing the entire branch circuit.
- Switch leg
- Related: Three-way switching, Neutral conductor
The conductor that carries switched power from a switch to the controlled load. It is typically re-identified at its terminations so it is not confused with an unswitched hot.
- Three-way switching
- Related: Switch leg, Traveler conductor
A control arrangement using two three-way switches to operate one load from two locations. Traveler conductors link the switches, and the load is fed from the common terminal of one switch.
- Traveler conductor
- Related: Three-way switching, Switch leg
One of the conductors that connects the traveler terminals of two three-way or four-way switches. It may be energized depending on switch position, so it must be treated as live during testing.
- Branch circuit
- Related: Overcurrent protection, Feeder
The circuit conductors between the final overcurrent device and the outlets or loads it serves. Lighting and small appliance loads are commonly supplied by dedicated branch circuits.
- Feeder
- Related: Branch circuit, Panelboard
The circuit conductors between the service equipment or source and the final branch-circuit overcurrent devices. Feeders carry the combined load of the panelboard they supply.
- Overcurrent protection
- Related: Branch circuit, Coordination
A device or system that interrupts current when it exceeds a safe value, protecting conductors and equipment from overheating. Fuses and circuit breakers are common examples.
- Coordination
- Related: Overcurrent protection, Selective tripping
The intentional selection of overcurrent devices so that the device nearest a fault opens first. Proper coordination limits outage scope and prevents upstream devices from tripping unnecessarily.
- Selective tripping
- Related: Coordination, Overcurrent protection
The result of correct coordination, in which only the protective device closest to a fault operates. It keeps the rest of the distribution system energized during a local fault.
- Panelboard
- Related: Feeder, Circuit directory
An enclosure containing buses and overcurrent devices that distributes power to branch circuits or feeders. It is the central point for circuit identification and load balancing.
- Circuit directory
- Related: Panelboard, Lockout/tagout
The written schedule, mounted at a panelboard, that identifies what each circuit and overcurrent device serves. It must be accurate and updated whenever circuits are changed.
- Ampacity
- Related: Voltage drop, Conductor sizing
The maximum current a conductor can carry continuously under stated conditions without exceeding its temperature rating. It depends on conductor size, insulation, and installation environment.
- Voltage drop
- Related: Ampacity, Conductor sizing
The reduction in voltage along a circuit caused by conductor resistance and current flow. Excessive drop causes dimming, poor equipment performance, and wasted energy.
- Conductor sizing
- Related: Ampacity, Voltage drop
Selecting a conductor gauge large enough to carry the load current safely while keeping voltage drop within acceptable limits. It considers ampacity, ambient temperature, and run length.
- Neutral conductor
- Related: Switch leg, Grounding electrode conductor
The grounded circuit conductor that carries return current in a normally balanced system. It must be sized appropriately and never switched or fused as though it were a hot conductor.
- Termination
- Related: Torque specification, Wire connector
The point at which a conductor is mechanically and electrically joined to a device, lug, or bus. Correct torque and surface preparation are essential to a reliable, low-resistance connection.
- Torque specification
- Related: Termination, Thermal scan
The manufacturer-stated tightening value for a terminal or lug. Under-tightening causes overheating; over-tightening can damage threads or conductors, so a calibrated tool is used.
- Wire connector
- Related: Termination, Conductor sizing
A device that joins two or more conductors securely while insulating the joint. The correct type and size must match the conductor material, gauge, and environment.
- Grounding electrode conductor
- Related: Bonding jumper, Equipment grounding conductor
The conductor that connects the system grounded point to the grounding electrode. It provides a low-impedance path intended to carry fault and surge current to earth.
- Equipment grounding conductor
- Related: Ground fault, Bonding jumper
The conductor that connects non-current-carrying metal parts of equipment to the grounding system. It provides the fault-return path that lets overcurrent devices clear a ground fault.
- Bonding jumper
- Related: Equipment grounding conductor, Grounding electrode conductor
A conductor that ensures electrical continuity between metal parts that must be at the same potential. It is not intended to carry normal load current.
- Ground fault
- Related: Equipment grounding conductor, Residual current device
An unintentional current path from an energized conductor to ground or to grounded metal. It can create shock hazard and must be cleared quickly by protective devices.
- Residual current device
- Related: Ground fault, Lockout/tagout
A protective device that trips when it detects a small imbalance between outgoing and returning current, indicating leakage to ground. It protects people rather than conductors.
- Lockout/tagout
- Related: Luminaire disconnect, Circuit directory
A safety procedure in which an energy source is isolated, locked, and tagged before work begins. It prevents accidental re-energization and is mandatory before servicing circuits.
- Thermal scan
- Related: Torque specification, Termination
An infrared inspection technique that reveals hot spots at terminals, breakers, and connections under load. Temperature differences indicate loose joints or overloaded components before failure occurs.
- Continuity test
- Related: Insulation resistance test, Equipment grounding conductor
A check confirming that a low-resistance path exists between two points, typically performed with the circuit de-energized. It verifies conductors, switches, and bonding connections.
- Insulation resistance test
- Related: Continuity test, Megohmmeter
A measurement of the resistance of insulation between conductors or to ground, made with a high-voltage tester. Low readings indicate moisture, damage, or deterioration.
- Megohmmeter
- Related: Insulation resistance test
An instrument that applies a high test voltage to measure insulation resistance. Readings are compared against manufacturer limits or prior baseline values to judge condition.