- Secondary containment
- Related: Spill bucket, Interstitial space, Leak detection
A liquid-tight barrier, such as a double-wall tank or dike, that holds the contents of the primary tank if it leaks, preventing fuel from reaching soil or groundwater.
- Interstitial space
- Related: Secondary containment, Leak detection, Tank tightness test
The gap between the inner and outer walls of a double-wall tank or piping. Monitoring this space reveals leaks from either wall before product escapes to the environment.
- Spill bucket
- Related: Fill connection, Secondary containment
A small reservoir around the fill connection that catches product displaced or spilled during delivery, keeping it out of the containment sump and environment.
- Overfill prevention valve
- Related: Fill connection, Spill bucket, Stage II vapor recovery
A device in the tank fill line that restricts or stops flow when the tank reaches a set level, reducing the risk of overfilling during a delivery.
- Stage II vapor recovery
- Related: Vapor balance system, Overfill prevention valve
Equipment that captures gasoline vapors displaced from a vehicle tank during refueling and returns them to the storage tank instead of releasing them to the air.
- Vapor balance system
- Related: Stage II vapor recovery, Dispenser
A Stage II arrangement in which displaced vehicle-tank vapor flows through a coaxial hose and nozzle back into the storage tank as liquid fuel flows out.
- Dispenser
- Related: Shear valve, Breakaway coupling, Meter calibration
The assembly that meters fuel and delivers it to a vehicle, including the pump, meter, hose, nozzle, and safety controls such as breakaway and shear valves.
- Shear valve
- Related: Dispenser, Breakaway coupling, Emergency shutoff
A valve at the base of a dispenser that closes automatically if the dispenser is struck or displaced, stopping the flow of product from the supply piping.
- Breakaway coupling
- Related: Dispenser, Shear valve
A fitting in the dispenser hose that separates at a designed force to release the hose without tearing, then seals both ends to limit product release.
- Meter calibration
- Related: Dispenser, Prover test
The process of adjusting and verifying a dispenser's meter so the volume shown matches the volume delivered within the tolerance allowed by weights and measures rules.
- Emergency shutoff
- Related: Shear valve, Emergency stop button
A clearly marked device, usually at the dispenser or a remote station, that immediately stops fuel flow and power to dispensing equipment in an emergency.
- Emergency stop button
- Related: Emergency shutoff, Motor control center
A manually operated switch, typically red and mushroom-shaped, that removes power from dispensing equipment when pressed and must be manually reset.
- Motor control center
- Related: Emergency stop button, Hazardous location
A cabinet or assembly containing motor starters, breakers, and controls for equipment such as submersible pumps, organized into sections and fed from a main disconnect.
- Hazardous location
- Related: Intrinsically safe, Explosion-proof enclosure, Area classification
An area where flammable vapors, gases, or dusts may be present in quantities that require specially rated electrical equipment to prevent ignition.
- Area classification
- Related: Hazardous location, Explosion-proof enclosure
The process of dividing a facility into zones or divisions by the likelihood and duration of flammable vapor presence, which determines the electrical equipment permitted there.
- Intrinsically safe
- Related: Hazardous location, Area classification
A circuit design in which energy is limited so that sparks or heat cannot ignite a flammable atmosphere, allowing safe use in hazardous locations.
- Explosion-proof enclosure
- Related: Hazardous location, Area classification
A housing built to contain an internal explosion and prevent ignition of surrounding flammable vapor, with joints designed to cool escaping gases.
- Leak detection
- Related: Interstitial space, Tank tightness test, Secondary containment
A system of sensors, monitoring wells, or interstitial monitoring that identifies product loss from tanks or piping and triggers alarms or shutdowns.
- Tank tightness test
- Related: Leak detection, Interstitial space
A test that pressurizes or measures liquid level in a tank and piping to confirm they hold product without measurable loss over a defined period.
- Prover test
- Related: Meter calibration, Dispenser
A field test using a calibrated measuring container to compare the volume a dispenser meter registers with the true volume delivered.
- Cathodic protection
- Related: Impressed current system, Sacrificial anode
A method that applies a small electrical current or sacrificial anodes to buried steel tanks and piping to prevent corrosion by making the metal the cathode.
- Sacrificial anode
- Related: Cathodic protection, Impressed current system
A metal, usually magnesium or zinc, installed to corrode preferentially and protect buried steel tank or piping from corrosion.
- Impressed current system
- Related: Cathodic protection, Sacrificial anode
A cathodic protection system that uses an external power source and inert anodes to supply protective current to buried metal structures.
- Fire code occupancy classification
- Related: Fire separation, Means of egress
The category assigned to a building based on its use and hazard, which sets requirements for construction, egress, and fire protection systems.
- Fire separation
- Related: Fire code occupancy classification, Fire-resistance rating
A rated wall, floor, or assembly that resists fire spread for a stated time, separating hazardous areas from occupied spaces or adjoining buildings.
- Fire-resistance rating
- Related: Fire separation, Means of egress
The time in hours that a building assembly maintains its structural integrity and limits heat transfer when tested under a standard fire exposure.
- Means of egress
- Related: Fire separation, Fire-resistance rating
The continuous path from any point in a building to a public way, including exit access, the exit itself, and exit discharge.
- Structural load path
- Related: Dead load, Live load
The route by which gravity, wind, and seismic forces travel through a structure's members down to the foundation.
- Dead load
- Related: Live load, Structural load path
The permanent weight of a structure's own materials and fixed equipment, which the structural system must support throughout its life.
- Live load
- Related: Dead load, Structural load path
The variable weight imposed by occupants, vehicles, stored goods, and movable equipment that a structure must be designed to carry.
- Canopy
- Related: Dispenser, Structural load path
A roof structure over dispensing islands that shelters customers and equipment, and must be designed for wind uplift and drainage.
- Concrete containment dike
- Related: Secondary containment, Spill bucket
A raised curb or wall around tank or dispensing areas that holds spilled fuel within a bounded area for recovery and cleanup.
- Stormwater separator
- Related: Concrete containment dike, Spill prevention plan
A device that removes oil and sediment from runoff before it leaves a site, protecting drainage systems and waterways from fuel contamination.
- Spill prevention plan
- Related: Stormwater separator, Leak detection
A written site document describing fuel storage, potential release scenarios, and the equipment and procedures used to prevent and respond to spills.
- Hot work permit
- Related: Fire watch, Lockout/tagout
A written authorization required before welding, cutting, or other spark-producing work near fuel systems, confirming precautions and fire watch are in place.
- Fire watch
- Related: Hot work permit
A person assigned to monitor an area for fire during and after hot work, with the authority and equipment to extinguish or report a fire immediately.
- Lockout/tagout
- Related: Hot work permit, Motor control center
A safety procedure that isolates energy sources and applies locks and tags so equipment cannot be started while maintenance or construction work proceeds.
- As-built drawing
- Related: Punch list, Hydrostatic test
A drawing updated to show the actual installed conditions of a completed project, used for future maintenance, inspection, and modifications.
- Punch list
- Related: As-built drawing, Hydrostatic test
A record of outstanding defects or incomplete work identified near project completion that must be corrected before final acceptance.
- Hydrostatic test
- Related: Tank tightness test, Punch list
A pressure test that fills piping or a tank with water to a specified pressure and checks for leaks and pressure loss before the system is placed in service.