Quick reference

Water Sources, Quality, and Regulations

  • Safe Drinking Water Act (SDWA) authorizes EPA to set national standards; states like California may adopt stricter rules under primacy, and California's SWRCB Division of Drinking Water enforces them through Title 22 CCR.

  • Primary MCLs address health effects (e.g., nitrate as N 10 mg/L, arsenic 0.010 mg/L, lead action level 0.015 mg/L, total coliform treatment technique); secondary standards (250 mg/L chloride, 500 mg/L TDS, 0.3 NTU turbidity) address aesthetics and are non-enforceable federally.

  • Surface Water Treatment Rule requires filtered systems to achieve 0.3 NTU in 95% of monthly samples and never exceed 1 NTU, plus combined removal/inactivation of 3-log Giardia and 4-log virus.

  • Groundwater under the direct influence of surface water (GWUDI) must be determined by site-specific inspection or microscopic particulate analysis; GWUDI sources are regulated as surface water.

  • Total coliform Rule: a routine positive sample triggers repeat sampling within 24 hours; MCL violation occurs when repeat samples confirm total coliform with E. coli present or when repeat sampling is not performed.

  • Nitrate is the acute risk parameter for infants (methemoglobinemia); sample quarterly or annually depending on source type, and confirm any result above 5 mg/L with a second sample.

  • Disinfection Byproduct Rule limits: TTHM 80 ug/L and HAA5 60 ug/L as locational running annual averages at each monitoring location.

  • Source water assessment and wellhead protection: California requires sanitary surveys every 5 years for surface water and every 5 years for groundwater systems, documenting source vulnerabilities and required corrections.

Quick reference

Coagulation, Flocculation, and Sedimentation

  • Jar test procedure: rapid mix 1-2 minutes at 200-300 rpm, flocculate 15-20 minutes at 20-40 rpm in decreasing steps, settle 15-30 minutes, then measure turbidity and pH of supernatant.

  • Optimum coagulant dose is identified by the lowest settled turbidity, not by the lowest raw turbidity or shortest floc formation time; confirm with filtered turbidity where possible.

  • Alum (Al2(SO4)3·14H2O) consumes 0.45-0.50 mg/L alkalinity as CaCO3 per mg/L dose and depresses pH; ferric chloride consumes about 0.54 mg/L alkalinity per mg/L dose.

  • Coagulation pH windows: alum performs best near pH 6.0-7.5, ferric salts near pH 4-9 with optimum 5.5-6.5; outside these windows solubility increases and residual metal rises.

  • Zeta potential near zero indicates charge neutralization; typical target range is -5 to +5 mV, while sweep-floc operation tolerates more negative values because enmeshment dominates.

  • Sedimentation design: surface overflow rate = flow / surface area (m3/d per m2); typical values 20-40 m3/d·m2 for alum flocs and 40-60 m3/d·m2 with tube settlers or plate settlers.

  • Detention time = volume / flow; typical flocculation basins provide 15-30 minutes and sedimentation basins 2-4 hours.

  • Weir loading rate = flow / total weir length; keep below about 250 m3/d per m of weir to avoid floc shearing and short-circuiting.

Quick reference

Filtration

  • Rapid sand filter media: effective size 0.45-0.55 mm, uniformity coefficient 1.3-1.5, bed depth 24-30 inches; anthracite dual media uses 0.9-1.1 mm effective size above sand.

  • Filter loading rate = flow / filter area; typical 4-8 m/h (about 2-4 gpm/ft2) for rapid gravity filters; exceeding design rate degrades effluent turbidity.

  • Backwash: 15-20 gpm/ft2 (35-50 m/h) with 20-30% bed expansion for 8-15 minutes; air scour at 3-5 scfm/ft2 improves cleaning in dual media.

  • Filter-to-waste for 15-30 minutes after backwash prevents a turbidity spike from entering the clearwell; this is a required practice in many states.

  • Terminal headloss triggers backwash typically at 6-10 ft (2-3 m) of water column; filter run times of 24-72 hours are typical.

  • Individual filter effluent must stay below 1.0 NTU; if it exceeds 1.0 NTU for two consecutive 15-minute readings, the filter is considered to have a significant deficiency requiring reporting.

  • Slow sand filters operate at 0.1-0.4 m/h with schmutzdecke development over 1-3 weeks; cleaning is by scraping 1-2 cm of the surface layer.

  • Media loss, mudballs, and air binding are common filter problems; air binding is corrected by improving backwash or increasing filter head.

Quick reference

Disinfection and Disinfection Byproducts

  • CT = disinfectant residual concentration (mg/L) × contact time (minutes); required CT depends on disinfectant, pH, temperature, and target log inactivation.

  • Chlorine demand = applied dose - residual after contact time; free chlorine residual must be maintained at 0.2 mg/L minimum in distribution and detectable at all points.

  • Chlorine species distribution shifts with pH: HOCl dominates below pH 7.5, OCl- above pH 8.0; HOCl is about 80 times more effective as a disinfectant.

  • Chlorine decay in distribution follows first-order kinetics; k values of 0.1-0.5 per day are typical, and higher temperatures and lower pH accelerate decay.

  • Chloramines (NH2Cl) form when chlorine-to-ammonia ratio is about 5:1 by weight; monochloramine is a weaker but more persistent secondary disinfectant.

  • Ozone and UV require post-disinfection residual maintenance; UV provides no residual, so a secondary disinfectant must be applied downstream.

  • TTHM and HAA5 form from reactions between chlorine and natural organic matter; precursor removal by enhanced coagulation (TOC removal) is the primary control strategy.

  • Chlorine dioxide and ozone are strong oxidants but produce chlorite and bromate respectively; bromate MCL is 0.010 mg/L, chlorite MCL is 1.0 mg/L.

Quick reference

Corrosion Control and Water Quality Stability

  • Langelier Saturation Index (LSI) = pH - pHs; LSI near 0 is balanced, negative is corrosive, positive is scale-forming; typical target is -0.5 to +0.5.

  • pHs = (9.3 + A + B) - (C + D), where A = (log10 TDS - 1)/10, B = -13.12 × log10(°C + 273) + 34.55, C = log10(Ca as CaCO3) - 0.4, D = log10(alkalinity as CaCO3).

  • Lead and Copper Rule action levels: 0.015 mg/L lead and 1.3 mg/L copper at the 90th percentile; exceedance triggers corrosion control treatment or optimization.

  • Optimal corrosion control for lead is typically pH adjustment to 7.5-8.5 and addition of orthophosphate (1-3 mg/L as PO4) or blended phosphate to form a protective film.

  • Calcium carbonate precipitation (CaCO3) forms a protective scale; deposition requires positive LSI and adequate calcium hardness (typically > 60 mg/L as CaCO3).

  • Aggressive water indicators: low pH (< 7.0), low alkalinity (< 50 mg/L), low hardness, high chloride-to-sulfate mass ratio (CSMR > 0.5 increases galvanic corrosion risk).

  • Water stability monitoring includes pH, alkalinity, calcium hardness, LSI, and corrosion coupon or pipe loop studies for large systems.

  • Discolored water complaints often indicate iron or manganese release from corroded mains or sediment resuspension; flushing and corrosion control adjustments are typical responses.

Quick reference

Pumps, Motors, and Process Instrumentation

  • Pump power (kW) = (Q × H × ρ × g) / (3.6 × 10^6 × efficiency), where Q is in m3/h and H in meters; brake horsepower in US units = (gpm × ft × SG) / (3960 × efficiency).

  • Pump affinity laws: flow varies directly with speed, head with speed squared, and power with speed cubed; a 10% speed reduction cuts power by about 27%.

  • Specific speed Ns = N × √Q / H^0.75; low specific speed favors radial flow, high specific speed favors mixed or axial flow.

  • Best efficiency point (BEP) is where the pump operates most efficiently; operating far from BEP causes vibration, cavitation, and shortened seal or bearing life.

  • Net positive suction head available (NPSHA) must exceed NPSH required (NPSHR) by at least 1-2 feet to prevent cavitation; NPSHA = atmospheric pressure head + static suction head - friction loss - vapor pressure head.

  • Motor current imbalance greater than 10% indicates a voltage or winding problem; phase voltage imbalance should be held below 2%.

  • Instrumentation: 4-20 mA loops use 4 mA for zero and 20 mA for full span; a reading of 12 mA corresponds to 50% of span.

  • Turbidimeters must be calibrated with primary standards (formazin or AMCO AEPA-1) and verified with secondary standards; flow meters require periodic calibration checks against a master meter.

Quick reference

Laboratory Analysis, Sampling, and Process Control Calculations

  • Dose (mg/L) = (chemical feed rate in lb/day × 1,000,000) / (flow in MGD × 8.34); in metric, dose = (kg/day × 1000) / (m3/day).

  • Feed rate (lb/day) = dose (mg/L) × flow (MGD) × 8.34; for solutions, feed rate = (solution concentration %) × (specific gravity) × (solution flow).

  • Detention time (hours) = (basin volume in gallons × 24) / flow in gallons per day; for rectangular basins volume = length × width × depth.

  • Weir overflow rate (gpd/ft) = flow (gpd) / weir length (ft); surface loading rate (gpd/ft2) = flow / surface area.

  • Chlorine dose calculation: (desired residual + demand) × flow × 8.34 = lb/day of chlorine; hypochlorite solution strength varies with age and must be verified by titration.

  • Sample handling: coliform samples require 100 mL sterile bottles, sodium thiosulfate to neutralize chlorine, iced storage, and analysis within 6 hours (8 hours for some methods); hold time for nitrate is 48 hours.

  • Turbidity is reported in NTU; color in color units (CU); pH measured with a calibrated electrode using pH 4, 7, and 10 buffers.

  • Grab samples represent a single point in time; composite samples are flow-proportioned or time-proportioned and are used for calculating averages and loading.

Quick reference

Safety, Emergency Response, and Security

  • Chlorine gas is heavier than air and accumulates in low areas; the IDLH is 10 ppm, and the odor threshold is about 0.3 ppm; escape respirators are required when concentrations exceed 10 ppm.

  • Confined space entry requires atmospheric testing for oxygen (19.5-23.5%), flammables (< 10% LEL), and toxics (H2S < 10 ppm) before entry, plus a permit and attendant.

  • Lockout/tagout (LOTO) must isolate all energy sources before maintenance; verify zero energy state by attempting startup and testing for voltage.

  • Hazardous chemical storage: separate oxidizers (chlorine, permanganate) from acids and organics; secondary containment must hold 110% of the largest container volume.

  • Emergency response plan elements include vulnerability assessment, emergency contacts, alternate water supply, notification procedures, and annual drills.

  • Boil water notices are issued when pressure drops below 20 psi or when bacteriological contamination is confirmed; notices must include the reason, actions, and rescission criteria.

  • Security measures include fencing, locked hatches, intrusion alarms, and background checks for personnel with access to treatment chemicals.

  • Personal protective equipment for chemical handling includes chemical splash goggles, face shield, gloves, apron, and SCBA for chlorine gas response.

Quick reference

Records, Reporting, and Operator Certification Responsibilities

  • Consumer Confidence Report (CCR) must be delivered to customers by July 1 each year, covering the prior calendar year's monitoring results, violations, and source water information.

  • Monthly operating reports (MORs) summarize flows, chemical doses, residuals, turbidity, and compliance data; they must be submitted to the primacy agency by the 10th of the following month in California.

  • Operator certification in California is by grade (T1-T5 for treatment, D1-D5 for distribution); each grade requires specified experience, education, and passing an exam.

  • Continuing education: California requires 24 contact hours per 3-year renewal cycle for treatment operators, with specified subject categories.

  • Record retention: bacteriological and chemical monitoring results must be kept at least 5 years; turbidity and disinfection data at least 3 years; plans and specifications for the life of the facility.

  • Public notification for Tier 1 violations (e.g., MCL exceedance, treatment technique failure) within 24 hours; Tier 2 within 30 days; Tier 3 in the next CCR.

  • Sanitary surveys are required every 5 years for community water systems; significant deficiencies must be corrected within a specified schedule.

  • Chain of custody documentation is required for compliance samples, including collector name, date, time, sample location, and analysis requested.

Quick reference

Distribution System Interface and Finished Water Storage

  • Distribution system minimum pressure is 20 psi under normal conditions; below 20 psi requires a boil water notice and investigation.

  • Finished water storage tanks must maintain a minimum chlorine residual of 0.2 mg/L at all points; turnover of at least once every 5 days is recommended to prevent stagnation.

  • Tank inspection intervals: interior inspection every 5 years for steel tanks and every 3-5 years for concrete; exterior inspection annually.

  • Storage tank design includes cathodic protection, vent screening (to exclude birds and insects), overflow protection with flap valves, and locked access hatches.

  • Water age in storage is reduced by tank mixing (submerged inlet, baffles, or mixers); stratification can cause thermal layering and dead zones.

  • Distribution sampling sites must be representative; coliform monitoring frequency depends on population served (e.g., 1 sample per 1,000 people per month, minimum 1).

  • Cross-connection control requires backflow prevention devices (RPZ, DCVA, PVB) tested annually by certified testers; air gaps are the highest protection.

  • Hydrant flushing removes sediment and stale water; unidirectional flushing sequences from source to extremities improve effectiveness.