CA Branch 1 key terms
CA Branch 1 · Get comfortable with the vocabulary.
- Source water assessment
- Related: Watershed protection, Total coliform rule
A report identifying the origin of a system's water and the potential contaminant threats near it, used to prioritize monitoring and protection efforts. Required under the Safe Drinking Water Act.
- Watershed protection
- Related: Source water assessment, Raw water
Managing land use and activities in the drainage area supplying a reservoir or intake to keep contaminants out of raw water, reducing treatment cost and risk.
- Raw water
- Related: Turbidity, Coagulant dose
Untreated water as it enters the plant from a well, river, lake, or aqueduct, before any coagulation, filtration, or disinfection step is applied.
- Turbidity
- Related: Raw water, Filter run
The cloudiness of water caused by suspended particles that scatter light, measured in nephelometric turbidity units and used as a key indicator of filtration performance.
- Coagulant dose
- Related: Jar test, Flocculation
The amount of chemical such as alum, ferric chloride, or polyaluminum chloride added per volume of water to destabilize particles and begin floc formation.
- Jar test
- Related: Coagulant dose, Zeta potential
A bench-scale simulation in which several beakers of raw water receive different coagulant doses and mixing speeds, allowing operators to select the best chemical dose and pH.
- Zeta potential
- Related: Jar test, Flocculation
A measure of the electrical charge at the slipping plane around a particle; near zero indicates particles are destabilized and likely to stick together during flocculation.
- Flocculation
- Related: Coagulant dose, Settling velocity
Gentle, slow stirring after rapid mix that encourages destabilized particles to collide and grow into larger, settleable floc without breaking the flocs apart.
- Settling velocity
- Related: Flocculation, Surface overflow rate
The downward speed a particle reaches when drag balances its submerged weight; particles with higher settling velocity are removed more readily in a clarifier.
- Surface overflow rate
- Related: Settling velocity, Filter loading rate
The flow through a sedimentation basin divided by its surface area, expressed as flow per area per day; it sets the minimum settling velocity a basin can capture.
- Filter loading rate
- Related: Surface overflow rate, Filter run
The flow through a filter divided by its surface area, usually expressed in gallons per minute per square foot; higher rates reduce contact time and can worsen effluent quality.
- Filter run
- Related: Backwash, Turbidity
The period a filter operates between backwashes, during which head loss rises and effluent turbidity may creep upward as captured particles accumulate in the media.
- Backwash
- Related: Filter run, Filter-to-waste
Reversing flow upward through a filter at a rate that expands the media bed and flushes captured solids to waste, restoring the filter for another run.
- Filter-to-waste
- Related: Backwash, Turbidity
Diverting the first filtered water after backwash to drain until turbidity falls below a set limit, preventing a spike of particles from entering finished water.
- CT value
- Related: Disinfectant residual, Log inactivation
The product of disinfectant residual concentration and contact time, used to demonstrate that a required level of pathogen inactivation has been achieved.
- Log inactivation
- Related: CT value, Disinfection byproducts
A way of expressing pathogen reduction as powers of ten; two-log inactivation means 99 percent of the target organisms are destroyed, three-log means 99.9 percent.
- Disinfection byproducts
- Related: Total organic carbon, Disinfectant residual
Compounds such as trihalomethanes and haloacetic acids formed when chlorine reacts with natural organic matter; regulated because long-term exposure raises health concerns.
- Total organic carbon
- Related: Disinfection byproducts, Coagulant dose
The concentration of carbon bound in organic compounds in water; it is the precursor material for disinfection byproducts and is often reduced by coagulation or carbon adsorption.
- Disinfectant residual
- Related: CT value, Booster chlorination
The concentration of disinfectant remaining in treated water, maintained to protect against microbial regrowth and contamination as water travels through the distribution system.
- Booster chlorination
- Related: Disinfectant residual, Disinfection byproducts
Adding a small dose of chlorine at points in the distribution system to restore residual that has decayed, extending protection to distant or slow-moving areas.
- Langelier Saturation Index
- Related: Corrosion control, Lead and copper rule
A calculated number comparing measured pH to the pH at which water is exactly calcium carbonate saturated; near zero suggests balanced water, negative is corrosive, positive is scale-forming.
- Corrosion control
- Related: Langelier Saturation Index, Lead and copper rule
Adjusting pH, alkalinity, or adding inhibitors such as orthophosphate to keep pipe material from dissolving into finished water and to protect metal plumbing.
- Lead and copper rule
- Related: Corrosion control, Langelier Saturation Index
A regulation requiring systems to sample tap water at high-risk homes and, if action levels are exceeded, to optimize corrosion control and conduct public education.
- Pump curve
- Related: System curve, Cavitation
A graph of the head a pump can produce at various flow rates; the point where it crosses the system curve is the actual operating condition.
- System curve
- Related: Pump curve, Cavitation
A graph showing the head required to move water through a given piping network at each flow rate, combining static lift and friction losses.
- Cavitation
- Related: Net positive suction head, Pump curve
Vapor bubbles forming and collapsing inside a pump when suction pressure drops too low, causing noise, vibration, and damage to the impeller over time.
- Net positive suction head
- Related: Cavitation, Pump curve
The absolute pressure margin above a liquid's vapor pressure at the pump suction; too little available margin allows cavitation to begin.
- Calibration
- Related: Turbidimeter, Grab sample
Comparing an instrument's reading against a known standard and adjusting it so the displayed value matches the true value within an acceptable tolerance.
- Turbidimeter
- Related: Calibration, Turbidity
An instrument that shines light through a sample and measures scattered light to report turbidity; it must be calibrated and its sample cell kept clean and free of scratches.
- Grab sample
- Related: Composite sample, Chain of custody
A single volume collected at one place and time, giving an instant snapshot rather than an average; useful for process checks and for tests that cannot be composited.
- Composite sample
- Related: Grab sample, Chain of custody
Several portions collected over time or across locations and combined, producing an average result that may hide short-term peaks in quality.
- Chain of custody
- Related: Grab sample, Composite sample
A documented record of who collected, handled, and transported a sample and when, used to prove the sample's integrity if results are challenged.
- Detention time
- Related: CT value, Surface overflow rate
The theoretical average time water spends in a basin or pipe, calculated as volume divided by flow rate; used in disinfection and settling calculations.
- Confined space entry
- Related: Lockout tagout, Chlorine leak response
Entering a vault, tank, or pit with limited access and poor ventilation, requiring atmospheric testing, a permit, an attendant, and rescue provisions before anyone goes in.
- Lockout tagout
- Related: Confined space entry, Chlorine leak response
A procedure for isolating and locking energy sources before servicing equipment so that pumps or mixers cannot start unexpectedly and injure workers.
- Chlorine leak response
- Related: Confined space entry, Disinfectant residual
Evacuating upwind, calling for trained responders, and using respiratory protection and leak kits; never entering a gas cloud without proper equipment and backup.
- Consumer confidence report
- Related: Disinfection byproducts, Lead and copper rule
An annual notice telling customers where their water comes from, what contaminants were detected, and any health effects, delivered by a required deadline.
- Cross-connection
- Related: Backflow prevention, Finished water storage
Any actual or potential link between the drinking water supply and a source of contamination, prevented by air gaps, backflow preventers, and routine inspections.
- Backflow prevention
- Related: Cross-connection, Finished water storage
Devices and practices such as air gaps, reduced-pressure assemblies, and vacuum breakers that stop water from flowing backward into the potable system.
- Finished water storage
- Related: Disinfectant residual, Cross-connection
Tanks and reservoirs holding treated water for demand peaks and fire flow; they must be covered, inspected, and operated to keep water fresh and residual intact.