Source water assessment

A report identifying the origin of a system's water and the potential contaminant threats near it, used to prioritize monitoring and protection efforts. Required under the Safe Drinking Water Act.

Related: Watershed protection, Total coliform rule
Watershed protection

Managing land use and activities in the drainage area supplying a reservoir or intake to keep contaminants out of raw water, reducing treatment cost and risk.

Related: Source water assessment, Raw water
Raw water

Untreated water as it enters the plant from a well, river, lake, or aqueduct, before any coagulation, filtration, or disinfection step is applied.

Related: Turbidity, Coagulant dose
Turbidity

The cloudiness of water caused by suspended particles that scatter light, measured in nephelometric turbidity units and used as a key indicator of filtration performance.

Related: Raw water, Filter run
Coagulant dose

The amount of chemical such as alum, ferric chloride, or polyaluminum chloride added per volume of water to destabilize particles and begin floc formation.

Related: Jar test, Flocculation
Jar test

A bench-scale simulation in which several beakers of raw water receive different coagulant doses and mixing speeds, allowing operators to select the best chemical dose and pH.

Related: Coagulant dose, Zeta potential
Zeta potential

A measure of the electrical charge at the slipping plane around a particle; near zero indicates particles are destabilized and likely to stick together during flocculation.

Related: Jar test, Flocculation
Flocculation

Gentle, slow stirring after rapid mix that encourages destabilized particles to collide and grow into larger, settleable floc without breaking the flocs apart.

Related: Coagulant dose, Settling velocity
Settling velocity

The downward speed a particle reaches when drag balances its submerged weight; particles with higher settling velocity are removed more readily in a clarifier.

Related: Flocculation, Surface overflow rate
Surface overflow rate

The flow through a sedimentation basin divided by its surface area, expressed as flow per area per day; it sets the minimum settling velocity a basin can capture.

Related: Settling velocity, Filter loading rate
Filter loading rate

The flow through a filter divided by its surface area, usually expressed in gallons per minute per square foot; higher rates reduce contact time and can worsen effluent quality.

Related: Surface overflow rate, Filter run
Filter run

The period a filter operates between backwashes, during which head loss rises and effluent turbidity may creep upward as captured particles accumulate in the media.

Related: Backwash, Turbidity
Backwash

Reversing flow upward through a filter at a rate that expands the media bed and flushes captured solids to waste, restoring the filter for another run.

Related: Filter run, Filter-to-waste
Filter-to-waste

Diverting the first filtered water after backwash to drain until turbidity falls below a set limit, preventing a spike of particles from entering finished water.

Related: Backwash, Turbidity
CT value

The product of disinfectant residual concentration and contact time, used to demonstrate that a required level of pathogen inactivation has been achieved.

Related: Disinfectant residual, Log inactivation
Log inactivation

A way of expressing pathogen reduction as powers of ten; two-log inactivation means 99 percent of the target organisms are destroyed, three-log means 99.9 percent.

Related: CT value, Disinfection byproducts
Disinfection byproducts

Compounds such as trihalomethanes and haloacetic acids formed when chlorine reacts with natural organic matter; regulated because long-term exposure raises health concerns.

Related: Total organic carbon, Disinfectant residual
Total organic carbon

The concentration of carbon bound in organic compounds in water; it is the precursor material for disinfection byproducts and is often reduced by coagulation or carbon adsorption.

Related: Disinfection byproducts, Coagulant dose
Disinfectant residual

The concentration of disinfectant remaining in treated water, maintained to protect against microbial regrowth and contamination as water travels through the distribution system.

Related: CT value, Booster chlorination
Booster chlorination

Adding a small dose of chlorine at points in the distribution system to restore residual that has decayed, extending protection to distant or slow-moving areas.

Related: Disinfectant residual, Disinfection byproducts
Langelier Saturation Index

A calculated number comparing measured pH to the pH at which water is exactly calcium carbonate saturated; near zero suggests balanced water, negative is corrosive, positive is scale-forming.

Related: Corrosion control, Lead and copper rule
Corrosion control

Adjusting pH, alkalinity, or adding inhibitors such as orthophosphate to keep pipe material from dissolving into finished water and to protect metal plumbing.

Related: Langelier Saturation Index, Lead and copper rule
Lead and copper rule

A regulation requiring systems to sample tap water at high-risk homes and, if action levels are exceeded, to optimize corrosion control and conduct public education.

Related: Corrosion control, Langelier Saturation Index
Pump curve

A graph of the head a pump can produce at various flow rates; the point where it crosses the system curve is the actual operating condition.

Related: System curve, Cavitation
System curve

A graph showing the head required to move water through a given piping network at each flow rate, combining static lift and friction losses.

Related: Pump curve, Cavitation
Cavitation

Vapor bubbles forming and collapsing inside a pump when suction pressure drops too low, causing noise, vibration, and damage to the impeller over time.

Related: Net positive suction head, Pump curve
Net positive suction head

The absolute pressure margin above a liquid's vapor pressure at the pump suction; too little available margin allows cavitation to begin.

Related: Cavitation, Pump curve
Calibration

Comparing an instrument's reading against a known standard and adjusting it so the displayed value matches the true value within an acceptable tolerance.

Related: Turbidimeter, Grab sample
Turbidimeter

An instrument that shines light through a sample and measures scattered light to report turbidity; it must be calibrated and its sample cell kept clean and free of scratches.

Related: Calibration, Turbidity
Grab sample

A single volume collected at one place and time, giving an instant snapshot rather than an average; useful for process checks and for tests that cannot be composited.

Related: Composite sample, Chain of custody
Composite sample

Several portions collected over time or across locations and combined, producing an average result that may hide short-term peaks in quality.

Related: Grab sample, Chain of custody
Chain of custody

A documented record of who collected, handled, and transported a sample and when, used to prove the sample's integrity if results are challenged.

Related: Grab sample, Composite sample
Detention time

The theoretical average time water spends in a basin or pipe, calculated as volume divided by flow rate; used in disinfection and settling calculations.

Related: CT value, Surface overflow rate
Confined space entry

Entering a vault, tank, or pit with limited access and poor ventilation, requiring atmospheric testing, a permit, an attendant, and rescue provisions before anyone goes in.

Related: Lockout tagout, Chlorine leak response
Lockout tagout

A procedure for isolating and locking energy sources before servicing equipment so that pumps or mixers cannot start unexpectedly and injure workers.

Related: Confined space entry, Chlorine leak response
Chlorine leak response

Evacuating upwind, calling for trained responders, and using respiratory protection and leak kits; never entering a gas cloud without proper equipment and backup.

Related: Confined space entry, Disinfectant residual
Consumer confidence report

An annual notice telling customers where their water comes from, what contaminants were detected, and any health effects, delivered by a required deadline.

Related: Disinfection byproducts, Lead and copper rule
Cross-connection

Any actual or potential link between the drinking water supply and a source of contamination, prevented by air gaps, backflow preventers, and routine inspections.

Related: Backflow prevention, Finished water storage
Backflow prevention

Devices and practices such as air gaps, reduced-pressure assemblies, and vacuum breakers that stop water from flowing backward into the potable system.

Related: Cross-connection, Finished water storage
Finished water storage

Tanks and reservoirs holding treated water for demand peaks and fire flow; they must be covered, inspected, and operated to keep water fresh and residual intact.

Related: Disinfectant residual, Cross-connection