Power Eng 2nd Class flashcards
Power Eng 2nd Class · Build recall with a focused review session.
36 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Sensible heat
- Heat that changes the temperature of a substance without changing its phase. Calculated as Q = m × c_p × ΔT, with mass in kg, specific heat in kJ/kg·K, and temperature change in K.
- Steam quality
- The mass fraction of vapor in a wet steam mixture, from 0 at saturated liquid to 1 at saturated vapor. It is found from enthalpy using x = (h − h_f)/h_fg.
- Log mean temperature difference
- The driving temperature difference for a heat exchanger, calculated as the difference of the terminal differences divided by the natural log of their ratio. Used with the overall coefficient to size area.
- Carnot efficiency
- The maximum possible efficiency of a heat engine operating between two temperatures, equal to 1 minus the ratio of absolute sink temperature to absolute source temperature.
- NPSH available
- The absolute pressure head at the pump suction above the liquid vapor pressure. If it falls below the pump's required value, cavitation damages the impeller and reduces flow.
- Pump affinity laws
- For a centrifugal pump, flow varies with speed, head with speed squared, and power with speed cubed. Impeller diameter follows the same pattern for modest trims.
- Compressor clearance volume
- The volume remaining in the cylinder at the end of discharge. It traps gas that re-expands on the suction stroke, reducing volumetric efficiency as compression ratio rises.
- Turbine isentropic efficiency
- The ratio of actual enthalpy drop across the turbine to the enthalpy drop that would occur in an ideal isentropic expansion between the same inlet and exhaust pressures.
- Governor droop
- The percentage speed decrease from no load to full load for a governor. Zero droop is called isochronous and allows parallel machines to share load poorly without a droop setting.
- Excess air
- The air supplied beyond the theoretical stoichiometric requirement, expressed as a percentage. Too little causes carbon monoxide; too much raises stack heat loss.
- Drum swell and shrink
- Apparent drum level rises on load increase because steam bubbles expand, and falls on load decrease. It misleads single-element level control, so three-element control is used on large boilers.
- Indirect boiler efficiency
- Boiler efficiency found by subtracting all losses from 100 percent. Losses include dry flue gas, moisture in fuel and air, unburned carbon, radiation, and blowdown.
- Furnace purge
- A forced airflow through the furnace and gas passages before ignition to remove accumulated combustible gases. The manufacturer's specified purge time must be proven before fuel is admitted.
- Live zero signal
- A 4–20 mA transmitter output where 4 mA represents the zero value of the measured span. The offset allows detection of a broken wire or failed transmitter.
- Integral control action
- A control mode whose output changes in proportion to the accumulated error over time. It eliminates steady-state offset but can cause overshoot if the integral time is too short.
- Fail-safe valve position
- The valve position on loss of air or power, set by the actuator spring. Selection depends on which position leaves the process in the safest condition.
- Flame scanner
- A sensor, often ultraviolet or infrared, that proves the burner flame is present. Its signal must distinguish flame from hot refractory and trip fuel on loss of flame.
- Synchronous speed
- The rotating speed of a motor's magnetic field, equal to 120 times frequency divided by the number of poles. Induction motors run slightly slower by the amount of slip.
- Motor slip
- The difference between synchronous speed and actual rotor speed, expressed as a fraction of synchronous speed. Slip increases as the mechanical load on the motor increases.
- Star-delta starting
- A starting method that connects the motor windings in star for starting and delta for running. Starting current and torque are reduced to one third of direct-on-line values.
- Variable frequency drive
- A device that controls motor speed by varying supply frequency and voltage. Below base speed it holds a constant voltage-to-frequency ratio to maintain magnetic flux.
- Conductivity blowdown control
- Boiler blowdown is adjusted to keep dissolved solids, estimated by conductivity, within the manufacturer's limit. Excessive solids cause carryover, foaming, and scale.
- Oxygen pitting
- Localized corrosion caused by dissolved oxygen attacking steel, forming small deep pits. Controlled by deaeration and a chemical oxygen scavenger held at the specified residual.
- Caustic embrittlement
- Stress corrosion cracking of boiler steel caused by concentrated caustic in crevices and at stressed joints. Controlled by water chemistry limits and by avoiding caustic concentration.
- Coefficient of performance
- Refrigeration effect divided by work input for a refrigeration cycle. For an ideal Carnot refrigerator it equals the cold absolute temperature divided by the temperature difference.
- Refrigeration ton
- A cooling capacity equal to 12,000 Btu per hour, or about 3.517 kilowatts. It is the rate of heat removal needed to melt one ton of ice in 24 hours.
- Evaporator superheat
- The temperature rise of refrigerant vapor above its saturation temperature at the evaporator outlet. Adequate superheat protects the compressor from liquid slugging.
- Pressure dew point
- The temperature at which moisture condenses from compressed air at operating pressure. It must be below the lowest piping temperature to prevent liquid water in the lines.
- Predictive maintenance
- Maintenance scheduled from measured equipment condition, such as vibration, thermography, oil analysis, or ultrasound. It replaces fixed intervals with condition-based intervention.
- Vibration signature of imbalance
- A dominant vibration at one times running speed, usually radial, that grows with speed. Misalignment instead shows elevated two times running speed and axial one-times vibration.
- Management of change
- A formal procedure requiring review and approval before any change to equipment, process, or setpoints. It ensures hazards and code impacts are assessed before implementation.
- Safety valve set pressure
- The inlet pressure at which a safety valve begins to open. It must not exceed the maximum allowable working pressure of the protected equipment, and capacity must match the boiler rating.
- Lower explosive limit
- The lowest fuel concentration in air that will support combustion. Gas detection alarms typically trip at a fraction of the LEL to keep the atmosphere safely below the flammable range.
- Confined space oxygen limit
- Acceptable entry oxygen is between 19.5 and 23.5 percent. Below that range asphyxiation risk rises; above it, clothing and materials burn far more readily.
- Shift handover
- A documented and signed transfer of equipment status, open permits, abnormal conditions, and outstanding work between outgoing and incoming operators. It prevents lost information at shift change.
- Plant heat rate
- The thermal energy input required per unit of electrical output, usually Btu per kWh. A lower heat rate means better efficiency and is a key plant performance indicator.