Power Eng 2nd Class key terms
Power Eng 2nd Class · Get comfortable with the vocabulary.
- Enthalpy
- Related: Superheat, Rankine Cycle
A measure of the total energy in a fluid that combines its internal energy with the flow work needed to push it through a system. Used to track energy changes across boilers, turbines, and heat exchangers.
- Superheat
- Related: Saturation Temperature, Enthalpy
The amount by which steam temperature exceeds its saturation temperature at a given pressure. Superheated steam contains no entrained moisture and is used to protect turbine blades from erosion.
- Saturation Temperature
- Related: Superheat, Latent Heat
The temperature at which a liquid boils at a given pressure, or at which vapor condenses. It rises as pressure rises, so a boiler's steam temperature is fixed by its operating pressure.
- Latent Heat
- Related: Saturation Temperature, Enthalpy
The energy absorbed or released when a substance changes phase without changing temperature, such as water boiling into steam. It is much larger than sensible heat for the same mass.
- Rankine Cycle
- Related: Enthalpy, Condenser Vacuum
The idealized thermodynamic cycle describing steam power plants, comprising pumping, boiling, expansion through a turbine, and condensation. Efficiency gains come from higher steam pressure and temperature and lower condenser pressure.
- Heat Transfer Coefficient
- Related: Conduction, Fouling Factor
A number expressing how readily heat moves between a fluid and a surface per unit area and temperature difference. It depends on fluid velocity, properties, and whether flow is laminar or turbulent.
- Conduction
- Related: Heat Transfer Coefficient, Fouling Factor
Heat transfer through a solid material by molecular vibration, without bulk movement of the material. It is the dominant path for heat loss through boiler insulation and tube walls.
- Fouling Factor
- Related: Heat Transfer Coefficient, Conduction
An allowance added to heat exchanger design calculations for deposits that build up on surfaces and reduce heat transfer. It represents the extra resistance expected over time between cleanings.
- Centrifugal Pump
- Related: Net Positive Suction Head, Pump Curve
A pump that adds energy by spinning fluid outward from an impeller, converting velocity into pressure in the casing. It is the standard choice for high-volume boiler feed and cooling water service.
- Net Positive Suction Head
- Related: Cavitation, Centrifugal Pump
The margin of absolute pressure above a liquid's vapor pressure at the pump suction. Insufficient NPSH causes cavitation, which damages impellers and erodes performance.
- Cavitation
- Related: Net Positive Suction Head, Pump Curve
The formation and collapse of vapor bubbles in a liquid when local pressure drops below vapor pressure. It produces noise, vibration, and pitting damage on pump impellers and turbine blades.
- Pump Curve
- Related: Centrifugal Pump, Cavitation
A graph of head versus flow rate for a given pump at a fixed speed. The operating point is where this curve intersects the system resistance curve.
- Surge
- Related: Compressor Staging, Thrust Bearing
An unstable condition in compressors or fans where flow reverses cyclically because discharge pressure exceeds what the machine can sustain. It causes violent vibration and can damage bearings and blades.
- Thrust Bearing
- Related: Surge, Critical Speed
A bearing designed to carry axial loads along a rotating shaft, common in turbines and compressors. Failure causes rotor shift, which can trigger high-vibration trips and severe internal damage.
- Critical Speed
- Related: Thrust Bearing, Vibration Monitoring
A rotational speed at which a shaft's natural frequency matches running speed, producing resonance and amplified vibration. Operators must pass through these bands quickly during startup and shutdown.
- Drum Level Three-Element Control
- Related: Shrink and Swell, Feedwater Control Valve
A boiler feedwater control strategy using steam flow, feedwater flow, and drum level signals. It compensates for shrink and swell so feedwater responds to true mass balance rather than level illusion.
- Shrink and Swell
- Related: Drum Level Three-Element Control, Feedwater Control Valve
Apparent changes in boiler drum level caused by pressure shifts that alter steam bubble volume in the water. Level can read falsely high or low even when water mass is unchanged.
- Feedwater Control Valve
- Related: Drum Level Three-Element Control, Shrink and Swell
The final control element regulating flow from the feed pump into the boiler. It must withstand high differential pressure and provide tight, stable positioning to keep drum level within limits.
- Programmable Logic Controller
- Related: Interlock, Distributed Control System
An industrial computer that executes ladder or function-block logic to control equipment and interlocks. It reads sensors, drives outputs, and enforces permissives that protect boilers and rotating machinery.
- Interlock
- Related: Programmable Logic Controller, Flame Scanner
A hardwired or programmed condition that prevents or forces an action to protect equipment and people. Examples include low-water cutoff trips and flame failure shutdowns.
- Flame Scanner
- Related: Burner Management System, Interlock
A sensor that verifies a burner flame is present by detecting ultraviolet or infrared radiation. It signals the burner management system to trip fuel if flame is lost.
- Burner Management System
- Related: Flame Scanner, Furnace Purge
The safety system that sequences burner startup, monitors flame, and shuts off fuel on unsafe conditions. It enforces purge, light-off, and trip requirements defined by code.
- Furnace Purge
- Related: Burner Management System, Flame Scanner
A forced airflow period before ignition that clears combustible gases from the furnace and gas passages. It must run at specified airflow for a set time to prevent explosion on light-off.
- Stoichiometric Combustion
- Related: Excess Air, Flue Gas Analysis
Burning fuel with exactly the theoretical amount of air needed for complete oxidation. In practice boilers run with excess air to ensure complete combustion and limit carbon monoxide.
- Excess Air
- Related: Stoichiometric Combustion, Flue Gas Analysis
Air supplied beyond the theoretical requirement for complete combustion. Too little produces carbon monoxide and smoke; too much wastes heat by raising stack losses.
- Flue Gas Analysis
- Related: Excess Air, Stoichiometric Combustion
Measurement of oxygen, carbon monoxide, and carbon dioxide in exhaust gases to judge combustion efficiency. Oxygen readings are used to trim excess air to the optimum.
- Condenser Vacuum
- Related: Rankine Cycle, Air In-Leakage
The sub-atmospheric pressure maintained in a steam condenser by removing air and condensing steam. Better vacuum lowers turbine exhaust pressure and raises cycle efficiency.
- Air In-Leakage
- Related: Condenser Vacuum, Deaerator
Unwanted entry of air into a condenser or vacuum system through seals, joints, or fittings. It degrades vacuum, raises dissolved oxygen, and increases back pressure on the turbine.
- Deaerator
- Related: Oxygen Pitting, Air In-Leakage
A vessel that heats feedwater and strips dissolved oxygen and other gases by steam scrubbing. Removing oxygen protects boiler tubes and downstream piping from corrosion.
- Oxygen Pitting
- Related: Deaerator, Scale
Localized corrosion caused by dissolved oxygen attacking steel at discrete points, forming deep pits. It is prevented by deaeration and chemical oxygen scavengers.
- Scale
- Related: Oxygen Pitting, Blowdown
Hard mineral deposits such as calcium carbonate that form on heat transfer surfaces. Scale insulates tubes, raises metal temperatures, and can cause overheating failures.
- Blowdown
- Related: Scale, Carryover
Deliberate removal of boiler water to control dissolved solids and sludge concentration. Excess blowdown wastes energy; too little leads to carryover and foaming.
- Carryover
- Related: Blowdown, Superheat
Contamination of steam by boiler water droplets or foam, carrying dissolved solids into superheaters and turbines. It causes deposits, corrosion, and loss of superheat.
- Refrigerant Superheat
- Related: Subcooling, Compressor Staging
The temperature rise of refrigerant vapor above its saturation point at the evaporator outlet. It confirms complete evaporation and protects the compressor from liquid slugging.
- Subcooling
- Related: Refrigerant Superheat, Compressor Staging
The amount by which liquid refrigerant at the condenser outlet is cooled below its saturation temperature. It indicates adequate charge and ensures solid liquid reaches the expansion device.
- Compressor Staging
- Related: Surge, Subcooling
Operating multiple compressor stages or units in series or parallel to match load and pressure ratio. Staging improves efficiency and avoids surging at low demand.
- Lockout/Tagout
- Related: Interlock, Confined Space Entry
A procedure that isolates energy sources and applies locks and tags before maintenance, preventing accidental startup or release of stored energy. It is a core requirement for safe equipment work.
- Confined Space Entry
- Related: Lockout/Tagout, Flue Gas Analysis
Entry into a space with limited access and poor ventilation that may contain hazardous atmosphere. It requires testing, permits, attendants, and rescue provisions before entry.
- Vibration Monitoring
- Related: Critical Speed, Thrust Bearing
Continuous or periodic measurement of machine vibration to detect imbalance, misalignment, bearing wear, and looseness. Trending allows faults to be corrected before failure.
- Distributed Control System
- Related: Programmable Logic Controller, Drum Level Three-Element Control
A networked control platform with distributed processors and operator workstations that manages plant loops and alarms. It provides centralized monitoring while keeping control local to equipment areas.