Power Eng 5th Class key terms
Power Eng 5th Class · Get comfortable with the vocabulary.
- Working pressure
- Related: Safety valve, Hydrostatic test
The maximum pressure at which a boiler or pressure vessel is designed and permitted to operate under normal service, stamped on the nameplate and used as the basis for safety valve settings and inspection intervals.
- Safety valve
- Related: Working pressure, Try lever test
A spring-loaded automatic valve that opens at a set pressure to release steam or vapour and prevent a boiler from exceeding its maximum allowable working pressure. It reseats automatically as pressure falls.
- Hydrostatic test
- Related: Working pressure, Corrosion allowance
A pressure test in which the vessel is filled with water and pressurised above its working pressure to prove strength and tightness. Water is used because it stores little energy if the vessel ruptures.
- Corrosion allowance
- Related: Hydrostatic test, Caustic embrittlement
Extra metal thickness built into a boiler or vessel wall beyond what is needed for strength, so that predictable metal loss from corrosion or erosion over the service life does not reduce the wall below the safe minimum.
- Water column
- Related: Gauge glass, Low-water fuel cutoff
A vertical fitting on a boiler connected to the steam and water spaces that dampens surges so the gauge glass and low-water cutoff see a steady level rather than the churning surface inside the drum.
- Gauge glass
- Related: Water column, Low-water fuel cutoff
A transparent tube or flat glass assembly connected to a boiler's water and steam spaces so the operator can directly observe the water level. It must be blown down and checked regularly to stay reliable.
- Low-water fuel cutoff
- Related: Gauge glass, Water column
A safety control that senses boiler water level and shuts off the fuel supply if the level falls below a safe minimum, preventing overheating and catastrophic failure of the pressure vessel.
- Try lever test
- Related: Safety valve
A manual check of a safety valve in which the lever is lifted briefly while the boiler is under pressure to confirm the valve opens freely and reseats without sticking. Done with care to avoid damage.
- Blowdown
- Related: Total dissolved solids, Foaming
The controlled release of water from a boiler to remove dissolved solids and sludge that accumulate as steam is generated. Bottom blowdown removes sludge; surface blowdown controls dissolved solids concentration.
- Priming and foaming
- Related: Blowdown, Total dissolved solids
Priming is carryover of boiler water droplets into the steam outlet; foaming is a stable froth on the water surface that promotes it. Both are worsened by high dissolved solids, oil, or sudden load changes.
- Stoichiometric combustion
- Related: Excess air, Flue gas analysis
Combustion in which exactly the theoretically correct quantity of air is supplied to burn all the fuel, leaving no excess oxygen and no unburned fuel. In practice some excess air is always needed.
- Excess air
- Related: Stoichiometric combustion, Flue gas analysis
Air supplied to a burner beyond the theoretical amount needed for complete combustion, expressed as a percentage. Enough ensures complete burning; too much wastes heat up the stack and lowers efficiency.
- Flue gas analysis
- Related: Excess air, Stoichiometric combustion
Measurement of oxygen, carbon dioxide, carbon monoxide and temperature in the exhaust gas to judge combustion quality. It reveals whether the burner runs lean, rich, or with excessive air and heat loss.
- Flame safeguard
- Related: Purge, Furnace explosion
A control system that proves a flame is present before fuel is admitted and shuts the fuel off if the flame is lost, preventing explosive accumulation of unburned fuel in the furnace.
- Purge
- Related: Flame safeguard, Furnace explosion
A timed flow of air through the furnace and gas passages before ignition to sweep out any accumulated combustible gases, typically several air changes, so light-off cannot cause an explosion.
- Furnace explosion
- Related: Purge, Flame safeguard
A violent ignition of unburned fuel that has collected in the furnace or flue, usually caused by failed purging, loss of flame without fuel shutoff, or repeated failed light-off attempts.
- Three-element level control
- Related: Shrink and swell, Feedwater regulator
Feedwater control that uses drum level, steam flow and feedwater flow signals together. Steam flow anticipates demand and feedwater flow corrects the response, avoiding the shrink and swell errors of level-only control.
- Shrink and swell
- Related: Three-element level control
Apparent changes in boiler drum level caused by pressure changes, not by real changes in water quantity. A sudden steam demand drops pressure, makes steam bubbles expand, and the level falsely rises.
- Feedwater regulator
- Related: Three-element level control
The valve and actuator assembly that adjusts feedwater flow into a boiler in response to level or flow signals, maintaining drum level within limits across the load range.
- Total dissolved solids
- Related: Blowdown, Priming and foaming
The concentration of dissolved salts and minerals in boiler water, measured in parts per million. It is controlled by blowdown because excessive levels cause carryover, scale, and corrosion.
- Scale
- Related: Water softener, Caustic embrittlement
A hard crust of mineral deposits, mainly calcium and magnesium salts, that forms on hot boiler surfaces. It insulates the metal, causing overheating, tube failure, and wasted fuel.
- Water softener
- Related: Scale, Deaerator
An ion exchange unit that swaps hardness ions such as calcium and magnesium for sodium, preventing scale formation in the boiler. The resin is restored by regenerating with brine.
- Deaerator
- Related: Oxygen pitting, Water softener
A vessel that heats feedwater with steam under pressure to drive off dissolved oxygen and carbon dioxide, which would otherwise cause pitting and corrosion in the boiler and condensate system.
- Oxygen pitting
- Related: Deaerator
Localised corrosion in the form of small deep cavities on boiler and condensate piping metal, caused by dissolved oxygen. It is prevented by deaeration and chemical oxygen scavengers.
- Caustic embrittlement
- Related: Scale, Corrosion allowance
Cracking of stressed boiler steel caused by concentrated caustic soda in crevices and seams. It is controlled by limiting alkalinity, avoiding over-concentration, and good water treatment practice.
- Cavitation
- Related: Net positive suction head, Centrifugal pump
Formation and collapse of vapour bubbles in a pump when local pressure drops below the liquid's vapour pressure. It causes noise, vibration, and erosion of the impeller and reduces flow.
- Net positive suction head
- Related: Cavitation, Centrifugal pump
The absolute pressure margin above a liquid's vapour pressure available at a pump suction. Adequate NPSH available over NPSH required prevents cavitation and loss of pumping.
- Centrifugal pump
- Related: Cavitation, Net positive suction head
A pump that adds energy to liquid by spinning it outward from an impeller inside a casing. It produces high flow at moderate head and is the most common boiler feed and circulating pump type.
- Reciprocating pump
- Related: Centrifugal pump
A positive displacement pump using a piston or plunger moving in a cylinder to push liquid. It delivers a nearly constant flow against high pressure regardless of head, suiting small high-pressure feed duties.
- Air compressor unloading
- Related: Receiver
A control method that lets a compressor run with its intake valve closed or held open so it produces no air while the receiver is at pressure, reducing starting load and cycling wear.
- Receiver
- Related: Air compressor unloading
A pressure vessel that stores compressed air, smoothing pulsations from the compressor and allowing it to run in efficient cycles rather than constantly matching demand.
- Thermostatic expansion valve
- Related: Superheat, Evaporator
A refrigerant metering device that controls flow into an evaporator to maintain a set superheat at the outlet, using a bulb sensing suction line temperature to move the valve.
- Superheat
- Related: Thermostatic expansion valve, Evaporator
The temperature of refrigerant vapour above its saturation temperature at a given pressure. Measured at the evaporator outlet, it confirms the refrigerant has fully boiled and no liquid reaches the compressor.
- Evaporator
- Related: Thermostatic expansion valve, Superheat
The heat exchanger in a refrigeration system where low-pressure liquid refrigerant absorbs heat from the space or process and boils into vapour, producing the cooling effect.
- Psychrometric chart
- Related: Relative humidity
A graph relating dry-bulb temperature, wet-bulb temperature, humidity ratio, relative humidity and enthalpy of moist air, used to analyse heating, cooling, humidifying and dehumidifying processes in buildings.
- Relative humidity
- Related: Psychrometric chart
The amount of water vapour in air expressed as a percentage of the maximum the air can hold at that temperature. It affects comfort, condensation risk, and the load on cooling coils.
- Lockout and tagout
- Related: Confined space entry
A safety procedure in which energy sources are isolated, locked, and tagged before maintenance, ensuring equipment cannot be started or energised while someone is working on it.
- Confined space entry
- Related: Lockout and tagout
Entering an enclosed area such as a boiler drum or vessel with restricted access, requiring atmosphere testing, isolation, ventilation, an attendant, and a permit before anyone goes in.
- Megaohm
- Related: Ohm's law
A unit equal to one million ohms, used to express very high resistance. Insulation resistance of motors and cables is measured in megaohms to confirm the insulation has not broken down.
- Ohm's law
- Related: Megaohm
The relationship stating that voltage equals current multiplied by resistance in a circuit. It is the basis for calculating load current, voltage drop, and protective device ratings in plant electrical work.