Mistake 1

Accepting a reading without its reference and load condition

A number can be technically correct but irrelevant to the required operating condition.

What to do instead

Record the point, units, reference and actual load with the measured value.

Mistake 2

Mixing input rate and energy quantity

A rate includes time and cannot be substituted directly for a total quantity.

What to do instead

Write units and the governing relationship before calculating.

Mistake 3

Sizing a common section for only the largest appliance

The section may carry several connected loads simultaneously under the sizing assumptions.

What to do instead

Identify all downstream loads and the applicable diversity provisions, if any.

Mistake 4

Treating physical thread fit as complete component compatibility

A fitting part may have unsuitable fuel, pressure, temperature or approval characteristics.

What to do instead

Compare the complete required specifications and approved application.

Mistake 5

Using flame colour as the only combustion test

Appearance cannot quantify every hazardous combustion condition.

What to do instead

Use the specified observations and representative instrument measurements together.

Mistake 6

Ignoring building exhaust during draft assessment

The building pressure can change the appliance’s venting behaviour.

What to do instead

Assess the specified operating combinations and replacement-air provisions.

Mistake 7

Replacing a safety with a less restrictive device to stop trips

The trip may correctly indicate another fault, and changing the protection can conceal it.

What to do instead

Trace the cause and use the specified compatible replacement only when needed.

Mistake 8

Assuming thermostat demand is flame proof

A call for heat does not show that combustion was established.

What to do instead

Follow the actual ignition and flame-proving sequence.

Mistake 9

Calling one successful ignition a completed commissioning

Other operating, shutdown and protective functions remain unverified.

What to do instead

Complete the specified commissioning checks and record their conditions and results.

Mistake 10

Returning equipment to service without testing the repair

A correct new part can still be misapplied or installed incorrectly.

What to do instead

Verify the affected functions and communicate any remaining restrictions.