CA Water Operator · Keep the key ideas within reach.

Quick reference

Source Water and Water Quality

  • Surface water quality varies with runoff, temperature, and watershed land use; turbidity and pathogen risk often rise sharply during storms.

  • Groundwater is generally more stable in quality but can contain nitrate, arsenic, radionuclides, or salt from intrusion and must be monitored at the wellhead.

  • Turbidity is measured in nephelometric turbidity units (NTU) and indicates light scattering by particles; it is not a direct pathogen measurement.

  • TOC (total organic carbon) is a key DBP precursor: higher TOC generally increases THM and HAA formation potential when chlorine is used.

  • Alkalinity, reported as mg/L CaCO3, buffers pH; low-alkalinity water is more vulnerable to pH swings during coagulation and corrosion control.

  • The pH scale runs 0–14; values below 7 are acidic and often corrosive, while values above 7 are basic and can promote scaling.

  • The Surface Water Treatment Rule requires filtration and disinfection for most surface water sources; groundwater under direct influence may be regulated as surface water.

  • Source water protection uses watershed surveys, wellhead protection areas, and contaminant source inventories to reduce treatment burden and risk.

Quick reference

Treatment Processes (Coagulation, Flocculation, Sedimentation, Filtration)

  • Coagulation destabilizes particle and NOM charges; common coagulants include alum, ferric chloride, ferric sulfate, and polyaluminum chloride.

  • Rapid mix disperses coagulant in seconds with high-intensity mixing; flocculation uses gentle mixing for minutes to grow flocs without shearing them.

  • Jar tests compare coagulant doses and pH values; select the lowest dose that gives clear settled water, good floc, and acceptable filter run length.

  • Sedimentation removes settleable flocs; performance depends on surface loading rate, detention time, flow distribution, and floc density and size.

  • Surface loading rate = flow ÷ clarifier surface area; lower loading rates generally improve settling and effluent clarity.

  • Granular filters remove particles by straining, interception, sedimentation, and adsorption; backwash on head loss, turbidity breakthrough, or run time.

  • Filter loading rate = flow ÷ filter area; exceeding design rate can shorten runs, increase turbidity, and push particles through the media.

  • Chemical feed: lb/day = mg/L × MGD × 8.34; dose (mg/L) = lb/day ÷ (MGD × 8.34).

Quick reference

Disinfection and Disinfection Byproducts

  • CT = disinfectant concentration (mg/L) × effective contact time (min); use T10 and adjust for pH, temperature, and baffling.

  • Chlorine demand = applied dose − residual after contact; demand comes from organics, ammonia, metals, and other reducing agents.

  • Free chlorine reacts with ammonia to form chloramines; monochloramine persists longer but is a weaker disinfectant and can nitrify.

  • THMs and HAAs form when chlorine reacts with natural organic matter; control by TOC removal, enhanced coagulation, pH control, or alternative disinfectants.

  • Ozone is a strong disinfectant and oxidant but can form bromate when bromide is present; it provides no distribution residual.

  • UV disinfection damages nucleic acids and is effective against Cryptosporidium; it requires low turbidity and provides no residual.

  • Maintain disinfectant residual through distribution; residual loss can indicate nitrification, contamination, or excessive water age.

  • DPD testing measures free and total chlorine; total chlorine minus free chlorine estimates combined chlorine.

Quick reference

Distribution System Operations, Storage, and Cross-Connection Control

  • Air gap = highest backflow protection; testable assemblies include RPZ (high hazard), DCVA, and PVB; selection depends on hazard and local code.

  • Backflow occurs by backsiphonage (negative supply pressure) or backpressure (downstream pressure higher than supply).

  • Cross-connection control uses containment at the service line and isolation at fixtures; assemblies require annual testing and records.

  • Unidirectional flushing uses sequenced valves to achieve high velocity in one direction and remove sediment and biofilm.

  • Water age increases in oversized storage and low-demand areas; high age lowers residual and raises DBP and nitrification risk.

  • Chloraminated systems monitor free ammonia, nitrite, and residual; a free ammonia rise can signal nitrification.

  • Storage tanks need turnover, inspection, vent screening, overflow protection, and protection from intrusion; poor tank condition can degrade water quality.

  • Water hammer is a pressure surge from rapid flow change; air valves, surge tanks, and slow valve operation reduce surge damage.

Quick reference

Pumps, Motors, Meters, and Instrumentation

  • Total dynamic head (TDH) = elevation head + pressure head + velocity head + friction losses; the pump must overcome TDH at design flow.

  • Water horsepower = (gpm × TDH ft) ÷ 3960; brake horsepower = water horsepower ÷ pump efficiency.

  • 1 psi = 2.31 ft of water; 1 ft of water = 0.433 psi.

  • Affinity laws at constant impeller diameter: flow ∝ speed, head ∝ speed², power ∝ speed³.

  • Cavitation occurs when NPSH available is less than NPSH required; symptoms include noise, vibration, and impeller pitting.

  • Centrifugal pump operating point is where the pump curve intersects the system curve; throttling changes the system curve and flow.

  • Positive displacement pumps deliver nearly constant flow against varying pressure and require a relief valve for protection.

  • 4–20 mA transmitter: 4 mA = 0%, 20 mA = 100%; calibrate zero and span and verify loop power and grounding.

Quick reference

Regulations, Monitoring, Reporting, and Safety

  • SDWA sets national drinking water rules; in California, the State Water Resources Control Board, Division of Drinking Water, enforces primacy requirements.

  • Nitrate MCL = 10 mg/L as N; arsenic MCL = 10 µg/L; lead action level = 0.015 mg/L and copper action level = 1.3 mg/L.

  • Stage 2 DBPR MCLs: TTHM = 0.080 mg/L LRAA; HAA5 = 0.060 mg/L LRAA.

  • Total coliform positives require repeats within 24 hours; E. coli-positive results trigger additional repeat, assessment, and public notification requirements.

  • Consumer Confidence Report must be delivered to customers by July 1 each year and summarize detected contaminants and regulated limits.

  • Public notification has three tiers; Tier 1 is immediate for acute health risks, Tier 2 within 30 days, Tier 3 within one year.

  • Sample integrity requires proper containers, preservation, hold times, and chain-of-custody records; deviations can invalidate results.

  • Permit-required confined space entry needs atmospheric testing, ventilation, attendant, retrieval system, and trained rescue; LOTO controls hazardous energy.

  • Chlorine gas is heavier than air and hazardous; use gas detection and respiratory protection, and never use oil on chlorine equipment.