CA Water Operator study materials
CA Water Operator study resources

CA Water Operator key terms

CA Water Operator · Get comfortable with the vocabulary.

Turbidity

The cloudiness of water caused by suspended particles that scatter light. Measured in nephelometric turbidity units (NTU), it indicates filtration performance and can shield pathogens from disinfection.

Related: Raw water, Filter media, CT
Watershed

The land area that drains rainfall and snowmelt into a river, lake, or reservoir. Land uses and activities within a watershed shape the quality of the source water a treatment plant must handle.

Related: Raw water, Turbidity
Raw water

Untreated water as it arrives at a treatment plant from a well, river, lake, or reservoir. Operators test raw water quality to decide which treatment processes and chemical doses are needed.

Related: Turbidity, Coagulation
Alkalinity

The water's capacity to neutralize acid, contributed mainly by bicarbonate, carbonate, and hydroxide. It buffers pH and affects how much coagulant is needed and how corrosive finished water may become.

Related: Coagulation, Jar test
Groundwater under the direct influence of surface water (GWUDI)

A groundwater source influenced by nearby surface water, as shown by site conditions or water quality. It must be treated like surface water, typically requiring filtration and disinfection.

Related: Raw water, Watershed
Total coliform bacteria

A group of organisms used as indicators of treatment effectiveness and distribution system integrity. Their presence suggests a breach or contamination, though most coliforms do not themselves cause illness.

Related: Turbidity, Sanitary survey
Nitrate

A nitrogen compound common in agricultural groundwater and linked to blue baby syndrome. It has a primary drinking water standard and is monitored at the source before blending or treatment.

Related: Maximum contaminant level (MCL), Raw water
Coagulation

The rapid mixing of a chemical such as alum into water to neutralize particle charges so tiny suspended solids can stick together. It is the first step in conventional clarification.

Related: Flocculation, Jar test, Alkalinity
Flocculation

Gentle, slow stirring that encourages small destabilized particles to collide and grow into larger, settleable masses. It follows coagulation and precedes sedimentation in a conventional plant.

Related: Coagulation, Floc
Floc

The visible clump of particles formed when coagulated solids bind together. Well-formed floc settles quickly and is removed in clarifiers and filters rather than passing into finished water.

Related: Flocculation, Sedimentation basin
Sedimentation basin

A tank where water moves slowly enough for floc and other solids to settle to the bottom as sludge. Also called a clarifier, it removes most solids before filtration.

Related: Floc, Filter media
Jar test

A bench procedure that stirs several beakers of raw water with different coagulant doses and compares settling and turbidity. Operators use the results to set chemical feed rates.

Related: Coagulation, Alkalinity
Filter media

Layers of granular material such as anthracite, sand, and garnet that water passes through to remove remaining particles. Media type, size, and depth determine filtration performance.

Related: Backwash, Turbidity
Backwash

Reversing flow upward through a filter at a high rate to expand the media and wash out trapped solids. It restores capacity and is triggered by headloss, turbidity, or time set points.

Related: Filter media, Headloss
Headloss

The drop in pressure or water level caused by friction as water moves through filters, pipes, or fittings. Rising filter headloss signals that the filter needs backwashing.

Related: Backwash, Pump curve
CT value

The product of disinfectant concentration and contact time used to express disinfection strength against pathogens. Required CT depends on pH, temperature, and the target organism.

Related: Free chlorine residual, Turbidity
Free chlorine residual

The concentration of uncombined chlorine remaining after demand is satisfied. It protects water in the distribution system and is measured routinely at plants and throughout the pipe network.

Related: Chlorine demand, Water age
Chlorine demand

The amount of chlorine consumed by organic matter, metals, ammonia, and other reducing substances in water. The applied dose must exceed demand before any free residual remains.

Related: Free chlorine residual, Chloramine
Total organic carbon (TOC)

A measure of natural and human-made organic material in water. Organics react with disinfectants to form byproducts, so many plants remove TOC through coagulation and filtration.

Related: Total trihalomethanes (TTHM), Coagulation
Total trihalomethanes (TTHM)

A group of regulated disinfection byproducts, including chloroform, formed when chlorine reacts with organic matter. Compliance is judged by running annual averages of samples from the distribution system.

Related: Total organic carbon (TOC), Chloramine
Chloramine

A disinfectant made by combining chlorine with ammonia. It persists longer in pipes and forms fewer regulated byproducts, but it is a weaker primary disinfectant and needs careful process control.

Related: Chlorine demand, Total trihalomethanes (TTHM)
Cross-connection

Any actual or potential link between a potable water system and a source of contamination or pollution. Removing or protecting cross-connections prevents backflow from degrading drinking water.

Related: Backflow, Air gap, Sanitary survey
Backflow

Reverse flow of nonpotable water into a drinking water system, caused by backsiphonage or backpressure. It can contaminate the main and is prevented by air gaps and backflow prevention assemblies.

Related: Cross-connection, Reduced pressure principle assembly
Air gap

A physical separation between a potable water outlet and the flood rim of a receiving vessel. It is the most reliable backflow protection because it has no mechanical parts to fail.

Related: Backflow, Cross-connection
Reduced pressure principle assembly

A testable backflow preventer with two check valves and a relief valve, used where hazard is high. It guards against both backsiphonage and backpressure and requires periodic testing.

Related: Backflow, Cross-connection
Water age

The average time water has spent in the distribution system since leaving the treatment plant. High water age lowers disinfectant residual and increases byproduct formation and stagnation problems.

Related: Storage tank turnover, Free chlorine residual
Storage tank turnover

How often the volume of water in a storage tank is replaced by new flow. Poor turnover leaves old, stagnant water that loses residual and may develop biofilm and sediment.

Related: Water age, Free chlorine residual
Pump curve

A graph showing the flow rate and head a pump can produce across its operating range. Operators compare it with the system curve to find the point where the pump actually runs.

Related: Cavitation, Affinity laws
Cavitation

The formation and collapse of vapor bubbles in a pump when local pressure falls too low, causing noise, vibration, and metal damage. Avoiding it requires adequate net positive suction head.

Related: Net positive suction head (NPSH), Pump curve
Net positive suction head (NPSH)

The absolute pressure available at a pump suction above the liquid's vapor pressure. Too little NPSH causes cavitation, reduced capacity, and damage to the impeller.

Related: Cavitation, Pump curve
Affinity laws

Equations predicting how changing pump speed or impeller diameter changes flow, head, and power. Flow varies with speed, head with the square of speed, and power with the cube.

Related: Pump curve, Cavitation
Magnetic flow meter

A meter with no moving parts that measures flow from the voltage induced as conductive water passes through a magnetic field. It is accurate and widely used for plant and well flow measurement.

Related: Pump curve, Pressure reducing valve
Pressure reducing valve

A valve that lowers incoming pressure to a set downstream value. It protects distribution piping and customer plumbing from excessive pressure that causes leaks and accelerated wear.

Related: Magnetic flow meter, Pump curve
Maximum contaminant level (MCL)

The highest concentration of a contaminant allowed in drinking water under the Safe Drinking Water Act. Primary MCLs are enforceable health-based limits set as close to goals as feasible.

Related: Treatment technique, Nitrate
Treatment technique

A required treatment process rather than a contaminant concentration limit, used when measuring the contaminant is impractical. Filtration and corrosion control are common examples with enforceable requirements.

Related: Maximum contaminant level (MCL), Lead and Copper Rule
Consumer Confidence Report (CCR)

An annual report that community water systems must deliver to customers, describing source water, detected contaminants, and compliance status. It is a public right-to-know document.

Related: Maximum contaminant level (MCL), Sanitary survey
Revised Total Coliform Rule (RTCR)

Rules governing coliform monitoring and response in distribution systems. Repeat positive samples trigger a sanitary survey or assessment and corrective action instead of an automatic violation.

Related: Total coliform bacteria, Sanitary survey
Lead and Copper Rule

Requires sampling tap water at high-risk homes and applying corrosion control when action levels are exceeded. It targets pipe corrosion rather than treating lead directly.

Related: Treatment technique, Alkalinity
Confined space

A space large enough to enter, with limited entry and exit, that is not designed for continuous occupancy. Entry requires a permit, atmospheric testing, and an attendant to prevent asphyxiation or entrapment.

Related: Sanitary survey
Sanitary survey

A periodic on-site review by the state of a water system's sources, facilities, and operations to find sanitary defects. Identified problems must be corrected within set timeframes.

Related: Cross-connection, Total coliform bacteria, Revised Total Coliform Rule (RTCR)