COHC study materials
COHC study resources

COHC flashcards

COHC · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

OSHA action level
The OSHA hearing conservation action level is an 8-hour time-weighted average of 85 dBA, which triggers a hearing conservation program for exposed employees.
OSHA permissible exposure limit
The OSHA PEL for noise is 90 dBA as an 8-hour time-weighted average; engineering or administrative controls are required before relying on hearing protectors.
Hearing conservation program elements
Required elements include noise monitoring, audiometric testing, hearing protection, employee training, and recordkeeping; these components must be provided when exposures reach or exceed the action level.
Baseline audiogram deadline
A baseline audiogram must be obtained within six months of an employee's first exposure at or above 85 dBA, unless a mobile test van allows an extension under OSHA rules.
Noise dosimeter
A noise dosimeter is a wearable instrument that measures an individual's accumulated noise dose and time-weighted average over a work shift.
Five-decibel exchange rate
Under the OSHA 5 dB exchange rate, a 5 dBA increase doubles noise dose and halves the allowable exposure time; 90 dBA is allowed for eight hours.
OSHA TWA formula
For an eight-hour dose, OSHA calculates TWA as 16.61 times the base-10 logarithm of dose divided by 100, plus 90 dBA.
Sound level meter
A sound level meter measures sound pressure level at a location; it is used for area surveys but does not directly measure a worker's personal noise dose.
Cochlear hair cells
Cochlear hair cells are sensory cells in the inner ear that convert sound vibrations into nerve signals; noise damage to these cells is permanent.
Noise notch
A noise-induced hearing loss pattern often shows a notch at 3000 to 6000 Hz, commonly near 4000 Hz, with relative preservation of lower frequencies.
Sensorineural hearing loss
Sensorineural hearing loss results from damage to the cochlea or auditory nerve; most noise-induced hearing loss is sensorineural and irreversible.
Temporary threshold shift
A temporary threshold shift is a reversible hearing loss after noise exposure; repeated temporary shifts can lead to permanent threshold shift over time.
Audiometric test frequencies
OSHA audiograms test air-conduction thresholds at 500, 1000, 2000, 3000, 4000, and 6000 Hz in each ear.
Audiometric booth requirement
Audiometric testing must occur in a test environment whose background noise does not invalidate thresholds; OSHA Appendix D lists maximum permissible octave-band sound levels.
Pure-tone threshold
A pure-tone threshold is the lowest hearing level at which a listener responds to a tone at least 50 percent of the time during ascending presentations.
Annual audiogram
An annual audiogram is required for employees exposed at or above 85 dBA and is compared with the baseline to detect a standard threshold shift.
Daily biological check
Before daily audiometric testing, a person with stable hearing is tested to confirm that the audiometer and earphones produce expected thresholds.
Annual audiometer calibration
Audiometers must receive acoustic calibration at least annually to ANSI standards, verifying frequency, output level, attenuator linearity, and distortion.
Audiometer listening check
A listening check verifies that audiometer output is free of distortion, unwanted noise, or intermittent sound before testing employees.
Earphone cushion inspection
Inspect earphone cushions and headbands for cracks, hardening, or poor tension because defects can change attenuation and invalidate audiometric thresholds.
Standard threshold shift
An OSHA standard threshold shift is an average hearing loss of 10 dB or more at 2000, 3000, and 4000 Hz in either ear.
STS retest interval
When a standard threshold shift is found, the employer should retest within 30 days; if confirmed, the baseline may be revised and the shift recorded.
Recordable hearing loss
A standard threshold shift is recordable on the OSHA 300 log when the average hearing level at 2000, 3000, and 4000 Hz is 25 dB or more.
Baseline revision
A confirmed standard threshold shift may become the new baseline; if the retest does not confirm the shift, the original baseline remains in effect.
Noise reduction rating
The noise reduction rating is a single-number laboratory estimate of hearing protector attenuation; actual workplace protection is often lower.
OSHA NRR formula
For A-weighted exposure, OSHA estimates protected exposure as TWA minus the quantity NRR minus 7; for C-weighted exposure, subtract NRR directly.
Personal attenuation rating
A personal attenuation rating is a fit-test result showing attenuation for an individual worker with a specific protector and fit.
Foam earplug insertion
Roll the foam plug into a narrow cylinder, pull the pinna back, insert deeply, and hold until expansion to obtain a proper seal.
Annual hearing training
Employees in a hearing conservation program must receive annual training on noise effects, audiometric testing, hearing protector selection, fitting, use, and care.
Audiometric record retention
OSHA requires audiometric test records to be retained for the duration of employment plus 30 years, and noise exposure records for two years.
Noise exposure record retention
Noise exposure measurements must be retained for two years and made available to affected employees or their representatives.
Program evaluation metrics
Evaluate a hearing conservation program using standard threshold shift rates, dosimetry results, hearing protector use, training completion, and calibration records.