Registered Environmental Protection Engineer study materials
Registered Environmental Protection Engineer study resources

Registered Environmental Protection Engineer: Solid Waste and Hazardous Waste Management

Registered Environmental Protection Engineer · Work through your exam, one topic at a time.

All guide sections

Solid Waste and Hazardous Waste Management

What this domain tests

Classification, storage and transfer compliance, and the incineration and landfill standards where a single number decides the answer.

Classification chain

  1. Is it 生活垃圾, 一般工业固体废物, or 危险废物?
  2. A waste listed in 国家危险废物名录 (2021 version, 46 broad categories with HW codes) is hazardous without testing. Non-listed wastes are tested against GB 5085.1 to 5085.7: corrosivity (pH at or below 2, or at or above 12.5), acute toxicity, leaching toxicity, total toxic content, reactivity, flammability, infectivity.
  3. The 危险废物豁免管理清单 exempts only the named activity (for example a specific transport or utilisation step), never the whole lifecycle.

Compliance rules under 固废法 (2020)

减量化, 资源化, 无害化 in that priority; the generator bears responsibility; hazardous waste transfer requires the manifest system (转移联单) and a licensed recipient; storage is capped at one year unless an extension is approved; cross-province transfer needs approval.

Disposal standards

  • GB 18484 hazardous waste incineration: combustion gas at or above 1,100 C with at least 2 s residence, destruction and removal efficiency at or above 99.99 percent, slag ignition loss below 5 percent.
  • GB 18485 municipal solid waste incineration: 850 C and 2 s; fly ash is managed as hazardous waste, HW18, even though the feed was ordinary refuse.
  • GB 16889 landfill: entry criteria including moisture, and leachate treatment; GB 18598 for hazardous waste landfill.

Worked example

A hazardous waste incinerator produces 600 kg of slag per day. After ignition at 600 C the residue weighs 570 kg. Ignition loss = (600 − 570)/600 = 5.0 percent.

  • The standard requires below 5 percent, so 5.0 percent fails. The margin is zero, not passing.
  • Control action: check feed mixing, excess air, and residence time; excessive moisture or short residence raises unburnt carbon in slag.
  • Note the parallel test: if a non-listed electroplating sludge leaches hexavalent chromium at 8 mg/L against a GB 5085.3 limit of 5 mg/L, it is hazardous by characteristic regardless of the list.

Traps

  • Testing a listed waste to argue it is not hazardous; listing alone decides.
  • Treating the exemption list as a full exemption.
  • Treating incinerator fly ash as ordinary waste.
  • Reading 热灼减率 as at most 5 percent rather than below 5 percent.
  • Missing the one-year storage cap and the manifest requirement.