CNMT study materials
CNMT study resources

CNMT cheat sheet

CNMT · Keep the key ideas within reach.

Quick reference

General Nuclear Medicine

  • Effective half-life: 1/Te = 1/Tp + 1/Tb; Te is always shorter than either physical or biologic half-life.

  • Tc-99m decays by isomeric transition with a 6.02-hour physical half-life and 140 keV gamma emission.

  • Mo-99/Tc-99m generator: elute with 0.9% saline; Mo-99 breakthrough limit is 0.15 kBq Mo-99 per MBq Tc-99m (0.15 µCi/mCi).

  • Alumina column breakthrough limit for Al+3 in eluate is 10 µg/mL.

  • Radiopharmaceutical dose is adjusted by body weight for children per North American consensus guidelines; adult reference activities scale by weight fraction.

  • Tc-99m MDP localizes to bone via chemisorption to hydroxyapatite; kidney and bladder activity is normal.

  • MAA particles are trapped in pulmonary capillaries by precapillary blockade; typical adult dose 2-4 mCi with 200,000-700,000 particles.

  • Free pertechnetate is identified on scan by thyroid, salivary gland, and stomach uptake; reducing agent failure is a common cause.

  • Tc-99m sulfur colloid is cleared by the reticuloendothelial system; used for liver/spleen and marrow imaging.

Quick reference

Computed Tomography (NMTCB(CT), post-primary)

  • CT number (Hounsfield unit) = 1000 × (µtissue − µwater) / µwater; water = 0 HU, air ≈ −1000 HU.

  • Window width controls contrast (displayed gray range); window level controls brightness (center HU).

  • Pitch = table travel per gantry rotation / beam collimation width; pitch >1 reduces dose and increases noise.

  • CTDIvol estimates dose per slice; DLP = CTDIvol × scan length; effective dose ≈ DLP × k-factor.

  • ALARA dose reduction tools: automatic exposure control (mA modulation), iterative reconstruction, tube voltage lowering.

  • Beam hardening appears as cupping or dark streaks between dense structures; corrected by filtration and beam-hardening algorithms.

  • Spatial resolution is improved by small focal spot, thin slices, and small field of view (matrix size / FOV = pixel size).

  • Contrast-induced nephropathy risk is reduced by hydration and minimizing volume; metformin may require holding per protocol.

  • CTDI100 is measured in a 100-mm pencil ionization chamber in standard 16-cm (head) or 32-cm (body) phantoms.

Quick reference

Nuclear Cardiology Technology (NCT)

  • Tc-99m sestamibi and tetrofosmin are lipophilic cations taken up by mitochondria; myocardial uptake proportional to perfusion.

  • Rest/stress protocol: stress dose typically 8-12 mCi Tc-99m; rest dose 8-12 mCi, or same-day rest-then-stress with lower rest activity.

  • Adenosine, regadenoson, and dipyridamole cause coronary vasodilation via A2A receptors; contraindicated with severe asthma or high-grade AV block.

  • Caffeine and methylxanthines must be withheld before regadenoson/dipyridamole stress (typically ≥12 hours for caffeine).

  • Dipyridamole/regadenoson effects are reversed with aminophylline; adenosine infusion is stopped for severe symptoms.

  • Treadmill Bruce protocol endpoint: ≥85% of age-predicted maximum heart rate (220 − age) or symptom-limited.

  • Gated SPECT: 8 or 16 frames per R-R interval; arrhythmia causes beat rejection and requires rhythm monitoring.

  • Tc-99m sestamibi hepatobiliary clearance can cause subdiaphragmatic activity; a fatty meal or delay reduces artifact.

  • Thallium-201 has 73 keV mercury X-rays and redistributes; Tc-99m agents do not redistribute significantly.

Quick reference

Positron Emission Tomography (PET)

  • F-18 has a 109.8-minute half-life and emits a positron; annihilation produces two 511 keV photons at ~180°.

  • FDG patient preparation: fast ≥4-6 hours, glucose ideally <200 mg/dL (or per protocol), and no vigorous exercise 24 hours prior.

  • FDG uptake time is typically 60 minutes; uptake is high in brain, myocardium (variable), kidneys, bladder, and tumor.

  • Standardized uptake value (SUV) = activity concentration / (injected dose / body weight); SUVmax is the common metric.

  • Coincidence detection uses a timing window (typically ~4-6 ns); random coincidences increase with count rate.

  • Time-of-flight PET improves signal-to-noise by localizing annihilation along the line of response.

  • Attenuation correction uses CT (or transmission) data; misregistration between PET and CT causes artifacts.

  • F-18 NaF bone PET localizes to osteoblastic activity; normal uptake in skeleton and kidneys/bladder.

  • Rb-82 has a 76-second half-life and is generator-produced; requires a strontium-82/rubidium-82 generator.

Quick reference

Nuclear Medicine Advance Associate (NMAA)

  • Scope of NMAA practice is defined by state law and institutional policy; tasks are performed under direct supervision of a licensed technologist or physician.

  • Standard precautions apply to all patients; hand hygiene is the primary infection-control measure.

  • Radiopharmaceutical identification requires checking the label: radionuclide, activity, calibration time, and patient name.

  • Dose assay uses a dose calibrator; constancy, geometry, and linearity checks are performed per protocol.

  • Patient identification uses two identifiers (name and date of birth) before any dose administration or imaging.

  • Pregnancy and breastfeeding screening must be documented before radiopharmaceutical administration.

  • Sharps and radioactive waste are segregated; contaminated items are held for decay per institutional policy.

  • Vital signs and IV access are monitored and documented; extravasation is reported to the supervising technologist.

Quick reference

General Nuclear Medicine

  • Geiger-Mueller counters detect radiation but cannot measure energy; used for contamination surveys.

  • Well counter and dose calibrator use ionization chambers; daily constancy check with a long-lived source (e.g., Cs-137).

  • Octreotide (In-111 pentetreotide) binds somatostatin receptors; normal uptake in liver, spleen, kidneys, and pituitary.

  • I-131 therapy for hyperthyroidism uses beta emission for tissue destruction; patient release criteria depend on dose rate.

  • Sentinel node imaging uses filtered Tc-99m sulfur colloid or tilmanocept; injection site and node are imaged.

  • Renal scan with Tc-99m MAG3 or DTPA: MAG3 is secreted by tubules; DTPA is filtered by glomeruli.

  • Gastric emptying study uses a standardized solid meal labeled with Tc-99m sulfur colloid; images at intervals over 90-120 minutes.

  • Meckel diverticulum scan uses Tc-99m pertechnetate; ectopic gastric mucosa concentrates pertechnetate.

Quick reference

Computed Tomography (NMTCB(CT), post-primary)

  • Reconstruction kernel choice trades resolution for noise: sharp/bone kernels for bone, soft kernels for soft tissue.

  • Helical scanning with pitch >1 increases table speed and reduces dose but may increase partial-volume artifact.

  • kVp affects both dose and contrast; low kVp increases iodine contrast for a given mAs.

  • CT number depends on effective beam energy; the same tissue may differ between scanners or kVp settings.

  • Reformatting to coronal/sagittal planes requires thin axial slices and isotropic voxels.

  • Metal artifact reduction uses iterative algorithms and tube voltage adjustment; severe metal causes streak artifacts.

  • Radiation dose units: 1 Gy = 1 J/kg; 1 Sv = 1 Gy × radiation weighting factor (1 for X-rays).

  • Patient shielding and collimation reduce dose to radiosensitive organs such as thyroid and breast.

Quick reference

Nuclear Cardiology Technology (NCT)

  • Patient positioning: left arm raised over head to reduce breast and arm attenuation artifact.

  • Breast attenuation causes fixed anterior defect; prone imaging or attenuation correction reduces false positives.

  • Diaphragmatic attenuation causes fixed inferior wall defect; prone imaging or attenuation correction is used.

  • ECG gating requires a regular rhythm; R-wave triggering rejects ectopic beats.

  • Left ventricular ejection fraction from gated SPECT is calculated from end-diastolic and end-systolic volumes.

  • Stress-only protocols reduce dose; normal stress images may avoid rest imaging.

  • Nitroglycerin may be given before stress per protocol to improve coronary vasodilation.

  • Tc-99m sestamibi injection during peak stress captures perfusion at the moment of injection; imaging occurs later.

Quick reference

Positron Emission Tomography (PET)

  • FDG is a glucose analog trapped after phosphorylation by hexokinase; it does not undergo further glycolysis.

  • Brown adipose tissue uptake is symmetric, supraclavicular, and cold-related; warming and beta-blockade reduce it.

  • Muscular uptake from recent exercise or insulin can mimic disease; rest and fasting reduce this.

  • PET/CT acquisition: CT for attenuation correction and localization, then PET emission over multiple bed positions.

  • Randoms and scatter are corrected; dead-time losses increase with high activity.

  • SUV is affected by body composition, uptake time, and plasma glucose; serial comparisons require consistent technique.

  • F-18 FDG is excreted renally; hydration and voiding reduce bladder dose.

  • PET spatial resolution is limited by positron range and detector size; typical resolution ~4-5 mm.

Quick reference

Nuclear Medicine Advance Associate (NMAA)

  • Dose administration records include radiopharmaceutical, activity, route, time, and lot number.

  • Patient education includes hydration, voiding, and radiation safety instructions after administration.

  • Emergency equipment and supplies are checked per institutional schedule.

  • Radiopharmaceutical storage requires lead shielding and locked, labeled areas.

  • Spills are contained, reported, and surveyed; decontamination follows institutional radiation safety policy.

  • IV catheter patency is confirmed before injection; infiltration is documented and reported.

  • Patient transport and positioning are performed with attention to lines, drains, and radiation exposure.

  • Quality control records are maintained for dose calibrators and imaging equipment per protocol.

Quick reference

General Nuclear Medicine

  • Radioactive decay follows N = N0 e^(−λt); λ = 0.693 / T½.

  • Activity remaining after n half-lives = A0 × (1/2)^n.

  • The 10 half-life rule: after 10 half-lives, activity is <0.1% of original.

  • Gamma camera energy resolution is typically 10-12% FWHM at 140 keV for Tc-99m.

  • Photopeak window for Tc-99m is centered at 140 keV with a ±10-20% window.

  • Collimator choice: low-energy high-resolution for Tc-99m; medium-energy for In-111 and I-131; high-energy for I-131 therapy imaging.

  • Uniformity and linearity floods are performed daily; resolution and sensitivity are tested per protocol.

  • Dead time and pulse pileup increase with high activity; count-rate performance is tested.

Quick reference

Computed Tomography (NMTCB(CT), post-primary)

  • Matrix size and FOV determine pixel size: pixel = FOV / matrix.

  • Slice thickness affects partial-volume averaging; thin slices improve z-axis resolution.

  • Detector row count determines maximum simultaneous slices; cone-beam geometry affects coverage.

  • Tube current (mA) and exposure time (mAs) are primary dose drivers; mA modulation varies with patient attenuation.

  • CT fluoroscopy and interventional modes use low-dose settings; operator dose is reduced by distance and shielding.

  • Quality control includes daily air calibration, water phantom CT number, noise, and uniformity checks.

  • Artifacts: motion (streaks), ring (detector calibration), and out-of-field (patient truncation) artifacts.

  • Contrast timing uses bolus tracking or test bolus; scan delay is chosen based on circulation time.

Quick reference

Nuclear Cardiology Technology (NCT)

  • Tc-99m tetrofosmin has rapid clearance from blood and liver; imaging can begin ~15-30 minutes after injection.

  • Tc-99m sestamibi has slower hepatobiliary clearance; imaging typically begins 45-60 minutes after injection.

  • Rest-stress same-day order affects residual activity; the higher-dose study is usually performed second.

  • Treadmill stress uses Bruce protocol with 3-minute stages; heart rate, blood pressure, and ECG are monitored.

  • Exercise stress is preferred when the patient can achieve adequate workload; pharmacologic stress is used otherwise.

  • Attenuation correction with CT or line sources improves specificity; misregistration can create artifacts.

  • Gated SPECT functional parameters include EDV, ESV, and EF; normal EF is generally ≥50%.

  • Patient motion during acquisition causes blurring and artifacts; motion correction or repeat acquisition is used.

Quick reference

Positron Emission Tomography (PET)

  • F-18 FDG dose is typically 5-15 mCi for adults; pediatric dosing is weight-based.

  • Injected dose measurement requires a dose calibrator; residual activity in syringe and tubing is accounted for.

  • PET/CT patient positioning: arms up for body imaging to reduce attenuation and truncation artifacts.

  • Respiratory motion degrades PET/CT registration; respiratory gating or coaching reduces motion.

  • SUV normalization uses lean body mass or body surface area in some protocols; report the method used.

  • Standard uptake time is 60 minutes; deviations affect SUV and should be documented.

  • PET detector crystals (e.g., LSO, LYSO, BGO) differ in light output, decay time, and stopping power.

  • Block detectors and photomultiplier tubes convert scintillation light into electronic signals.

Quick reference

Nuclear Medicine Advance Associate (NMAA)

  • Radiation safety: time, distance, and shielding reduce occupational dose.

  • Personal dosimeters are worn at collar level and exchanged per institutional schedule.

  • Pregnant workers should declare pregnancy to allow dose monitoring per policy.

  • Patient confidentiality and HIPAA apply to all imaging records and communications.

  • Informed consent and patient rights are documented before procedures when required.

  • Infection control includes standard precautions and transmission-based precautions as indicated.

  • Emergency response includes knowing the location of spill kits, eyewash stations, and emergency contacts.

  • Continuing education and competency documentation are required to maintain role qualifications.

Quick reference

General Nuclear Medicine

  • Bone scan: 2-4 hour delay after Tc-99m MDP allows skeletal uptake and renal clearance; hydration and voiding are encouraged.

  • Three-phase bone scan: flow, blood pool, and delayed phases; used to distinguish cellulitis from osteomyelitis.

  • Thyroid uptake and scan use I-123 or Tc-99m pertechnetate; normal 24-hour I-123 uptake is roughly 10-30%.

  • Parathyroid imaging uses Tc-99m sestamibi with delayed imaging; abnormal parathyroid retains tracer.

  • Lymphoscintigraphy uses Tc-99m filtered sulfur colloid; images are obtained immediately and delayed.

  • V/Q scan uses Tc-99m DTPA aerosol or Technegas for ventilation and Tc-99m MAA for perfusion.

  • HIDA scan uses Tc-99m mebrofenin or disofenin; gallbladder visualization within 60 minutes is normal.

  • GI bleed scan uses Tc-99m labeled red blood cells; positive study shows intraluminal activity that moves.

Quick reference

Computed Tomography (NMTCB(CT), post-primary)

  • CT dose index (CTDI) is measured in phantoms; CTDIvol accounts for pitch.

  • Size-specific dose estimate (SSDE) adjusts CTDIvol for patient size.

  • Effective dose for a typical chest CT is roughly 5-10 mSv; abdomen/pelvis is higher.

  • Diagnostic reference levels guide dose optimization; institutions compare against national benchmarks.

  • Iterative reconstruction reduces noise at lower dose compared with filtered back projection.

  • Organ-based tube current modulation reduces dose to anterior structures such as breast and thyroid.

  • Automatic tube potential selection chooses kVp based on patient size and contrast needs.

  • Pediatric CT requires size-adjusted protocols to reduce dose.

Quick reference

Nuclear Cardiology Technology (NCT)

  • Myocardial perfusion imaging detects ischemia as a reversible defect and infarction as a fixed defect.

  • Reversible defect = decreased uptake on stress with normal rest uptake.

  • Fixed defect = decreased uptake on both stress and rest; may represent scar or attenuation.

  • Reverse redistribution can occur with some agents and is interpreted cautiously.

  • Tracer uptake is proportional to regional blood flow at the time of injection.

  • Stress ECG changes and symptoms are documented and correlated with perfusion findings.

  • Beta-blockers and calcium channel blockers may be withheld before exercise stress per protocol.

  • Patient preparation includes fasting and avoiding caffeine before pharmacologic stress.

Quick reference

Positron Emission Tomography (PET)

  • FDG PET is used in oncology for staging, restaging, and treatment response assessment.

  • Brain FDG PET shows high cortical uptake; decreased uptake patterns help evaluate dementia.

  • Myocardial FDG uptake is variable; viability protocols use glucose loading and insulin.

  • Infection and inflammation show FDG uptake; this can mimic malignancy.

  • PET/CT reporting includes SUVmax, lesion location, size, and comparison with prior studies.

  • Artifacts: misregistration, truncation, and metallic implants can affect interpretation.

  • Radiotracer half-life determines delivery logistics; F-18 allows transport within a few hours.

  • Generator-produced Rb-82 requires a generator with a defined shelf life and elution schedule.

Quick reference

Nuclear Medicine Advance Associate (NMAA)

  • Dose calibrator geometric and linearity checks ensure accurate activity measurement across ranges.

  • Radiopharmaceutical labels include calibration time and expiration; expired doses are not administered.

  • Patient monitoring includes observation for adverse reactions and extravasation.

  • Documentation of patient history, allergies, and medications supports safe care.

  • Radiation warning signs and labels are posted in restricted areas.

  • Waste decay-in-storage records are maintained until background levels are reached.

  • Communication with the supervising technologist is required for any deviation from protocol.

  • Equipment cleaning and disinfection follow institutional policies.

Quick reference

General Nuclear Medicine

  • Tc-99m DTPA is used for renal imaging and glomerular filtration measurement; it is filtered by glomeruli.

  • Tc-99m DMSA binds renal cortex; used for cortical scarring evaluation.

  • Tc-99m MAA lung perfusion is contraindicated in right-to-left shunt and pulmonary hypertension per labeling.

  • I-123 is preferred over I-131 for thyroid imaging due to lower dose and better image quality.

  • Tc-99m pertechnetate is used for thyroid, salivary, and Meckel imaging.

  • Radiation safety: lead shielding reduces exposure; inverse square law applies to distance.

  • Decay correction adjusts activity to a reference time using the half-life formula.

  • Dose calibrator accuracy is verified with a certified source.

Quick reference

Computed Tomography (NMTCB(CT), post-primary)

  • MPR and 3D reconstructions require thin-slice acquisition and adequate overlap.

  • Windowing presets: bone (wide width, high level), soft tissue (narrower width, lower level), lung (wide width, low level).

  • CT number calibration uses water and air phantoms; drift indicates need for service.

  • Noise is reduced by higher mAs, thicker slices, and iterative reconstruction.

  • Spatial resolution is limited by focal spot size, detector size, and reconstruction kernel.

  • Pitch <1 increases dose and overlap; pitch >1 reduces dose and may increase noise.

  • Patient centering affects dose and image quality; isocenter positioning is important.

  • Contrast media osmolality and viscosity affect injection rate and patient comfort.

Quick reference

Nuclear Cardiology Technology (NCT)

  • Radiotracer injection during stress should be followed by a flush to ensure full dose delivery.

  • Imaging delays depend on tracer kinetics; sestamibi and tetrofosmin have different clearance profiles.

  • Attenuation correction maps must be registered with emission data; misregistration causes artifacts.

  • Gated SPECT acquisition uses multiple projections over 180° or 360° depending on protocol.

  • Reconstruction uses filtered back projection or iterative methods; iterative reduces noise.

  • Normal databases are used for quantitative perfusion scoring.

  • Patient coaching reduces motion and improves image quality.

  • Stress test monitoring includes ECG, vital signs, and symptom assessment.

Quick reference

Positron Emission Tomography (PET)

  • PET/CT acquisition includes a CT scout, CT acquisition, and PET emission scan.

  • CT is used for attenuation correction and anatomic localization.

  • PET image reconstruction includes attenuation, scatter, randoms, and dead-time corrections.

  • SUVmax is sensitive to noise and small lesions; SUVmean and peak SUV are alternatives.

  • Dual-time-point imaging can help distinguish malignant from inflammatory uptake.

  • Patient preparation instructions must be clear and documented.

  • Radiation exposure to staff is reduced by distance, shielding, and efficient workflow.

  • Quality control includes daily detector checks and normalization.

Quick reference

Nuclear Medicine Advance Associate (NMAA)

  • Assistive tasks are performed within the scope defined by state law and institutional policy.

  • Direct supervision means the supervising technologist or physician is available and overseeing the task.

  • Patient identification uses two identifiers before any procedure.

  • Allergies and prior reactions are documented before contrast or radiopharmaceutical administration.

  • Vital signs are recorded before, during, and after procedures as indicated.

  • IV access care includes site assessment and documentation.

  • Radiation safety instructions are provided to patients and caregivers.

  • Incident reports are completed for spills, extravasation, and adverse events.

Quick reference

General Nuclear Medicine

  • Radionuclide purity is the fraction of activity from the desired radionuclide; tested with gamma spectroscopy or decay.

  • Radiochemical purity is the fraction of activity in the desired chemical form; tested with chromatography.

  • Mo-99 breakthrough is tested after each elution and at generator receipt.

  • Aluminum breakthrough is tested with a colorimetric method.

  • Dose calibrator constancy is checked daily with a long-lived source.

  • Dose calibrator linearity is checked across the activity range used clinically.

  • Dose calibrator geometry is checked with sources in different volumes and positions.

  • Records of QC are retained per regulatory requirements.

Quick reference

Computed Tomography (NMTCB(CT), post-primary)

  • CTDIvol and DLP are displayed on the scanner console and recorded in dose reports.

  • Dose-length product (DLP) = CTDIvol × scan length.

  • Effective dose = DLP × conversion factor (k-factor) for the body region.

  • Patient size affects dose; SSDE adjusts for diameter.

  • Automatic exposure control modulates mA based on attenuation.

  • Iterative reconstruction reduces noise and allows lower dose.

  • Organ-based modulation reduces dose to anterior organs.

  • Pediatric protocols use lower kVp and mAs.

Quick reference

Nuclear Cardiology Technology (NCT)

  • Myocardial perfusion imaging uses stress and rest images to assess ischemia and scar.

  • Reversible defects suggest ischemia; fixed defects suggest scar or attenuation.

  • Attenuation artifacts are common in the inferior wall and anterior wall.

  • Prone imaging and attenuation correction reduce artifacts.

  • Gated SPECT provides functional data including EF and wall motion.

  • Stress testing requires monitoring and documentation.

  • Pharmacologic stress agents have specific contraindications and reversal agents.

  • Patient preparation and instructions are essential for accurate imaging.

Quick reference

Positron Emission Tomography (PET)

  • FDG is a glucose analog that is trapped in cells after phosphorylation.

  • FDG uptake is high in brain, kidneys, bladder, and some tumors.

  • Patient preparation includes fasting and avoiding exercise.

  • SUV is a semiquantitative measure of uptake.

  • PET/CT combines functional and anatomic imaging.

  • Attenuation correction is required for quantitative PET.

  • Artifacts can arise from motion, misregistration, and metal.

  • Radiation safety and dose optimization are important in PET.

Quick reference

Nuclear Medicine Advance Associate (NMAA)

  • The NMAA performs tasks under supervision within scope of practice.

  • Patient identification and safety checks are required before procedures.

  • Radiation safety principles include time, distance, and shielding.

  • Infection control and standard precautions apply to all patients.

  • Documentation of procedures and patient information is required.

  • Emergency procedures and contacts should be known.

  • Continuing education and competency are required.

  • Communication with the supervising technologist is essential.

Quick reference

General Nuclear Medicine

  • The gamma camera uses a collimator, scintillation crystal, photomultiplier tubes, and electronics.

  • The photopeak window is centered on the gamma energy of interest.

  • Energy resolution is the ability to distinguish energies; it is measured as FWHM.

  • Uniformity and linearity are tested with flood images.

  • Sensitivity is the count rate per unit activity.

  • Resolution is the ability to distinguish small structures.

  • Dead time and count-rate performance are tested.

  • Quality control records are maintained.

Quick reference

Computed Tomography (NMTCB(CT), post-primary)

  • CT numbers are expressed in Hounsfield units.

  • Water is 0 HU and air is approximately −1000 HU.

  • Window width and level control display contrast and brightness.

  • Pitch affects dose and image noise.

  • CTDIvol and DLP are dose metrics.

  • Iterative reconstruction reduces noise.

  • Patient centering affects dose.

  • Pediatric protocols reduce dose.

Quick reference

Nuclear Cardiology Technology (NCT)

  • Tc-99m sestamibi and tetrofosmin are perfusion tracers.

  • Uptake is proportional to blood flow at injection.

  • Stress and rest images are compared.

  • Reversible defects indicate ischemia.

  • Fixed defects indicate scar or attenuation.

  • Gated SPECT provides EF and wall motion.

  • Attenuation correction improves specificity.

  • Patient preparation affects image quality.

Quick reference

Positron Emission Tomography (PET)

  • F-18 has a 110-minute half-life.

  • Annihilation produces two 511 keV photons.

  • Coincidence detection identifies annihilation events.

  • Attenuation correction is required for quantification.

  • SUV is a semiquantitative measure.

  • Patient preparation affects FDG uptake.

  • Artifacts include motion and misregistration.

  • Radiation safety is important.

Quick reference

Nuclear Medicine Advance Associate (NMAA)

  • Scope of practice is defined by state law and institutional policy.

  • Supervision is required for tasks performed by the NMAA.

  • Patient identification uses two identifiers.

  • Radiation safety principles apply.

  • Infection control applies.

  • Documentation is required.

  • Emergency procedures should be known.

  • Continuing education is required.