CNMT study materials
CNMT study resources

CNMT flashcards

CNMT · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Effective half-life formula
1/Te = 1/Tp + 1/Tb, where Tp is physical half-life and Tb is biologic half-life. The effective half-life is always shorter than either component.
Tc-99m physical half-life
Tc-99m decays by isomeric transition with a 6.02-hour physical half-life and emits a 140 keV gamma ray used for imaging.
Mo-99 breakthrough limit
The allowable Mo-99 concentration in Tc-99m eluate is 0.15 kBq Mo-99 per MBq Tc-99m (0.15 µCi/mCi), tested after each elution.
Aluminum breakthrough limit
Aluminum ion concentration in generator eluate must not exceed 10 µg/mL, tested by a colorimetric method.
Hounsfield unit formula
CT number = 1000 × (µtissue − µwater) / µwater. Water is 0 HU and air is approximately −1000 HU.
Window width and level
Window width sets the range of CT numbers displayed as gray, controlling contrast. Window level sets the center value, controlling brightness.
CT pitch definition
Pitch equals table travel per gantry rotation divided by beam collimation width. Pitch greater than 1 reduces dose and increases image noise.
DLP and effective dose
Dose-length product equals CTDIvol multiplied by scan length. Effective dose is estimated by multiplying DLP by a body-region conversion factor.
CTDIvol meaning
CTDIvol is the volume computed tomography dose index, a standardized dose metric measured in phantoms that accounts for pitch.
Tc-99m sestamibi uptake
Sestamibi is a lipophilic cation taken up by myocardial mitochondria in proportion to regional blood flow at the time of injection.
Regadenoson contraindication
Regadenoson is a vasodilator that should not be given to patients with severe asthma or high-grade atrioventricular block.
Caffeine before vasodilator stress
Caffeine and methylxanthines block adenosine receptors and must be withheld before regadenoson or dipyridamole stress, typically for at least 12 hours.
Reversible perfusion defect
A reversible defect shows decreased tracer uptake on stress images with normal or near-normal uptake on rest images, indicating ischemia.
Fixed perfusion defect
A fixed defect shows decreased uptake on both stress and rest images, suggesting scar or attenuation artifact rather than ischemia.
Gated SPECT ejection fraction
Gated SPECT calculates ejection fraction from end-diastolic and end-systolic volumes derived from ECG-gated frames across the cardiac cycle.
Aminophylline reversal
Aminophylline is used to reverse the effects of dipyridamole or regadenoson when severe symptoms occur during pharmacologic stress testing.
F-18 physical half-life
F-18 has a 109.8-minute physical half-life and decays by positron emission, producing annihilation photons for PET imaging.
Annihilation photon energy
Positron-electron annihilation produces two 511 keV photons emitted approximately 180 degrees apart, which are detected in coincidence.
SUV formula
Standardized uptake value equals activity concentration divided by injected dose divided by body weight. SUVmax is the most commonly reported metric.
FDG patient preparation
Patients fast for at least 4-6 hours before FDG PET, with glucose ideally below 200 mg/dL, and avoid vigorous exercise for 24 hours.
FDG uptake time
FDG PET imaging is typically performed about 60 minutes after injection, allowing uptake in tissues and clearance from blood.
Brown fat FDG uptake
Brown adipose tissue shows symmetric supraclavicular and neck uptake that is cold-related; warming and beta-blockade reduce this uptake.
Time-of-flight PET
Time-of-flight PET measures small differences in photon arrival times to localize annihilation events along the line of response, improving signal-to-noise.
Rb-82 half-life
Rubidium-82 has a 76-second half-life and is produced by a strontium-82/rubidium-82 generator for myocardial perfusion PET.
NMAA scope of practice
The nuclear medicine advance associate performs tasks within the scope defined by state law and institutional policy under supervision of a licensed technologist or physician.
Two patient identifiers
Before any dose administration or imaging procedure, staff verify two identifiers such as name and date of birth to confirm patient identity.
Time distance shielding
Radiation dose to staff is reduced by minimizing time near sources, maximizing distance, and using appropriate lead shielding.
Dose calibrator constancy check
A daily constancy check verifies dose calibrator response using a long-lived source such as Cs-137, confirming stable measurement over time.
Pregnancy screening
Pregnancy and breastfeeding status are documented before radiopharmaceutical administration to assess risk and adjust the procedure.
Extravasation reporting
Extravasation of a radiopharmaceutical is documented and reported to the supervising technologist, with the site assessed and monitored.
Radiopharmaceutical label check
Before administration, staff verify the radiopharmaceutical label for radionuclide, activity, calibration time, and patient name.
Decay formula
Activity remaining equals initial activity multiplied by e raised to the negative decay constant times time, where decay constant equals 0.693 divided by half-life.