radionuclide generator

A system that produces a short-lived radioactive daughter from a longer-lived parent, allowing on-site elution of a usable isotope such as technetium-99m from a molybdenum-99 column.

Related: elution efficiency, transient equilibrium
transient equilibrium

A condition in which a daughter radionuclide grows to a maximum activity slightly greater than its parent and thereafter decays at the parent's rate, typical of a molybdenum-99/technetium-99m generator.

Related: radionuclide generator, elution efficiency
elution efficiency

The percentage of available daughter activity actually removed from a generator column during elution, calculated by dividing the activity eluted by the activity expected on the column.

Related: radionuclide generator, breakthrough
breakthrough

Unwanted leakage of the parent radionuclide or column material into the eluate; molybdenum-99 breakthrough must stay below regulatory limits before patient use.

Related: elution efficiency, radionuclide purity
radionuclide purity

The fraction of total radioactivity in a preparation that comes from the intended radionuclide, excluding contaminating isotopes that could add unnecessary dose to the patient.

Related: breakthrough, radiochemical purity
radiochemical purity

The proportion of the total radioactivity present in the desired chemical form, such as free pertechnetate versus bound tracer, measured by methods like chromatography.

Related: radionuclide purity, free pertechnetate
free pertechnetate

Unbound technetium-99m that has not attached to the labeling agent; it accumulates in thyroid, stomach, and salivary tissue and degrades image quality when present in excess.

Related: radiochemical purity, tagging efficiency
tagging efficiency

The percentage of radioactivity successfully bound to the radiopharmaceutical molecule during preparation, a practical measure of how much usable tracer is available for injection.

Related: radiochemical purity, free pertechnetate
half-life

The time required for half of the atoms in a radioactive sample to decay; physical half-life is fixed for each isotope while biologic and effective half-lives describe clearance from the body.

Related: effective half-life, decay correction
effective half-life

The combined result of physical decay and biologic clearance, describing how quickly activity in a patient's body actually falls; it is always shorter than either component half-life.

Related: half-life, decay correction
decay correction

Mathematical adjustment of measured or prescribed activity for radioactive decay between the calibration time and the time of use or imaging.

Related: half-life, dose calibrator
dose calibrator

A well-type ionization chamber used to measure the activity of radiopharmaceutical doses before administration, requiring daily constancy checks and periodic accuracy testing.

Related: decay correction, constancy check
constancy check

A daily quality test confirming that a dose calibrator, gamma camera, or other instrument responds consistently to a known source, detecting drift before it affects patient studies.

Related: dose calibrator, quality control
energy resolution

The ability of a gamma camera or detector to distinguish gamma rays of similar energy, usually expressed as the full width at half maximum of a photopeak.

Related: photopeak, pulse height analyzer
photopeak

The peak in a gamma spectrum produced when a gamma ray deposits its full energy in the detector, used to set the energy window for imaging.

Related: energy resolution, pulse height analyzer
pulse height analyzer

Electronic circuitry that accepts detector signals falling within a chosen energy window and rejects scattered or background events outside that range.

Related: photopeak, scatter
scatter

Gamma photons that change direction and lose energy through Compton interactions in the patient or detector; scatter degrades contrast and is reduced by energy windowing and correction algorithms.

Related: pulse height analyzer, attenuation correction
collimator

A lead device placed in front of the camera crystal with holes that restrict incoming photons to a preferred direction, trading sensitivity for spatial resolution.

Related: spatial resolution, sensitivity
spatial resolution

The smallest separation at which two point sources can still be distinguished in an image, commonly reported as full width at half maximum in millimeters.

Related: collimator, sensitivity
sensitivity

The number of detected counts per unit of activity for a given imaging system and collimator, reflecting how efficiently emitted photons are captured.

Related: collimator, spatial resolution
uniformity

A measure of how evenly a gamma camera images a uniform flood source; poor uniformity produces ring or spot artifacts and is assessed with daily flood images.

Related: quality control, constancy check
quality control

The scheduled testing program that verifies equipment and radiopharmaceutical performance against accepted standards, including daily, weekly, and periodic tests.

Related: uniformity, constancy check
ALARA

The principle of keeping radiation exposure as low as reasonably achievable by using time, distance, and shielding while still obtaining the needed diagnostic information.

Related: shielding, occupational dose
occupational dose

Radiation dose received by a worker during job duties, monitored with a personal dosimeter and compared against annual regulatory limits.

Related: ALARA, personnel dosimeter
personnel dosimeter

A badge or ring worn to record cumulative radiation exposure of an individual worker, typically read periodically by a monitoring service.

Related: occupational dose, ALARA
Hounsfield unit

A scaled CT number expressing tissue attenuation relative to water, where water is zero, air is about minus 1000, and dense bone is strongly positive.

Related: window width and level, attenuation correction
window width and level

Display settings that map a range of CT numbers to visible gray shades; level sets the center and width sets the range, controlling contrast and brightness.

Related: Hounsfield unit, CTDIvol
pitch

In helical CT, the table travel per gantry rotation divided by the beam collimation; higher pitch speeds coverage but can affect image noise and dose.

Related: CTDIvol, dose-length product
CTDIvol

Volume computed tomography dose index, an estimate of the average absorbed dose within the scanned volume for a given protocol, displayed on the scanner console.

Related: dose-length product, pitch
dose-length product

The product of CTDIvol and scan length, used to estimate total radiation output for a CT examination and to compare protocols.

Related: CTDIvol, pitch
attenuation correction

Correction of PET or SPECT images for photon loss as signal passes through body tissue, typically using a CT-derived map so deeper structures are not falsely shown as cold.

Related: Hounsfield unit, scatter
standardized uptake value

A semiquantitative PET metric comparing lesion activity to injected dose and body size, used to help distinguish benign from malignant uptake and to track response.

Related: maximum intensity projection, attenuation correction
maximum intensity projection

A three-dimensional rendering that displays the brightest voxel along each viewing ray, commonly used to survey whole-body PET images quickly.

Related: standardized uptake value, coincidence detection
coincidence detection

The PET principle of recording two annihilation photons detected nearly simultaneously on opposite sides of the detector ring, which defines a line of response.

Related: time of flight, maximum intensity projection
time of flight

A PET capability that measures small arrival-time differences between annihilation photons to localize the event along the line of response, improving signal-to-noise.

Related: coincidence detection, attenuation correction
radiotracer extravasation

Leakage of injected activity into tissue around the vein, which can cause false nodal uptake, alter dosimetry, and require documentation and follow-up.

Related: infiltration, injection site
infiltration

Delivery of a radiopharmaceutical or contrast agent into surrounding tissue rather than the vein, potentially causing local irritation and invalidating uptake measurements.

Related: radiotracer extravasation, injection site
venipuncture

Puncture of a vein to administer a radiopharmaceutical or withdraw blood, requiring proper site selection, aseptic technique, and safe sharps handling.

Related: injection site, infiltration
injection site

The location chosen for administering a radiopharmaceutical; it should be documented and imaged when needed to identify dose infiltration or residual activity.

Related: venipuncture, radiotracer extravasation
myocardial perfusion imaging

Nuclear cardiology study using tracers taken up by heart muscle to assess blood flow at stress and rest, revealing ischemia or scar.

Related: reversible defect, fixed defect
reversible defect

A perfusion abnormality present on stress images but normal on rest images, indicating tissue that is ischemic but still viable.

Related: fixed defect, myocardial perfusion imaging
fixed defect

A perfusion abnormality seen on both stress and rest images, usually representing scar from prior infarction rather than reversible ischemia.

Related: reversible defect, myocardial perfusion imaging
gated SPECT

Acquisition synchronized to the electrocardiogram so images can be binned by cardiac phase, allowing assessment of wall motion and ejection fraction.

Related: myocardial perfusion imaging, ejection fraction
ejection fraction

The percentage of ventricular volume ejected per heartbeat, derived from gated studies or blood pool imaging to evaluate systolic function.

Related: gated SPECT, myocardial perfusion imaging