CNMT key terms
CNMT · Get comfortable with the vocabulary.
- radionuclide generator
- Related: elution efficiency, transient equilibrium
A system that produces a short-lived radioactive daughter from a longer-lived parent, allowing on-site elution of a usable isotope such as technetium-99m from a molybdenum-99 column.
- transient equilibrium
- Related: radionuclide generator, elution efficiency
A condition in which a daughter radionuclide grows to a maximum activity slightly greater than its parent and thereafter decays at the parent's rate, typical of a molybdenum-99/technetium-99m generator.
- elution efficiency
- Related: radionuclide generator, breakthrough
The percentage of available daughter activity actually removed from a generator column during elution, calculated by dividing the activity eluted by the activity expected on the column.
- breakthrough
- Related: elution efficiency, radionuclide purity
Unwanted leakage of the parent radionuclide or column material into the eluate; molybdenum-99 breakthrough must stay below regulatory limits before patient use.
- radionuclide purity
- Related: breakthrough, radiochemical purity
The fraction of total radioactivity in a preparation that comes from the intended radionuclide, excluding contaminating isotopes that could add unnecessary dose to the patient.
- radiochemical purity
- Related: radionuclide purity, free pertechnetate
The proportion of the total radioactivity present in the desired chemical form, such as free pertechnetate versus bound tracer, measured by methods like chromatography.
- free pertechnetate
- Related: radiochemical purity, tagging efficiency
Unbound technetium-99m that has not attached to the labeling agent; it accumulates in thyroid, stomach, and salivary tissue and degrades image quality when present in excess.
- tagging efficiency
- Related: radiochemical purity, free pertechnetate
The percentage of radioactivity successfully bound to the radiopharmaceutical molecule during preparation, a practical measure of how much usable tracer is available for injection.
- half-life
- Related: effective half-life, decay correction
The time required for half of the atoms in a radioactive sample to decay; physical half-life is fixed for each isotope while biologic and effective half-lives describe clearance from the body.
- effective half-life
- Related: half-life, decay correction
The combined result of physical decay and biologic clearance, describing how quickly activity in a patient's body actually falls; it is always shorter than either component half-life.
- decay correction
- Related: half-life, dose calibrator
Mathematical adjustment of measured or prescribed activity for radioactive decay between the calibration time and the time of use or imaging.
- dose calibrator
- Related: decay correction, constancy check
A well-type ionization chamber used to measure the activity of radiopharmaceutical doses before administration, requiring daily constancy checks and periodic accuracy testing.
- constancy check
- Related: dose calibrator, quality control
A daily quality test confirming that a dose calibrator, gamma camera, or other instrument responds consistently to a known source, detecting drift before it affects patient studies.
- energy resolution
- Related: photopeak, pulse height analyzer
The ability of a gamma camera or detector to distinguish gamma rays of similar energy, usually expressed as the full width at half maximum of a photopeak.
- photopeak
- Related: energy resolution, pulse height analyzer
The peak in a gamma spectrum produced when a gamma ray deposits its full energy in the detector, used to set the energy window for imaging.
- pulse height analyzer
- Related: photopeak, scatter
Electronic circuitry that accepts detector signals falling within a chosen energy window and rejects scattered or background events outside that range.
- scatter
- Related: pulse height analyzer, attenuation correction
Gamma photons that change direction and lose energy through Compton interactions in the patient or detector; scatter degrades contrast and is reduced by energy windowing and correction algorithms.
- collimator
- Related: spatial resolution, sensitivity
A lead device placed in front of the camera crystal with holes that restrict incoming photons to a preferred direction, trading sensitivity for spatial resolution.
- spatial resolution
- Related: collimator, sensitivity
The smallest separation at which two point sources can still be distinguished in an image, commonly reported as full width at half maximum in millimeters.
- sensitivity
- Related: collimator, spatial resolution
The number of detected counts per unit of activity for a given imaging system and collimator, reflecting how efficiently emitted photons are captured.
- uniformity
- Related: quality control, constancy check
A measure of how evenly a gamma camera images a uniform flood source; poor uniformity produces ring or spot artifacts and is assessed with daily flood images.
- quality control
- Related: uniformity, constancy check
The scheduled testing program that verifies equipment and radiopharmaceutical performance against accepted standards, including daily, weekly, and periodic tests.
- ALARA
- Related: shielding, occupational dose
The principle of keeping radiation exposure as low as reasonably achievable by using time, distance, and shielding while still obtaining the needed diagnostic information.
- occupational dose
- Related: ALARA, personnel dosimeter
Radiation dose received by a worker during job duties, monitored with a personal dosimeter and compared against annual regulatory limits.
- personnel dosimeter
- Related: occupational dose, ALARA
A badge or ring worn to record cumulative radiation exposure of an individual worker, typically read periodically by a monitoring service.
- Hounsfield unit
- Related: window width and level, attenuation correction
A scaled CT number expressing tissue attenuation relative to water, where water is zero, air is about minus 1000, and dense bone is strongly positive.
- window width and level
- Related: Hounsfield unit, CTDIvol
Display settings that map a range of CT numbers to visible gray shades; level sets the center and width sets the range, controlling contrast and brightness.
- pitch
- Related: CTDIvol, dose-length product
In helical CT, the table travel per gantry rotation divided by the beam collimation; higher pitch speeds coverage but can affect image noise and dose.
- CTDIvol
- Related: dose-length product, pitch
Volume computed tomography dose index, an estimate of the average absorbed dose within the scanned volume for a given protocol, displayed on the scanner console.
- dose-length product
- Related: CTDIvol, pitch
The product of CTDIvol and scan length, used to estimate total radiation output for a CT examination and to compare protocols.
- attenuation correction
- Related: Hounsfield unit, scatter
Correction of PET or SPECT images for photon loss as signal passes through body tissue, typically using a CT-derived map so deeper structures are not falsely shown as cold.
- standardized uptake value
- Related: maximum intensity projection, attenuation correction
A semiquantitative PET metric comparing lesion activity to injected dose and body size, used to help distinguish benign from malignant uptake and to track response.
- maximum intensity projection
- Related: standardized uptake value, coincidence detection
A three-dimensional rendering that displays the brightest voxel along each viewing ray, commonly used to survey whole-body PET images quickly.
- coincidence detection
- Related: time of flight, maximum intensity projection
The PET principle of recording two annihilation photons detected nearly simultaneously on opposite sides of the detector ring, which defines a line of response.
- time of flight
- Related: coincidence detection, attenuation correction
A PET capability that measures small arrival-time differences between annihilation photons to localize the event along the line of response, improving signal-to-noise.
- radiotracer extravasation
- Related: infiltration, injection site
Leakage of injected activity into tissue around the vein, which can cause false nodal uptake, alter dosimetry, and require documentation and follow-up.
- infiltration
- Related: radiotracer extravasation, injection site
Delivery of a radiopharmaceutical or contrast agent into surrounding tissue rather than the vein, potentially causing local irritation and invalidating uptake measurements.
- venipuncture
- Related: injection site, infiltration
Puncture of a vein to administer a radiopharmaceutical or withdraw blood, requiring proper site selection, aseptic technique, and safe sharps handling.
- injection site
- Related: venipuncture, radiotracer extravasation
The location chosen for administering a radiopharmaceutical; it should be documented and imaged when needed to identify dose infiltration or residual activity.
- myocardial perfusion imaging
- Related: reversible defect, fixed defect
Nuclear cardiology study using tracers taken up by heart muscle to assess blood flow at stress and rest, revealing ischemia or scar.
- reversible defect
- Related: fixed defect, myocardial perfusion imaging
A perfusion abnormality present on stress images but normal on rest images, indicating tissue that is ischemic but still viable.
- fixed defect
- Related: reversible defect, myocardial perfusion imaging
A perfusion abnormality seen on both stress and rest images, usually representing scar from prior infarction rather than reversible ischemia.
- gated SPECT
- Related: myocardial perfusion imaging, ejection fraction
Acquisition synchronized to the electrocardiogram so images can be binned by cardiac phase, allowing assessment of wall motion and ejection fraction.
- ejection fraction
- Related: gated SPECT, myocardial perfusion imaging
The percentage of ventricular volume ejected per heartbeat, derived from gated studies or blood pool imaging to evaluate systolic function.