CO Plumber flashcards
CO Plumber · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Water column pressure
- One foot of vertical water column creates 0.433 psi of static pressure; conversely, 2.31 feet of water column equals 1 psi of pressure.
- Drainage slope requirement
- Horizontal drainage pipe 2-1/2 inches and smaller must slope at least 1/4 inch per foot; 3-inch and larger pipe must slope at least 1/8 inch per foot.
- Air gap definition
- The unobstructed vertical distance through free atmosphere between the lowest opening of a water supply outlet and the flood level rim of the fixture or receptacle it serves.
- Backflow causes
- Backflow is reverse flow of water in a piping system caused either by backsiphonage from negative supply pressure or by backpressure downstream of a cross-connection.
- Trap seal depth range
- Every fixture trap must maintain a water seal of at least 2 inches and not more than 4 inches, blocking sewer gas while still allowing the fixture to drain freely.
- Excavation protective threshold
- Excavations 5 feet deep or more require a protective system such as sloping, shoring, or a trench shield; excavations deeper than 20 feet need design by a registered engineer.
- Vent terminal above roof
- A vent stack must extend at least 6 inches above the roof surface, and higher where the roof is used for purposes other than weather protection.
- Confined space oxygen range
- Atmospheric testing before entry must show oxygen between 19.5 and 23.5 percent by volume, with flammable and toxic gases below established exposure limits.
- Copper tube Type K
- Type K copper has the heaviest wall thickness of the three common types and is marked green; it is used for underground water service and other buried lines.
- Lead-free solder definition
- Solder and flux used to join potable water piping must contain no more than 0.2 percent lead and must be labeled as lead-free by the manufacturer.
- Dielectric union purpose
- A dielectric union or nipple separates copper pipe from steel or galvanized pipe, breaking the electrical path that drives galvanic corrosion between dissimilar metals.
- PVC primer requirement
- Solvent-welded PVC joints require listed purple primer applied to both the pipe end and fitting socket before cement, followed by a quarter-turn during assembly.
- PEX joining methods
- PEX is joined only with mechanical insert fittings using copper crimp rings, stainless steel clamp rings, or approved compression fittings; solvent cement is never used on PEX.
- Hubless cast iron joint
- No-hub cast iron soil pipe is joined by a neoprene gasket sleeve compressed with a stainless steel band clamp, which allows slight flexibility and misalignment.
- Thrust block function
- Concrete thrust blocks are poured against fittings at bends, tees, and reducers on buried pressure pipe to transfer water thrust into the surrounding soil.
- Copper support spacing
- Copper tubing 1-1/4 inch and smaller must be supported at least every 6 feet horizontally; 1-1/2 inch and larger tubing every 10 feet.
- T&P relief valve setting
- A temperature and pressure relief valve on a water heater opens at 210 degrees F or 150 psi, whichever occurs first, and must be rated for the heater input.
- T&P discharge pipe rules
- Relief discharge must be full size, flow by gravity, have no valves or traps, and terminate unthreaded not more than 6 inches above the floor or outside above grade.
- Thermal expansion control
- A water heater installed in a closed system with a check valve, pressure-reducing valve, or backflow preventer requires an expansion tank or other approved expansion control device.
- FVIR water heaters
- Gas-fired water heaters must be listed as flammable vapor ignition resistant, using a sealed burner compartment and flame arrestor to prevent ignition of vapors near the floor.
- Sediment trap location
- A sediment trap, or drip leg, is required on the gas piping at each appliance, installed downstream of the appliance shutoff valve and as close as practical to the inlet.
- Fixture residual pressure
- Flowing water pressure at a fixture outlet must be at least 8 psi; flushometer valves serving water closets and urinals require at least 15 psi to operate properly.
- Water closet spacing
- A water closet must have at least 15 inches from its centerline to any sidewall and at least 21 inches of clear space measured in front of the bowl.
- Shower valve type
- Shower control valves must be of the pressure-balancing or thermostatic mixing type so that changes in supply pressure or temperature do not cause scalding.
- Permit requirement
- A permit must be obtained before installing, altering, or replacing plumbing piping, fixtures, or water heaters, unless the specific work is listed as an exemption in the code.
- Rough-in inspection
- The rough-in inspection is requested after drainage, vent, and water piping are installed and tested, but before any of that piping is covered or concealed.
- Final inspection timing
- The final inspection is requested after fixtures are set, appliances are connected, and the system has been tested and is ready for use.
- Colorado Plumbing Code basis
- Colorado adopts the International Plumbing Code together with state amendments as the Colorado Plumbing Code, administered through the State Plumbing Board.
- DWV water test
- Drain, waste, and vent piping is tested with water under a 10-foot head held for at least 15 minutes with no loss of level, or by an approved air test.
- Master plumber role
- In Colorado the master plumber is the licensee authorized to contract for plumbing work, obtain permits, and supervise journeymen and apprentices on the job.
- Concealed work exposure
- If piping is covered before the required inspection, the code official may order the covering removed so the work can be examined and tested.
- Alternative material approval
- The code official may approve materials or methods not named in the code when evidence shows they are equivalent in quality, strength, effectiveness, and safety.