CT HVAC · Get comfortable with the vocabulary.

Lockout/Tagout

A safety procedure in which energy sources are shut off, isolated, and marked with a lock and tag so equipment cannot be started while someone is servicing it.

Related: Personal Protective Equipment (PPE)
Personal Protective Equipment (PPE)

Gear worn to reduce injury risk on the job, such as safety glasses, gloves, hard hats, respirators, and hearing protection, selected for the hazards of the specific task.

Related: Lockout/Tagout
Refrigerant Recovery

The process of removing refrigerant from a system and storing it in an approved container rather than venting it, so it can be reused, recycled, or reclaimed.

Related: Section 608 Certification, Vacuum Pump
Section 608 Certification

A federal EPA credential required for technicians who service, maintain, or dispose of equipment containing regulated refrigerants; passing a proctored exam proves the required knowledge.

Related: Refrigerant Recovery
Carbon Monoxide

An odorless, colorless gas produced by incomplete combustion that can cause illness or death; testing flue gases and ensuring adequate venting guards against dangerous levels in a building.

Related: Combustion Analysis, Heat Exchanger
Manifold Gauge Set

A tool with two gauges and hoses that connects to a system's service ports to read high-side and low-side pressures and to add or remove refrigerant.

Related: Superheat, Subcooling
Vacuum Pump

A pump used to evacuate air and moisture from a refrigeration system before charging, lowering the internal pressure far below atmospheric so trapped water boils off.

Related: Micron Gauge, Refrigerant Recovery
Micron Gauge

An electronic instrument that measures very low absolute pressure in microns, used to confirm that a system has been evacuated to a moisture-free level.

Related: Vacuum Pump
Digital Multimeter

A handheld meter that measures voltage, resistance, and often current and capacitance, used to troubleshoot electrical circuits and components in HVAC equipment.

Related: Ohm's Law, Clamp-On Ammeter
Clamp-On Ammeter

A meter whose jaws wrap around a single conductor to read current by sensing the magnetic field, letting technicians check compressor and fan amp draw without disconnecting wiring.

Related: Digital Multimeter, Overload Protector
Manometer

An instrument that measures gas or air pressure, often in inches of water column, used to read duct static pressure, gas supply pressure, and vent draft.

Related: External Static Pressure, Combustion Analysis
Superheat

The number of degrees a vapor is above its saturation temperature at a given pressure; measuring it at the evaporator outlet shows whether the metering device is feeding properly.

Related: Saturation Temperature, Target Superheat, Thermostatic Expansion Valve (TXV)
Subcooling

The number of degrees a liquid is below its saturation temperature at a given pressure; measuring it at the condenser outlet indicates how much liquid refrigerant is stacked in the condenser.

Related: Saturation Temperature, Manifold Gauge Set
Latent Heat

Heat that changes a substance's state without changing its temperature, such as the heat absorbed when liquid refrigerant boils into vapor in the evaporator.

Related: Sensible Heat, Superheat
Sensible Heat

Heat added to or removed from a substance that changes its temperature and can be felt or measured with a thermometer, as when air is warmed or cooled.

Related: Latent Heat, Delta T
Saturation Temperature

The temperature at which a refrigerant boils at a given pressure; it changes with pressure and is the reference point from which superheat and subcooling are figured.

Related: Pressure–Temperature Relationship, Superheat
Pressure–Temperature Relationship

The fixed pairing between a refrigerant's pressure and its boiling point, which lets a technician use gauge readings to determine the refrigerant's saturation temperature.

Related: Saturation Temperature, Manifold Gauge Set
Ohm's Law

The rule stating that voltage equals current multiplied by resistance (E = I × R); it lets a technician predict one electrical value when the other two are known.

Related: Digital Multimeter, Contactor
Contactor

An electrically controlled switch with a low-voltage coil that closes higher-voltage line contacts to start a compressor, fan motor, or heater element.

Related: Transformer, Overload Protector
Capacitor

A component that stores electrical charge and provides a phase shift or starting torque for motors; a weak or failed one causes hard starting and high amp draw.

Related: Digital Multimeter, Overload Protector
Transformer

A device that changes one alternating voltage to another, commonly stepping 240 or 120 volts down to 24 volts for control circuits and thermostats.

Related: Contactor, Ohm's Law
Overload Protector

A safety device, often a bimetal disc or internal thermal element, that opens the motor circuit when current or temperature gets too high and resets when it cools.

Related: Contactor, Capacitor
External Static Pressure

The resistance to airflow in the duct system connected to a blower, measured in inches of water column across the unit to judge whether the air path is restricted.

Related: Manometer, Airflow (CFM) Verification
MERV Rating

A number from 1 to 16 rating how well an air filter captures particles of a given size; higher ratings stop more particles but add more airflow resistance.

Related: External Static Pressure
Relative Humidity

The percentage of moisture the air holds compared with the maximum it could hold at the same temperature; it affects comfort, coil condensation, and mold risk.

Related: Dew Point, Delta T
Dew Point

The temperature to which air must be cooled for water vapor to condense; duct surfaces below this temperature will sweat and can support mold growth.

Related: Relative Humidity
Heat Exchanger

The metal component in a furnace where combustion gases transfer heat to the circulating air without the two streams mixing; cracks can allow carbon monoxide into the building.

Related: Carbon Monoxide, Combustion Analysis
Induced Draft Blower

A fan mounted at the furnace outlet that pulls combustion products through the heat exchanger and pushes them up the flue, often proving its operation with a pressure switch.

Related: Flue, Combustion Analysis
Flue

The pipe or passage that carries combustion gases from an appliance to the outdoors; it must be properly sized, sloped, and sealed to prevent spillage into the building.

Related: Induced Draft Blower, Carbon Monoxide
Limit Switch

A temperature-actuated safety control that shuts off the burner or heating element if the air in the plenum gets too hot, preventing damage or fire.

Related: Heat Exchanger, Combustion Analysis
AFUE

Annual Fuel Utilization Efficiency, the percentage of fuel energy a heating appliance converts to useful heat over a typical year; higher numbers mean lower operating cost.

Related: Combustion Analysis
Thermostatic Expansion Valve (TXV)

A metering device that regulates refrigerant flow into the evaporator by sensing evaporator temperature and pressure, holding a steady superheat across changing loads.

Related: Superheat, Filter Drier
Filter Drier

A device in the liquid line that traps moisture, dirt, and acids from the refrigerant stream to protect the compressor and prevent ice or restriction in the metering device.

Related: Thermostatic Expansion Valve (TXV), Vacuum Pump
Reversing Valve

A four-way valve in a heat pump that switches refrigerant flow direction so the coil that was the evaporator becomes the condenser, changing the unit between heating and cooling.

Related: Subcooling, Superheat
Delta T

The temperature difference between return air entering the equipment and supply air leaving it; measuring it helps confirm that airflow and refrigerant charge are in a reasonable range.

Related: Airflow (CFM) Verification, Target Superheat
Target Superheat

The superheat value a system should show at a given indoor wet-bulb and outdoor dry-bulb condition, used when charging a fixed-orifice system in the field.

Related: Superheat, Delta T
Commissioning

The process of verifying that a newly installed system is adjusted, balanced, and functioning as designed, including measurements of airflow, charge, and controls before handover to the owner.

Related: Airflow (CFM) Verification, Delta T
Combustion Analysis

Testing flue gases with an electronic analyzer to measure oxygen, carbon dioxide, carbon monoxide, and stack temperature, so the technician can confirm safe and efficient burner operation.

Related: Carbon Monoxide, Heat Exchanger
Airflow (CFM) Verification

Measuring the cubic feet per minute of air moving through the equipment or ducts, using tools such as an anemometer or a traverse, to confirm the blower delivers the designed amount.

Related: External Static Pressure, Delta T
Balancing Damper

An adjustable plate inside a duct that changes its free area, used to direct air to the right rooms and set the desired airflow split during air balancing.

Related: Airflow (CFM) Verification, External Static Pressure