CT HVAC key terms
CT HVAC · Get comfortable with the vocabulary.
- Lockout/Tagout
- Related: Personal Protective Equipment (PPE)
A safety procedure in which energy sources are shut off, isolated, and marked with a lock and tag so equipment cannot be started while someone is servicing it.
- Personal Protective Equipment (PPE)
- Related: Lockout/Tagout
Gear worn to reduce injury risk on the job, such as safety glasses, gloves, hard hats, respirators, and hearing protection, selected for the hazards of the specific task.
- Refrigerant Recovery
- Related: Section 608 Certification, Vacuum Pump
The process of removing refrigerant from a system and storing it in an approved container rather than venting it, so it can be reused, recycled, or reclaimed.
- Section 608 Certification
- Related: Refrigerant Recovery
A federal EPA credential required for technicians who service, maintain, or dispose of equipment containing regulated refrigerants; passing a proctored exam proves the required knowledge.
- Carbon Monoxide
- Related: Combustion Analysis, Heat Exchanger
An odorless, colorless gas produced by incomplete combustion that can cause illness or death; testing flue gases and ensuring adequate venting guards against dangerous levels in a building.
- Manifold Gauge Set
- Related: Superheat, Subcooling
A tool with two gauges and hoses that connects to a system's service ports to read high-side and low-side pressures and to add or remove refrigerant.
- Vacuum Pump
- Related: Micron Gauge, Refrigerant Recovery
A pump used to evacuate air and moisture from a refrigeration system before charging, lowering the internal pressure far below atmospheric so trapped water boils off.
- Micron Gauge
- Related: Vacuum Pump
An electronic instrument that measures very low absolute pressure in microns, used to confirm that a system has been evacuated to a moisture-free level.
- Digital Multimeter
- Related: Ohm's Law, Clamp-On Ammeter
A handheld meter that measures voltage, resistance, and often current and capacitance, used to troubleshoot electrical circuits and components in HVAC equipment.
- Clamp-On Ammeter
- Related: Digital Multimeter, Overload Protector
A meter whose jaws wrap around a single conductor to read current by sensing the magnetic field, letting technicians check compressor and fan amp draw without disconnecting wiring.
- Manometer
- Related: External Static Pressure, Combustion Analysis
An instrument that measures gas or air pressure, often in inches of water column, used to read duct static pressure, gas supply pressure, and vent draft.
- Superheat
- Related: Saturation Temperature, Target Superheat, Thermostatic Expansion Valve (TXV)
The number of degrees a vapor is above its saturation temperature at a given pressure; measuring it at the evaporator outlet shows whether the metering device is feeding properly.
- Subcooling
- Related: Saturation Temperature, Manifold Gauge Set
The number of degrees a liquid is below its saturation temperature at a given pressure; measuring it at the condenser outlet indicates how much liquid refrigerant is stacked in the condenser.
- Latent Heat
- Related: Sensible Heat, Superheat
Heat that changes a substance's state without changing its temperature, such as the heat absorbed when liquid refrigerant boils into vapor in the evaporator.
- Sensible Heat
- Related: Latent Heat, Delta T
Heat added to or removed from a substance that changes its temperature and can be felt or measured with a thermometer, as when air is warmed or cooled.
- Saturation Temperature
- Related: Pressure–Temperature Relationship, Superheat
The temperature at which a refrigerant boils at a given pressure; it changes with pressure and is the reference point from which superheat and subcooling are figured.
- Pressure–Temperature Relationship
- Related: Saturation Temperature, Manifold Gauge Set
The fixed pairing between a refrigerant's pressure and its boiling point, which lets a technician use gauge readings to determine the refrigerant's saturation temperature.
- Ohm's Law
- Related: Digital Multimeter, Contactor
The rule stating that voltage equals current multiplied by resistance (E = I × R); it lets a technician predict one electrical value when the other two are known.
- Contactor
- Related: Transformer, Overload Protector
An electrically controlled switch with a low-voltage coil that closes higher-voltage line contacts to start a compressor, fan motor, or heater element.
- Capacitor
- Related: Digital Multimeter, Overload Protector
A component that stores electrical charge and provides a phase shift or starting torque for motors; a weak or failed one causes hard starting and high amp draw.
- Transformer
- Related: Contactor, Ohm's Law
A device that changes one alternating voltage to another, commonly stepping 240 or 120 volts down to 24 volts for control circuits and thermostats.
- Overload Protector
- Related: Contactor, Capacitor
A safety device, often a bimetal disc or internal thermal element, that opens the motor circuit when current or temperature gets too high and resets when it cools.
- External Static Pressure
- Related: Manometer, Airflow (CFM) Verification
The resistance to airflow in the duct system connected to a blower, measured in inches of water column across the unit to judge whether the air path is restricted.
- MERV Rating
- Related: External Static Pressure
A number from 1 to 16 rating how well an air filter captures particles of a given size; higher ratings stop more particles but add more airflow resistance.
- Relative Humidity
- Related: Dew Point, Delta T
The percentage of moisture the air holds compared with the maximum it could hold at the same temperature; it affects comfort, coil condensation, and mold risk.
- Dew Point
- Related: Relative Humidity
The temperature to which air must be cooled for water vapor to condense; duct surfaces below this temperature will sweat and can support mold growth.
- Heat Exchanger
- Related: Carbon Monoxide, Combustion Analysis
The metal component in a furnace where combustion gases transfer heat to the circulating air without the two streams mixing; cracks can allow carbon monoxide into the building.
- Induced Draft Blower
- Related: Flue, Combustion Analysis
A fan mounted at the furnace outlet that pulls combustion products through the heat exchanger and pushes them up the flue, often proving its operation with a pressure switch.
- Flue
- Related: Induced Draft Blower, Carbon Monoxide
The pipe or passage that carries combustion gases from an appliance to the outdoors; it must be properly sized, sloped, and sealed to prevent spillage into the building.
- Limit Switch
- Related: Heat Exchanger, Combustion Analysis
A temperature-actuated safety control that shuts off the burner or heating element if the air in the plenum gets too hot, preventing damage or fire.
- AFUE
- Related: Combustion Analysis
Annual Fuel Utilization Efficiency, the percentage of fuel energy a heating appliance converts to useful heat over a typical year; higher numbers mean lower operating cost.
- Thermostatic Expansion Valve (TXV)
- Related: Superheat, Filter Drier
A metering device that regulates refrigerant flow into the evaporator by sensing evaporator temperature and pressure, holding a steady superheat across changing loads.
- Filter Drier
- Related: Thermostatic Expansion Valve (TXV), Vacuum Pump
A device in the liquid line that traps moisture, dirt, and acids from the refrigerant stream to protect the compressor and prevent ice or restriction in the metering device.
- Reversing Valve
- Related: Subcooling, Superheat
A four-way valve in a heat pump that switches refrigerant flow direction so the coil that was the evaporator becomes the condenser, changing the unit between heating and cooling.
- Delta T
- Related: Airflow (CFM) Verification, Target Superheat
The temperature difference between return air entering the equipment and supply air leaving it; measuring it helps confirm that airflow and refrigerant charge are in a reasonable range.
- Target Superheat
- Related: Superheat, Delta T
The superheat value a system should show at a given indoor wet-bulb and outdoor dry-bulb condition, used when charging a fixed-orifice system in the field.
- Commissioning
- Related: Airflow (CFM) Verification, Delta T
The process of verifying that a newly installed system is adjusted, balanced, and functioning as designed, including measurements of airflow, charge, and controls before handover to the owner.
- Combustion Analysis
- Related: Carbon Monoxide, Heat Exchanger
Testing flue gases with an electronic analyzer to measure oxygen, carbon dioxide, carbon monoxide, and stack temperature, so the technician can confirm safe and efficient burner operation.
- Airflow (CFM) Verification
- Related: External Static Pressure, Delta T
Measuring the cubic feet per minute of air moving through the equipment or ducts, using tools such as an anemometer or a traverse, to confirm the blower delivers the designed amount.
- Balancing Damper
- Related: Airflow (CFM) Verification, External Static Pressure
An adjustable plate inside a duct that changes its free area, used to direct air to the right rooms and set the desired airflow split during air balancing.