DE Electrician study materials
DE Electrician study resources

DE Electrician cheat sheet

DE Electrician · Keep the key ideas within reach.

Quick reference

Delaware Electrician Licensing Requirements

  • Delaware licenses electricians through the Board of Electrical Examiners under the Division of Professional Regulation; the license types are Master Electrician, Journeyperson Electrician, and Limited Electrician (with apprentice registration separate).

  • Master Electrician applicants must document substantial qualifying field experience (commonly cited as 7 years of practical experience, with approved training substituting for part of it) and pass the Delaware master examination.

  • Journeyperson applicants typically need about 4 years of documented experience under a licensed electrician plus a passing journeyperson exam score; experience letters must be verifiable and on file before the exam.

  • The Delaware electrician examination is administered by a contracted testing vendor; approval from the Board must be obtained before scheduling, and passing scores are reported to the Board by the vendor.

  • Delaware requires continuing education for license renewal; licensees must complete the Board-specified hours per renewal cycle, and CE providers/courses must be Board-approved to count.

  • Licenses renew on a fixed cycle set by the Board; late renewal triggers a penalty fee, and practicing on an expired or lapsed license is a violation subject to disciplinary action.

  • An applicant must disclose criminal history and any prior license discipline; the Board reviews each case and may deny or condition licensure based on the facts.

  • Delaware issues a Limited Electrician license for restricted scope work; the scope limits what the holder may install or service, and work outside that scope requires a master or journeyperson.

  • A licensed master electrician is the party responsible for obtaining electrical permits and for the code-compliant performance of work done under that license, including work by employees.

Quick reference

Electrical Theory and Principles

  • Ohm's law: E = I × R; I = E ÷ R; R = E ÷ I. Applies to DC circuits and to AC circuits where impedance is purely resistive.

  • Power in a resistive circuit: P = E × I = I²R = E² ÷ R. In AC circuits, real power P = E × I × power factor.

  • Series circuit rules: current is the same through every element, voltage divides in proportion to resistance, and total resistance is the sum of individual resistances.

  • Parallel circuit rules: voltage is the same across every branch, branch currents sum to total current, and total resistance is less than the smallest branch resistance (1/RT = 1/R1 + 1/R2 + ...).

  • AC impedance combines resistance and reactance: Z = √(R² + X²); inductive reactance XL = 2πfL, capacitive reactance XC = 1 ÷ (2πfC).

  • Three-phase power: P = √3 × E × I × power factor for a balanced load; single-phase 240 V loads draw half the current of the same kVA at 120 V.

  • Ampacity and voltage drop: voltage drop in a conductor is Vd = 2 × I × R × L for single-phase two-wire circuits (multiply by √3 for three-phase), and excessive drop reduces delivered voltage.

  • Conductor resistance rises with temperature and with length, and falls with increased cross-sectional area; skin effect pushes AC current toward the conductor surface at high frequency.

  • Transformer action: primary-to-secondary voltage ratio equals turns ratio; power in equals power out (minus losses), so a step-down in voltage is a step-up in current.

Quick reference

National Electrical Code Application

  • Article 100 definitions control: a branch circuit is the circuit conductors between the final overcurrent device and the outlets; a feeder runs from service equipment to the final branch-circuit overcurrent device.

  • Continuous loads are calculated at 125% of the load for overcurrent device and conductor sizing (NEC 210.19 and 210.20), and the 80% rule applies to the continuous-load portion of a circuit.

  • Standard overcurrent device ratings are 15, 20, 30, 40, 50, 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250, 300, 350, 400 A and upward; the next-higher standard rating may be used only where permitted by 240.4.

  • Working clearances at electrical equipment are governed by NEC 110.26: 36 in deep for 0–150 V to ground, 42 in for 151–600 V, and 48 in for higher voltages, with 30 in wide clear space and 6 ft 6 in of headroom.

  • GFCI protection is required in bathrooms, garages, outdoors, kitchens (countertop receptacles), laundry areas, unfinished basements, and other locations listed in 210.8; AFCI protection is required for most 120 V branch circuits in dwelling units per 210.12.

  • Receptacle spacing in dwelling units: not more than 12 ft apart along the wall, and no point on the wall more than 6 ft from a receptacle (210.52).

  • Equipment grounding conductors must be sized per NEC 250.122 based on the rating of the overcurrent device protecting the circuit, not on the circuit conductor size.

  • Box fill is calculated per NEC 314.16 by counting conductor volumes, device yokes, and clamps against the cubic-inch capacity of the box.

  • The NEC is adopted locally by cycle; Delaware jurisdictions enforce the adopted edition, and local amendments may be stricter than the model code, so always confirm the edition in force.

Quick reference

Electrical Installation

  • Cable and raceway support: NM cable must be secured within 12 in of boxes and supported every 4.5 ft; EMT must be supported within 3 ft of boxes and every 10 ft.

  • Bending radius and conduit fill: use the NEC Chapter 9 tables and Annex C for fill, and keep bends within the raceway's permitted radius to avoid conductor damage.

  • Conductor identification: grounded conductor is white or gray, equipment grounding conductor is green, green with yellow stripe, or bare, and ungrounded conductors are other colors; the high-leg of a 4-wire delta is orange.

  • Terminations must be made with listed connectors and torqued to the manufacturer's specification; aluminum conductors require AL-rated devices and oxide-inhibiting compound where specified.

  • Panelboard installation: neutrals and grounds are bonded only at the service (main bonding jumper); in subpanels the neutral bar must be isolated from the enclosure and grounding bar.

  • Grounding electrode system: a ground rod must be 8 ft in contact with soil and supplemented by an additional electrode unless a single electrode has 25 ohms or less resistance (250.53).

  • Motor branch circuits use Article 430: overload protection is sized to the motor nameplate, while short-circuit and ground-fault protection is sized from Table 430.52 percentages.

  • Wiring methods in wet or damp locations require listed wet-location fittings and conductors; boxes in wet locations must be listed for the purpose and arranged to drain.

Quick reference

Safety and Inspection

  • Lockout/tagout: de-energize, verify with a tester rated for the voltage, apply a lock and tag, and treat circuits as energized until tested and proven dead.

  • NFPA 70E establishes approach boundaries: the limited approach boundary restricts unqualified persons, and the restricted approach boundary requires qualified persons with appropriate PPE.

  • Arc-rated PPE and clothing are selected from an incident-energy analysis or the PPE category tables in NFPA 70E, matched to the available fault current and clearing time.

  • Personal protective equipment for electrical work includes voltage-rated gloves with leather protectors, arc-rated face protection, and insulated tools rated for the voltage involved.

  • Temporary power and GFCI protection: receptacles used for construction must have GFCI protection, and extension cords must be listed, undamaged, and rated for the load.

  • Inspection sequence: rough-in inspection before concealment, then final inspection after devices and equipment are installed and labeled; the authority having jurisdiction may require corrections before energizing.

  • A permit and inspection are required for new services, panel changes, and major circuit additions; work performed without a permit can be ordered removed or re-inspected at the owner's cost.

  • Test instruments must be rated for the category of the circuit being tested (CAT III or CAT IV for service and distribution work); using an under-rated meter risks arc flash.

Quick reference

Delaware Jurisdiction, Permits, and Enforcement

  • Electrical work in Delaware is permitted and inspected at the local level (city or county) or by the state where no local authority exists; the authority having jurisdiction enforces the adopted code edition.

  • Permit applications typically require the licensed contractor's name and license number, a scope description, and payment of fees before work begins.

  • Inspection failures generate a correction notice; the contractor must correct the listed items and request a re-inspection, and repeated failures may trigger additional fees or Board referral.

  • Unlicensed contracting is enforceable by the Board and local authorities; penalties can include fines, stop-work orders, and denial of future licensure.

  • Delaware requires the license to be displayed or available and the license number to appear on advertisements and contracts as required by Board regulation.

  • Code adoption in Delaware follows the state's adoption cycle; local jurisdictions may adopt a different NEC edition or add amendments, so confirm the edition with the AHJ before design.

  • The Board can discipline a licensee for code violations, failure to obtain permits, abandonment of work, or fraud; discipline ranges from reprimand to revocation and civil penalty.

Quick reference

Load Calculations and Service Sizing

  • General lighting load for dwellings is 3 VA per square foot; small-appliance and laundry branch circuits are 1,500 VA each, subject to demand factors in Table 220.42.

  • Standard method service calculation: sum general lighting, small appliance, laundry, and appliance loads, apply demand factors, then add the largest motor at 25% and compare with the service rating.

  • Optional method for dwellings (Article 220 Part IV) uses the larger of 100% of the first 10 kVA plus 40% of the remainder of general loads, or the nameplate-based calculation.

  • Fixed appliance loads are taken at nameplate rating; four or more appliances may use the 75% demand factor where the conditions of 220.53 are met.

  • Range and dryer loads use Table 220.55 demand factors rather than simple addition when multiple units are supplied by one feeder.

  • Service and feeder conductors are sized to the calculated load and then checked against the overcurrent device; the neutral load may be reduced per 220.61.

  • Ampacity adjustments: apply Table 310.15(B)(2)(a) for ambient temperature and Table 310.15(B)(3)(a) for more than three current-carrying conductors in a raceway.

Quick reference

Grounding, Bonding, and Overcurrent Protection

  • System grounding: the service neutral is grounded at the service disconnect through the main bonding jumper, creating the low-impedance fault path required for overcurrent devices to operate.

  • Grounding electrode conductor sizing follows Table 250.66 based on the largest ungrounded service conductor; equipment grounding conductors follow Table 250.122 based on the overcurrent device rating.

  • Bonding jumpers around water meters, gas piping, and structural steel keep metallic systems at the same potential and prevent arcing during faults.

  • Separately derived systems require their own grounding electrode and bonding jumper, with the neutral-to-ground bond made at the source and not repeated downstream.

  • Overcurrent devices protect conductors from overload and short circuit; the conductor ampacity must be at least the device rating except where 240.4(E) or (G) permits tap or motor exceptions.

  • Fuses and circuit breakers must be selected for the available fault current; a device with an interrupting rating below the available fault current can fail catastrophically.

  • Series-rated systems are permitted only where the combination is listed and marked; replacing a component with an unlisted device voids the rating.

Quick reference

Motors, Controls, and Special Equipment

  • Motor full-load current comes from NEC Tables 430.247 through 430.250 by horsepower and voltage, not from the nameplate, for conductor and protection sizing.

  • Motor overload protection is based on the nameplate service factor and temperature rise; running overload devices are typically sized at 115%–125% of nameplate current per 430.32.

  • Short-circuit and ground-fault protection for motors uses Table 430.52 percentages of full-load current, with the next standard size permitted if the calculated value does not correspond to a standard rating.

  • Motor disconnecting means must be within sight of the controller and motor, or capable of being locked open where not within sight (430.102).

  • Controllers must be sized to the motor horsepower and voltage, and the disconnect must be rated for at least 115% of the motor full-load current.

  • HVAC equipment uses Article 440: the nameplate minimum circuit ampacity sizes the conductors, and the maximum overcurrent device rating protects the equipment.

  • Fire pump, elevator, and emergency system circuits have special requirements in Articles 695, 620, and 700 that override general wiring rules.

Quick reference

Wiring Methods and Raceway Systems

  • NM-B cable is permitted in dwellings but not in wet locations, in masonry, or where subject to physical damage; it must be protected by conduit where exposed to damage.

  • EMT is permitted in dry and wet locations with listed fittings; it requires support within 3 ft of a box and every 10 ft, and must be reamed to protect conductor insulation.

  • PVC conduit expands with temperature; expansion fittings are required for long runs, and PVC is not permitted in hazardous locations where the code restricts it.

  • Liquidtight flexible metal conduit is permitted in wet locations with listed fittings and is commonly used for motor connections; it must be supported per 350.30.

  • MC cable and AC cable have different grounding means: MC has a separate equipment grounding conductor, while AC uses the armor as the grounding path with a bonding strip.

  • Raceway fill limits: 53% for one conductor, 31% for two, and 40% for three or more conductors in a raceway, per Chapter 9 Table 1.

  • Boxes must be accessible; junction boxes cannot be buried in walls or ceilings, and covers must be installed to protect the enclosure.

Quick reference

Hazardous Locations and Special Environments

  • Class I locations contain flammable gases or vapors; Division 1 is where the hazard exists under normal conditions, Division 2 where it exists only under abnormal conditions.

  • Class II locations contain combustible dust, and Class III locations contain ignitable fibers; each class has its own grouping and temperature requirements in Articles 500–506.

  • Zone classifications (Zone 0, 1, 2 for gas; Zone 20, 21, 22 for dust) are an alternative international-style system; equipment must be marked for the zone and gas group.

  • Intrinsically safe circuits limit energy so that no spark can ignite the atmosphere; they must be separated from other circuits and identified per Article 504.

  • Equipment in classified locations must be marked with its class, division or zone, and gas or dust group; substituting unmarked equipment is a code violation.

  • Bathrooms, swimming pools, and fountains have specific bonding and GFCI requirements; pool bonding must connect all metal parts and the water per Article 680.

  • Emergency systems and legally required standby systems must be separate from normal wiring and tested periodically per Articles 700 and 701.

Quick reference

Boxes, Devices, and Equipment Installation

  • Box fill counting: each current-carrying conductor counts as one volume, each device yoke counts as two conductor volumes, and each clamp counts as one, unless the box is marked otherwise.

  • Receptacles in dwelling units must be tamper-resistant where required by 406.12, and all receptacles must be grounded and listed for the application.

  • Switch and receptacle mounting heights are not fixed by the NEC but are set by local practice or the project specification; verify with the AHJ or drawings.

  • Boxes must be supported independently of the raceway or cable unless the box is listed for support by the raceway; a box must be rigidly and securely fastened.

  • Device boxes in walls must be flush with or project slightly from the finished surface; gaps larger than 1/8 in require a listed extension ring or spacer.

  • Luminaires must be listed and installed per the manufacturer's instructions; recessed fixtures require thermal protection and clearance from insulation as marked.

  • Appliances and equipment must be installed per their listing and instructions, and disconnects must be within sight where the code requires them.