DE Electrician · Get comfortable with the vocabulary.

Ampacity

The maximum continuous current, in amperes, that a conductor or cable can carry under stated conditions without exceeding its temperature rating. It depends on conductor size, insulation type, ambient temperature, and how many current-carrying conductors share a raceway.

Related: Conductor Ampacity Adjustment, Overcurrent Protective Device, Ambient Temperature Correction
Ohm's Law

The relationship stating that voltage equals current multiplied by resistance (E = I × R). It lets an electrician calculate an unknown value when the other two are known, and it underlies voltage drop and load calculations on the job.

Related: Voltage Drop, Power Factor, Series Circuit
Power Factor

The ratio of real power in watts to apparent power in volt-amperes in an alternating-current circuit. A value below one means current and voltage waveforms are out of phase, so more current flows than the useful load alone would require.

Related: Apparent Power, Ohm's Law, Three-Phase Power
Three-Phase Power

Electrical power delivered by three conductors whose voltages are offset by 120 electrical degrees. For a balanced load, real power equals the square root of three times line voltage times line current times power factor.

Related: Power Factor, Wye Connection, Delta Connection
Wye Connection

A transformer or motor winding arrangement in which one end of each of three coils joins at a common neutral point. Line-to-neutral voltage is the line-to-line voltage divided by the square root of three, and a grounded neutral is often available.

Related: Delta Connection, Three-Phase Power, Grounded Conductor
Delta Connection

A winding arrangement in which three coils form a closed loop, with each pair joined end to end. Line voltage equals coil voltage, line current is the square root of three times coil current, and no neutral point exists unless one winding is center-tapped.

Related: Wye Connection, Three-Phase Power, High-Leg Delta
Series Circuit

A circuit in which current has only one path, so the same current flows through every component. Total resistance is the sum of individual resistances, and the source voltage divides among the loads in proportion to their resistance.

Related: Parallel Circuit, Ohm's Law, Voltage Drop
Parallel Circuit

A circuit in which two or more paths connect across the same two points, so voltage across each branch is equal. Total current is the sum of branch currents, and total resistance is always less than the smallest branch resistance.

Related: Series Circuit, Ohm's Law, Neutral
Inductance

The property of a coil that opposes any change in current by storing energy in a magnetic field. It causes current to lag voltage in alternating-current circuits and produces inductive reactance measured in ohms.

Related: Capacitance, Power Factor, Impedance
Capacitance

The ability of two separated conductors to store electric charge, measured in farads. In alternating-current circuits it causes current to lead voltage and produces capacitive reactance that falls as frequency rises.

Related: Inductance, Power Factor, Impedance
Impedance

The total opposition to alternating current flow in a circuit, combining resistance and reactance as a vector quantity and measured in ohms. It determines current when an alternating voltage is applied to a reactive load.

Related: Inductance, Capacitance, Power Factor
Voltage Drop

The loss of voltage along conductors caused by their resistance and reactance while carrying current. Excessive drop causes dim lights, overheated motors, and unreliable equipment operation, so feeders and branch circuits are sized to limit it.

Related: Ampacity, Ohm's Law, Conductor
Grounded Conductor

The circuit conductor that is intentionally connected to earth at the service or source. It carries return current during normal operation and is white or gray in color, unlike the equipment grounding conductor.

Related: Equipment Grounding Conductor, Neutral, Grounding Electrode
Equipment Grounding Conductor

The conductive path that connects metal enclosures and non-current-carrying metal parts to the grounding system. It carries fault current back to the source so an overcurrent device opens, and it is green, green with yellow stripe, or bare.

Related: Grounded Conductor, Bonding Jumper, Ground Fault
Grounding Electrode System

The set of conductive elements in direct contact with the earth, such as ground rods, metal water pipe, and concrete-encased electrodes, that connect the electrical system to earth. It stabilizes voltage to earth and limits surges.

Related: Grounding Electrode Conductor, Bonding Jumper, Equipment Grounding Conductor
Grounding Electrode Conductor

The conductor that connects the grounded circuit conductor or service equipment to the grounding electrode system. Its size is determined by the rating of the service or source rather than by the load.

Related: Grounding Electrode System, Grounded Conductor, Service Equipment
Bonding Jumper

A conductor that ensures electrical continuity between metal parts that must be electrically connected, such as around a water meter or across a removable fitting. It keeps all bonded metal at the same potential to prevent shock and arcing.

Related: Equipment Grounding Conductor, Grounding Electrode System, Ground Fault
Overcurrent Protective Device

A fuse or circuit breaker that opens a circuit automatically when current exceeds its rating for a set time. It protects conductors and equipment from overheating and must be coordinated with conductor ampacity.

Related: Ampacity, Short Circuit, Ground Fault
Ground Fault

Unintended current flow from an energized conductor to ground through a path such as a person, water, or damaged insulation. A ground-fault circuit interrupter detects small imbalances and opens the circuit to prevent shock.

Related: Ground-Fault Circuit Interrupter, Equipment Grounding Conductor, Overcurrent Protective Device
Ground-Fault Circuit Interrupter

A device that compares current leaving and returning on a circuit and trips when the difference reaches a threshold, typically 4 to 6 milliamperes for personnel protection. It is required in bathrooms, kitchens, outdoors, and other wet or damp locations.

Related: Ground Fault, Arc-Fault Circuit Interrupter, Bonding Jumper
Arc-Fault Circuit Interrupter

A device that senses the characteristic current and voltage patterns of a dangerous electrical arc and de-energizes the circuit. It is required for many dwelling-unit branch circuits to reduce the risk of fire from damaged or loose wiring.

Related: Ground-Fault Circuit Interrupter, Overcurrent Protective Device, Branch Circuit
Short Circuit

An accidental low-resistance connection between two energized conductors or between an energized conductor and ground, allowing abnormally high current to flow. The resulting magnetic and thermal forces can damage equipment unless protection operates quickly.

Related: Overcurrent Protective Device, Ground Fault, Available Fault Current
Available Fault Current

The maximum current that a supply system can deliver into a short circuit at a given point. Equipment such as breakers and panelboards must have an interrupting or short-circuit current rating at least equal to this value.

Related: Short Circuit, Overcurrent Protective Device, Service Equipment
Service Equipment

The equipment at the supply end of a premises wiring system that contains the main disconnecting means, overcurrent protection, and metering provisions. It is the point where the utility supply connects to the building's electrical system.

Related: Service Entrance Conductors, Grounding Electrode Conductor, Overcurrent Protective Device
Service Entrance Conductors

The conductors that carry power from the utility service point to the service equipment of a building. Overhead and underground service drops, plus the service lateral, are sized according to calculated load and minimum code requirements.

Related: Service Equipment, Feeder, Ampacity
Feeder

All circuit conductors between the service equipment or source of a separately derived system and the final branch-circuit overcurrent devices. Feeders supply panelboards and subpanels and are sized from the load they carry.

Related: Branch Circuit, Service Entrance Conductors, Panelboard
Branch Circuit

The circuit conductors between the final overcurrent device protecting the circuit and the outlets or utilization equipment it serves. Branch circuits are classified by rating and by the types of loads they are permitted to supply.

Related: Feeder, Panelboard, Overcurrent Protective Device
Panelboard

A single panel or group of panel units containing buses and automatic overcurrent devices, arranged for installation in a cabinet. It distributes power to branch circuits or feeders and provides a place to terminate and identify them.

Related: Branch Circuit, Feeder, Overcurrent Protective Device
Raceway

An enclosed channel designed expressly for holding wires, cables, or busbars, such as conduit, electrical metallic tubing, or wireway. Raceways provide mechanical protection and a path for conductors, and their fill is limited by code.

Related: Conductor Fill, Box Fill, Conductor
Conductor Fill

The percentage of a raceway's internal cross-sectional area occupied by conductors. Limits depend on the number of conductors, and exceeding them makes pulling difficult and traps heat that shortens insulation life.

Related: Raceway, Box Fill, Conductor Ampacity Adjustment
Box Fill

The calculation of required cubic-inch volume for a box based on the number and size of conductors, devices, clamps, and grounding conductors entering it. An undersized box can damage insulation and cause overheating or arcing.

Related: Conductor Fill, Raceway, Junction Box
Conductor Ampacity Adjustment

The reduction applied to a conductor's base ampacity when several current-carrying conductors share a raceway or cable, or when ambient temperature differs from the rating basis. Both factors are applied before comparing to the overcurrent device.

Related: Ampacity, Ambient Temperature Correction, Conductor Fill
Ambient Temperature Correction

A multiplier applied to a conductor's ampacity when the surrounding air or earth is hotter than the temperature basis of the insulation rating. Hot locations such as attics and rooftops often require larger conductors.

Related: Ampacity, Conductor Ampacity Adjustment, Conductor
Conductor

A material, usually copper or aluminum, that carries electric current. Conductors are identified by size in American wire gauge or circular mils, by insulation type, and by the number of strands.

Related: Ampacity, Insulation, Raceway
Insulation

The nonconductive covering on a wire that confines current to its intended path and protects against shock and short circuits. Its material and thickness determine the maximum voltage and temperature the conductor can withstand.

Related: Conductor, Ambient Temperature Correction, Ampacity
Junction Box

An enclosure where conductors are spliced, connected to devices, or pulled through. It must be accessible, properly supported, closed with a cover, and sized by box-fill rules to contain all conductors and fittings safely.

Related: Box Fill, Raceway, Conductor
Delaware Electrical License

A credential issued by the Delaware Board of Electrical Examiners that authorizes a person to perform electrical work in the state. Applicants must meet experience, examination, and fee requirements, and licenses require renewal.

Related: Journeyperson Electrician, Master Electrician, Continuing Education
Master Electrician

The license level that allows a person to perform and supervise electrical work and to qualify a business for electrical contracting. It typically requires more documented experience and a passing score on the licensing examination.

Related: Journeyperson Electrician, Delaware Electrical License, Electrical Contractor
Journeyperson Electrician

A licensed electrician who performs electrical work under the direction of a master electrician or qualifying supervisor. The license requires documented field experience and a passing examination, and it is renewed periodically.

Related: Master Electrician, Delaware Electrical License, Apprenticeship
Electrical Contractor

A business entity that contracts to perform electrical work and must hold a license and employ or be qualified by a licensed master electrician. The contractor is responsible for permits and code-compliant work.

Related: Master Electrician, Permit, Delaware Electrical License
Apprenticeship

A structured on-the-job training program combining paid field work with related classroom instruction under a licensed supervisor. Documented apprenticeship hours count toward the experience required for journeyperson and master license applications.

Related: Journeyperson Electrician, Continuing Education, Delaware Electrical License
Continuing Education

Required coursework that licensed electricians complete before renewing a license to keep current with code changes and safety practice. Hours, subject matter, and documentation rules are set by the state licensing board.

Related: Delaware Electrical License, Apprenticeship, Permit
Permit

Written authorization from a local authority to install or alter electrical work, obtained before the job begins. The permit triggers required inspections and helps ensure the work meets the adopted code.

Related: Inspection, Electrical Contractor, Certificate of Occupancy
Inspection

Review of electrical work by an authority having jurisdiction at stages such as rough-in, service, and final completion. Approval confirms code compliance and is needed before energizing equipment or occupying a building.

Related: Permit, Authority Having Jurisdiction, Certificate of Occupancy
Authority Having Jurisdiction

The organization, office, or individual responsible for enforcing code requirements and approving equipment, materials, and installations. Local inspectors and fire officials commonly serve in this role and may adopt stricter local amendments.

Related: Inspection, Permit, National Electrical Code
Certificate of Occupancy

A document issued by a building official confirming that a structure complies with applicable codes and may be occupied. Final electrical inspection approval is usually required before one is issued for new or renovated buildings.

Related: Inspection, Permit, Authority Having Jurisdiction
National Electrical Code

A widely adopted model code, published by the National Fire Protection Association, that sets minimum requirements for electrical installations. Delaware and its local jurisdictions enforce it, often with amendments and a specific edition in effect.

Related: Authority Having Jurisdiction, Permit, Inspection
Lockout/Tagout

A safety procedure that isolates energy sources and applies locks and warning tags before work begins on equipment. Only the person who applied a lock removes it, preventing accidental energization and release of stored energy.

Related: Personal Protective Equipment, Arc Flash, Qualified Person
Arc Flash

A dangerous release of energy caused by an electric arc through air, producing intense heat, light, pressure, and molten metal. Workers must use appropriate protective equipment and de-energize equipment when feasible.

Related: Personal Protective Equipment, Lockout/Tagout, Qualified Person
Personal Protective Equipment

Clothing and gear such as insulated gloves, eye protection, arc-rated clothing, and hard hats worn to reduce injury from shock, burns, and arc hazards. Selection depends on the task and the energy level present.

Related: Arc Flash, Lockout/Tagout, Qualified Person
Qualified Person

A worker who has demonstrated the skills and knowledge to safely construct, install, inspect, or maintain electrical equipment and who understands the hazards involved. Only qualified persons may work on or near exposed energized parts.

Related: Lockout/Tagout, Personal Protective Equipment, Arc Flash
Working Clearance

The required clear space in front of electrical equipment that allows safe operation and maintenance. Depth, width, and height depend on voltage and conditions, and the space must be kept free of storage.

Related: Panelboard, Service Equipment, Qualified Person
Neutral

The conductor of a circuit that is intentionally grounded at the source and returns current from line-to-neutral loads. It must never be bonded to ground again downstream of the service disconnect.

Related: Grounded Conductor, Panelboard, Equipment Grounding Conductor
High-Leg Delta

A delta-connected system with one winding center-tapped to provide a grounded neutral, giving two 120-volt legs and one leg at about 208 volts to neutral. The high leg must be identified and typically connects only to line-to-line loads.

Related: Delta Connection, Neutral, Three-Phase Power