DE Electrician flashcards
DE Electrician · Build recall with a focused review session.
34 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Delaware master electrician experience
- Applicants for the Delaware master electrician license must document years of qualifying field experience under a licensed electrician, verified in writing, before Board approval to sit the exam.
- Delaware license types
- Delaware issues master, journeyperson, and limited electrician licenses through its Board of Electrical Examiners; each carries a defined scope of work and separate experience and exam requirements.
- Delaware continuing education
- Delaware electricians must complete Board-approved continuing education hours each renewal cycle to keep the license active; unapproved courses do not count toward the requirement.
- Delaware permit responsibility
- In Delaware, the licensed master electrician is responsible for obtaining electrical permits and for ensuring that all work performed under that license complies with the adopted code.
- Ohm's law
- Ohm's law states that voltage equals current times resistance (E = I × R). It is used to find the third quantity when two are known in a resistive circuit.
- Power formula
- Electrical power in a resistive circuit is P = E × I, equivalent to I²R or E²/R. In AC circuits, real power equals E × I × power factor.
- Parallel circuit resistance
- In a parallel circuit, voltage is equal across branches and total resistance is less than the smallest branch. Use 1/RT = 1/R1 + 1/R2 to compute it.
- Three-phase power
- For a balanced three-phase load, real power equals √3 × line voltage × line current × power factor. This formula is used for feeder and service load calculations.
- Continuous load rule
- NEC requires continuous loads, those operating three hours or more, to be calculated at 125% of their rating when sizing branch-circuit conductors and overcurrent protection.
- Working clearance 110.26
- NEC 110.26 requires a minimum 36-inch-deep working space for equipment up to 150 volts to ground, 30 inches wide, and 6 feet 6 inches of headroom.
- GFCI required locations
- GFCI protection is required by NEC 210.8 in bathrooms, garages, outdoors, kitchens, laundry areas, unfinished basements, and other listed locations for personnel protection.
- Equipment grounding conductor sizing
- The equipment grounding conductor is sized from NEC Table 250.122 using the rating of the overcurrent device protecting the circuit, not the size of the circuit conductors.
- Box fill calculation
- NEC 314.16 counts each conductor, device yoke, and clamp as a specific volume in cubic inches, and the total must not exceed the box's marked capacity.
- NM cable support
- Nonmetallic-sheathed cable must be secured within 12 inches of each box and supported at intervals not exceeding 4.5 feet along its run.
- EMT support spacing
- Electrical metallic tubing must be supported within 3 feet of each box and at intervals not exceeding 10 feet, using listed straps and fittings.
- Conductor color identification
- Grounded conductors are white or gray, equipment grounding conductors are green, green with yellow stripe, or bare, and the high-leg of a four-wire delta system is orange.
- Subpanel neutral bonding
- In a subpanel, the neutral bar must be isolated from the enclosure and grounding bar; the neutral-to-ground bond is made only at the service equipment.
- Lockout tagout procedure
- De-energize the circuit, verify absence of voltage with a properly rated tester, apply a lock and tag, and treat conductors as energized until proven otherwise.
- NFPA 70E approach boundaries
- NFPA 70E defines limited and restricted approach boundaries; unqualified persons may not cross the limited boundary, and restricted work requires qualified persons with rated PPE.
- Inspection sequence
- Electrical inspections typically proceed from rough-in, before walls are closed, to final inspection after devices, equipment, and labeling are complete and the system is ready to energize.
- Meter category rating
- Test instruments must carry a CAT rating matching the circuit; CAT III covers distribution and feeder work, and CAT IV covers service and utility-side measurements.
- Delaware permit authority
- Electrical permits in Delaware are issued by the local city or county authority having jurisdiction, or by the state where no local authority exists, and work requires inspection.
- Unlicensed contracting penalty
- Performing electrical contracting in Delaware without a license can result in fines, stop-work orders, permit denial, and refusal of future licensure by the Board.
- Dwelling lighting load
- NEC general lighting load for dwellings is 3 volt-amperes per square foot of floor area, with small-appliance and laundry branch circuits counted separately at 1,500 VA each.
- Ampacity adjustment factors
- Conductor ampacity is adjusted for ambient temperature using Table 310.15(B)(2)(a) and for more than three current-carrying conductors in a raceway using Table 310.15(B)(3)(a).
- Main bonding jumper
- The main bonding jumper connects the grounded service conductor to the service equipment enclosure at the service disconnect, establishing the fault current path to the source.
- Grounding electrode resistance
- A single ground rod must be supplemented by an additional electrode unless it demonstrates 25 ohms or less resistance to earth, per NEC 250.53.
- Motor full-load current tables
- Motor full-load current for conductor and protection sizing comes from NEC Tables 430.247 through 430.250 by horsepower and voltage, not from the motor nameplate.
- Motor overload protection
- Running overload devices protect motors from overheating and are sized from nameplate current, typically 115% to 125%, depending on service factor and temperature rise.
- Raceway fill percentages
- NEC Chapter 9 Table 1 limits raceway fill to 53% for one conductor, 31% for two conductors, and 40% for three or more conductors.
- Class I Division 1
- A Class I Division 1 location is one where flammable gases or vapors are present under normal operating conditions, requiring listed explosionproof equipment and wiring methods.
- Intrinsically safe circuit
- An intrinsically safe circuit limits electrical energy so that no spark or thermal effect can ignite the hazardous atmosphere; it must be separated and identified per Article 504.
- Tamper-resistant receptacles
- NEC 406.12 requires tamper-resistant receptacles in dwelling units and other specified areas to protect children from inserting objects into receptacle slots.
- Luminaire installation
- Luminaires must be listed and installed according to the manufacturer's instructions, with required clearances from insulation and combustible material maintained as marked.