EPA 608 Universal key terms
EPA 608 Universal · Get comfortable with the vocabulary.
- Ozone Depletion Potential (ODP)
- Related: Chlorofluorocarbon (CFC), Hydrofluorocarbon (HFC), Global Warming Potential (GWP)
A number comparing a refrigerant's ability to destroy stratospheric ozone to CFC-11, which is set at 1.0. Higher values indicate greater ozone harm.
- Global Warming Potential (GWP)
- Related: Ozone Depletion Potential (ODP), Hydrofluorocarbon (HFC), A2L refrigerant
A number comparing a refrigerant's heat-trapping effect in the atmosphere to carbon dioxide over a chosen time period. Higher values mean a stronger contribution to climate change.
- Chlorofluorocarbon (CFC)
- Related: Ozone Depletion Potential (ODP), Hydrofluorocarbon (HFC)
A refrigerant class containing chlorine, fluorine, and carbon that strongly depletes stratospheric ozone. CFCs are banned from production and use in most applications.
- Hydrofluorocarbon (HFC)
- Related: Global Warming Potential (GWP), Ozone Depletion Potential (ODP), A2L refrigerant
A refrigerant class containing hydrogen, fluorine, and carbon but no chlorine. HFCs do not deplete ozone but are potent greenhouse gases, such as R-134a and R-410A.
- Zeotropic blend
- Related: Temperature glide, Fractionation, Liquid charging
A refrigerant mixture whose components have different boiling points, producing a temperature glide during phase change. It must be charged as liquid to maintain the intended composition.
- Temperature glide
- Related: Zeotropic blend, Fractionation, Liquid charging
The difference between the bubble point and dew point temperatures of a zeotropic refrigerant blend at a given pressure. It affects charging and system performance.
- Fractionation
- Related: Zeotropic blend, Temperature glide, Liquid charging
The separation of components in a zeotropic blend when it leaks or boils, because components vaporize at different rates. This changes the remaining refrigerant's composition and performance.
- Recovery
- Related: Recycling, Reclaiming, Recovery cylinder
Removing refrigerant from an appliance and storing it in an external container without intentionally processing it. Recovery is required before opening a system or disposing of equipment.
- Recycling
- Related: Recovery, Reclaiming, Non-condensable gases
Cleaning recovered refrigerant by removing oil, moisture, and non-condensables so it can be reused, typically in the same appliance or another appliance owned by the same person.
- Reclaiming
- Related: Recovery, Recycling, Recovery cylinder
Reprocessing used refrigerant to meet the purity specifications of new product, which requires an EPA-certified reclaimer. Reclaimed refrigerant can be sold and used in any appliance.
- De minimis release
- Related: Knowing release, Venting prohibition, Recovery
A refrigerant release small enough that EPA does not require recovery under the venting prohibition. It generally applies only to very small amounts released during service or repair.
- Knowing release
- Related: De minimis release, Venting prohibition, Recovery
Intentionally or knowingly venting refrigerant to the atmosphere, which is prohibited for ozone-depleting refrigerants and their substitutes. Proper recovery is required instead.
- Recovery cylinder
- Related: 80% fill rule, Recovery, Reclaiming
A refillable, DOT-approved cylinder used to hold recovered refrigerant. It must never be filled above 80% of capacity and must be labeled with the refrigerant type.
- 80% fill rule
- Related: Recovery cylinder, Liquid charging
A safety requirement that recovery cylinders be filled to no more than 80% of their capacity by weight, leaving room for liquid expansion and preventing dangerous overpressure.
- Deep vacuum
- Related: Micron, Triple evacuation, Non-condensable gases
A vacuum level low enough, typically below 500 microns, to remove moisture and non-condensable gases from a refrigeration system before charging.
- Micron
- Related: Deep vacuum, Triple evacuation
A unit of vacuum equal to one-thousandth of a millimeter of mercury. Micron gauges measure deep vacuum during evacuation to verify moisture and non-condensables are removed.
- Triple evacuation
- Related: Deep vacuum, Nitrogen purge, Micron
An evacuation method that alternately pulls a vacuum and breaks it with dry nitrogen, repeated three times, to remove moisture and non-condensables from a system.
- Nitrogen purge
- Related: Triple evacuation, Non-condensable gases
Using dry nitrogen to sweep air and moisture from tubing or to displace oxygen during brazing, preventing oxidation inside the system.
- Non-condensable gases
- Related: Nitrogen purge, Deep vacuum, Purge unit
Gases such as air or nitrogen that do not condense at normal system pressures and temperatures. They raise condensing pressure and must be removed by evacuation or purging.
- Liquid charging
- Related: Vapor charging, Zeotropic blend, Fractionation
Adding refrigerant to a system as a liquid, often into the liquid line or receiver. It is required for zeotropic blends to prevent fractionation.
- Vapor charging
- Related: Liquid charging, Fractionation
Adding refrigerant to the low-pressure side as a vapor. It is slower than liquid charging and is used for single-component refrigerants to avoid liquid slugging the compressor.
- A2L refrigerant
- Related: Global Warming Potential (GWP), Hydrofluorocarbon (HFC)
A refrigerant safety classification for mildly flammable fluids under ASHRAE Standard 34. A2L refrigerants require special handling and leak detection because of flammability.
- Venting prohibition
- Related: Knowing release, De minimis release, Recovery
EPA's rule that prohibits knowingly venting ozone-depleting refrigerants and their substitutes during service, maintenance, repair, or disposal. Refrigerant must be recovered instead.
- Small appliance
- Related: System-dependent recovery equipment, Self-contained recovery equipment, Recovery efficiency
EPA's category for household refrigerators, freezers, room air conditioners, dehumidifiers, and similar units with small refrigerant charges, typically five pounds or less.
- System-dependent recovery equipment
- Related: Self-contained recovery equipment, Small appliance, Recovery efficiency
Recovery equipment that relies on the appliance's own compressor to move refrigerant into a recovery container. It is commonly used for small appliances and cannot recover all refrigerant.
- Self-contained recovery equipment
- Related: System-dependent recovery equipment, Recovery efficiency, Small appliance
Recovery equipment with its own compressor that does not depend on the appliance's compressor. It can recover refrigerant faster and to lower levels than system-dependent equipment.
- Recovery efficiency
- Related: System-dependent recovery equipment, Self-contained recovery equipment, Small appliance
The percentage of refrigerant removed from an appliance compared with the amount originally in it. EPA sets minimum recovery efficiency requirements that vary by appliance type and equipment.
- High-pressure appliance
- Related: Very high-pressure appliance, R-410A, Superheat
EPA's equipment category for systems using refrigerants such as R-22, R-410A, and R-134a that operate at relatively high pressures. Type II certification covers these appliances.
- Very high-pressure appliance
- Related: High-pressure appliance, R-410A, Recovery
A Type II appliance that uses a refrigerant operating at pressures higher than R-22, such as R-410A. It requires gauges, hoses, and recovery equipment rated for the higher pressure.
- Superheat
- Related: Subcooling, Saturation temperature, Fixed orifice
The difference between the actual temperature of refrigerant vapor and its saturation temperature at the same pressure. It is used to check charge in systems with a fixed orifice.
- Subcooling
- Related: Superheat, Saturation temperature, Thermostatic expansion valve (TXV)
The difference between the saturation temperature of liquid refrigerant and its actual liquid temperature at the same pressure. It is used to check charge in systems with a thermostatic expansion valve.
- Saturation temperature
- Related: Superheat, Subcooling
The temperature at which a refrigerant changes between liquid and vapor at a given pressure. It is found on a pressure-temperature chart and is used to calculate superheat and subcooling.
- Thermostatic expansion valve (TXV)
- Related: Subcooling, Superheat, Fixed orifice
A metering device that controls refrigerant flow into the evaporator to maintain a set superheat. Systems with a TXV are typically charged by measuring subcooling.
- Fixed orifice
- Related: Superheat, Thermostatic expansion valve (TXV), Saturation temperature
A metering device with a fixed opening that does not adjust to load changes. Systems using a fixed orifice are typically charged by measuring superheat.
- R-410A
- Related: Very high-pressure appliance, Hydrofluorocarbon (HFC), High-pressure appliance
A high-pressure HFC blend used in residential and commercial air conditioning. It requires POE oil and pressure-rated equipment because it operates at higher pressures than R-22.
- Low-pressure appliance
- Related: Chiller, Purge unit, R-123
EPA's category for systems that use low-pressure refrigerants such as R-11 or R-123, typically centrifugal chillers whose evaporators operate in a vacuum.
- Chiller
- Related: Low-pressure appliance, Centrifugal compressor, Purge unit
A machine that cools water or another fluid for building cooling. Large centrifugal chillers often use low-pressure refrigerants and require special recovery and purge procedures.
- Purge unit
- Related: Non-condensable gases, Low-pressure appliance, Chiller
A device on low-pressure chillers that removes air and other non-condensable gases from the refrigerant. It helps maintain efficiency and prevents excessive condensing pressure.
- Centrifugal compressor
- Related: Chiller, Low-pressure appliance, R-123
A high-volume compressor used in large chillers that raises refrigerant pressure using a spinning impeller. It can operate with low-pressure refrigerants and may create a vacuum in the evaporator.
- R-123
- Related: Low-pressure appliance, Chiller, Centrifugal compressor
A low-pressure HCFC refrigerant used mainly in centrifugal chillers. It has a low ozone depletion potential but is being phased out.