EXIN CDCE study materials
EXIN CDCE study resources

EXIN CDCE key terms

EXIN CDCE · Get comfortable with the vocabulary.

Tier Classification (Tier I–IV)

A four-level scheme describing data centre availability and fault tolerance, from a single path with no redundancy to fully fault-tolerant systems with concurrently maintainable site infrastructure. It is used when specifying resilience and comparing design options.

Related: Concurrent Maintainability, Redundancy (N+1, 2N), Fault Tolerance
Concurrent Maintainability

The property of site infrastructure allowing any planned maintenance activity on a component to be performed without shutting down the IT load. It requires redundant capacity paths and careful isolation procedures.

Related: Tier Classification (Tier I–IV), Redundancy (N+1, 2N), Single Point of Failure
Redundancy (N+1, 2N)

Provision of extra capacity beyond the minimum needed to carry the load. N+1 adds one spare unit; 2N duplicates the entire capacity path so either side can carry full load alone.

Related: Tier Classification (Tier I–IV), Single Point of Failure, Uninterruptible Power Supply (UPS)
Single Point of Failure

Any component whose failure causes the whole system or a protected load to stop. Identifying and eliminating such components is central to resilient design reviews.

Related: Redundancy (N+1, 2N), Concurrent Maintainability, Failure Mode and Effects Analysis (FMEA)
Fault Tolerance

The ability of infrastructure to keep serving the IT load despite a failure of any single component, without interruption. It typically requires fully duplicated paths and automatic transfer.

Related: Tier Classification (Tier I–IV), Redundancy (N+1, 2N), Static Transfer Switch
Uninterruptible Power Supply (UPS)

A system that supplies conditioned power from batteries or another stored source during a mains failure or disturbance, bridging the gap until generators start or load is shut down cleanly.

Related: Generator Set, Power Usage Effectiveness (PUE), Static Transfer Switch
Power Usage Effectiveness (PUE)

The ratio of total facility energy consumption to the energy delivered to IT equipment. A value near 1.0 indicates efficient operation; it is used to benchmark and track efficiency improvements.

Related: Data Centre Infrastructure Management (DCIM), Uninterruptible Power Supply (UPS), Cooling Load
Cooling Load

The total heat that must be removed from the data centre to maintain acceptable conditions, comprising IT heat plus heat from lighting, people, and envelope gains. It drives cooling capacity sizing.

Related: Hot/Cold Aisle Containment, Power Usage Effectiveness (PUE), Airflow Management
Hot/Cold Aisle Containment

A layout and physical enclosure strategy that separates cold supply air from hot exhaust air, preventing mixing. It improves cooling efficiency and allows higher supply temperatures.

Related: Airflow Management, Cooling Load, Rack Power Density
Airflow Management

The practice of directing cooled air to where equipment needs it and returning hot air to cooling units, using blanking panels, seals, raised floors, and containment to reduce bypass and recirculation.

Related: Hot/Cold Aisle Containment, Cooling Load, Rack Power Density
Rack Power Density

The electrical load per rack, usually expressed in kilowatts. It determines cooling method, power distribution design, and whether traditional or high-density cooling approaches are required.

Related: Airflow Management, Power Distribution Unit (PDU)
Power Distribution Unit (PDU)

A device that distributes electrical power to racks or equipment, often with metering and switching. Rack PDUs provide outlet-level power delivery and monitoring inside cabinets.

Related: Rack Power Density, Uninterruptible Power Supply (UPS), Busway
Busway

A modular overhead or underfloor power distribution system of enclosed conductors with tap-off points. It allows circuits to be added or relocated without new cable runs.

Related: Power Distribution Unit (PDU), Concurrent Maintainability
Static Transfer Switch

An automatic device that switches a load between two power sources within milliseconds using semiconductor devices, supporting fault tolerance and source maintenance without load interruption.

Related: Fault Tolerance, Uninterruptible Power Supply (UPS)
Generator Set

An engine-driven generator providing backup power during prolonged mains outages. Its rating, fuel autonomy, start time, and testing regime are key design and operational parameters.

Related: Uninterruptible Power Supply (UPS), Load Bank Testing
Load Bank Testing

Deliberately applying an artificial electrical load to a generator or UPS to verify capacity and reliability under realistic conditions, often required for commissioning and periodic maintenance.

Related: Generator Set, Commissioning, Preventive Maintenance
Commissioning

The structured process of verifying that installed systems meet design intent and operate correctly, including component, system, and integrated systems testing before handover to operations.

Related: Integrated Systems Test (IST), Load Bank Testing, Change Management
Integrated Systems Test (IST)

A full-scale test demonstrating that all systems work together under simulated failure conditions, such as a utility outage, before a data centre is accepted for live operation.

Related: Commissioning, Failure Mode and Effects Analysis (FMEA)
Failure Mode and Effects Analysis (FMEA)

A structured method for identifying how components or processes can fail, assessing the severity and likelihood of effects, and prioritizing mitigation actions. It is used in design and operational risk reviews.

Related: Single Point of Failure, Integrated Systems Test (IST), Change Management
Preventive Maintenance

Scheduled, planned servicing of equipment to reduce failure probability and extend life, based on manufacturer guidance, condition data, or time intervals. It is documented and tracked against a maintenance plan.

Related: Condition-Based Monitoring, Load Bank Testing, Computerized Maintenance Management System (CMMS)
Condition-Based Monitoring

Using sensors and trend data, such as temperature, vibration, or current, to decide when maintenance is needed rather than relying on fixed schedules. It supports predictive maintenance decisions.

Related: Preventive Maintenance, Data Centre Infrastructure Management (DCIM), Computerized Maintenance Management System (CMMS)
Computerized Maintenance Management System (CMMS)

Software that records assets, work orders, maintenance schedules, and spares, providing an auditable history of maintenance activity and supporting planning and compliance reporting.

Related: Preventive Maintenance, Change Management, Configuration Management Database (CMDB)
Change Management

A controlled process for planning, reviewing, approving, implementing, and documenting changes to the data centre, reducing the risk of outages caused by uncoordinated modifications.

Related: Configuration Management Database (CMDB), Method of Procedure (MOP), FMEA
Method of Procedure (MOP)

A written, step-by-step document describing how a specific change or maintenance task will be performed, including prerequisites, verification steps, and rollback actions. It is reviewed before execution.

Related: Change Management, Standard Operating Procedure (SOP), Emergency Operating Procedure (EOP)
Standard Operating Procedure (SOP)

A documented routine instruction for performing a recurring operational task consistently and safely, such as a generator test or a guided equipment inspection.

Related: Method of Procedure (MOP), Emergency Operating Procedure (EOP)
Emergency Operating Procedure (EOP)

A predefined response document for handling abnormal events, such as cooling loss or power failure, specifying actions, roles, and escalation to limit impact on services.

Related: Standard Operating Procedure (SOP), Method of Procedure (MOP), Incident Management
Incident Management

The process of detecting, recording, responding to, and resolving unplanned service disruptions, restoring normal operation quickly and capturing lessons for improvement.

Related: Emergency Operating Procedure (EOP), Service Level Agreement (SLA)
Data Centre Infrastructure Management (DCIM)

Software that consolidates asset, power, cooling, and capacity data to give visibility across the facility. It supports planning, efficiency analysis, and informed operational decisions.

Related: Configuration Management Database (CMDB), Power Usage Effectiveness (PUE), Capacity Management
Configuration Management Database (CMDB)

A repository recording configuration items and their relationships, such as servers, circuits, and dependencies. It underpins change planning and impact analysis.

Related: Change Management, Data Centre Infrastructure Management (DCIM)
Capacity Management

Planning and monitoring space, power, cooling, and network resources to ensure current and forecast demand can be met without over-provisioning or risking constraints.

Related: Data Centre Infrastructure Management (DCIM), Service Level Agreement (SLA)
Service Level Agreement (SLA)

A formal agreement defining expected service levels, such as availability, response times, and remedies for shortfalls, between a data centre provider and its customers.

Related: Availability, Incident Management, Capacity Management
Availability

The proportion of time a service is operational and accessible, often expressed as a percentage of agreed service time. It is calculated from uptime and downtime and tied to SLA commitments.

Related: Service Level Agreement (SLA), Fault Tolerance
Business Continuity Plan (BCP)

Documented arrangements for keeping critical business functions running during and after disruption, covering people, processes, and technology dependencies beyond the data centre itself.

Related: Disaster Recovery Plan (DRP), Recovery Time Objective (RTO)
Disaster Recovery Plan (DRP)

A documented set of procedures for restoring IT systems and data after a major disruption, including roles, recovery sequences, and alternate site arrangements. It is tested periodically.

Related: Business Continuity Plan (BCP), Recovery Time Objective (RTO), Recovery Point Objective (RPO)
Recovery Time Objective (RTO)

The maximum acceptable duration to restore a service after disruption. It drives architecture choices such as redundancy, standby sites, and recovery automation.

Related: Recovery Point Objective (RPO), Disaster Recovery Plan (DRP)
Recovery Point Objective (RPO)

The maximum acceptable amount of data loss measured in time, determining how frequently data must be replicated or backed up to meet business expectations.

Related: Recovery Time Objective (RTO), Disaster Recovery Plan (DRP)
Physical Security Controls

Layered measures such as perimeter fencing, access control, visitor management, CCTV, and intrusion detection that protect the facility and equipment from unauthorized access and harm.

Related: Access Control (Multi-Factor), Environmental Monitoring
Access Control (Multi-Factor)

Restricting entry to authorized individuals using credentials such as badges, biometrics, or PINs, often combined, with logging and zone-based permissions to enforce least privilege.

Related: Physical Security Controls, Environmental Monitoring
Environmental Monitoring

Continuous sensing of temperature, humidity, water leakage, smoke, and power conditions, with alerting to detect abnormal conditions before they damage equipment or cause outages.

Related: Physical Security Controls, Cooling Load, Data Centre Infrastructure Management (DCIM)
ISO/IEC 27001

An international standard specifying requirements for an information security management system, including risk assessment, controls, and continual improvement. Certification demonstrates audited compliance.

Related: Audit and Compliance Evidence, Business Continuity Plan (BCP)
ISO/IEC 22237 Series

A series of international standards covering data centre facilities and infrastructures, addressing classification, availability, security, energy efficiency, and related design and operation topics.

Related: Tier Classification (Tier I–IV), Power Usage Effectiveness (PUE)
Audit and Compliance Evidence

Records, logs, test results, and certificates that demonstrate conformity with standards, regulations, and internal policies during internal or external audits.

Related: ISO/IEC 27001, Computerized Maintenance Management System (CMMS)
Regulatory and Legal Requirements

Laws and rules affecting data centre operation, such as data protection, environmental permitting, fire safety, electrical safety, and employment obligations, which must be identified and met.

Related: Audit and Compliance Evidence, Environmental Monitoring