EPI Data Centre Foundation study materials
EPI Data Centre Foundation study resources

EPI Data Centre Foundation key terms

EPI Data Centre Foundation · Get comfortable with the vocabulary.

Availability

The proportion of time a data centre system is capable of performing its intended function, usually expressed as a percentage over an agreed measurement period. It is calculated from uptime and downtime and underpins service commitments made to customers.

Related: Redundancy, Concurrent Maintainability, Service Level Agreement
Redundancy

The provision of extra capacity or duplicate components so that a single failure does not stop the system working. Redundancy can be applied to power, cooling, networks or staff, and is usually described using N, N+1 or 2N notation.

Related: Concurrent Maintainability, Fault Tolerance, Availability
Concurrent Maintainability

The ability to carry out planned maintenance on any part of the infrastructure while the IT load continues to be served without interruption. It is a defining characteristic of higher-tier designs and requires redundant capacity plus documented procedures.

Related: Redundancy, Fault Tolerance, Maintenance Window
Fault Tolerance

The capability of a system to keep operating, without loss of service, when one or more of its components fail. It usually relies on duplicated paths or components and automatic switching, and exceeds simple concurrent maintainability.

Related: Redundancy, Concurrent Maintainability, Single Point of Failure
Single Point of Failure

Any component, path or dependency whose failure would cause the whole system or a critical service to stop. Identifying and removing these is a core objective of resilience design and risk assessment.

Related: Fault Tolerance, Redundancy, Risk Assessment
Uninterruptible Power Supply (UPS)

A battery-backed device that supplies conditioned power to IT equipment for a short period during a mains failure or disturbance, bridging the gap until generators start or the load is shut down cleanly.

Related: Generator, Power Usage Effectiveness, Static Transfer Switch
Power Usage Effectiveness (PUE)

The ratio of total facility energy consumption to the energy delivered to IT equipment. A PUE of 1.0 would mean no overhead; lower values indicate greater energy efficiency and are widely used as a design and reporting metric.

Related: Uninterruptible Power Supply (UPS), Data Centre Infrastructure Management (DCIM), Cooling
Cooling

The systems that remove heat generated by IT equipment and keep inlet temperatures within equipment limits. Approaches include room-based air conditioning, containment, in-row coolers and liquid cooling, and they strongly influence energy use.

Related: Hot and Cold Aisle Containment, Power Usage Effectiveness (PUE), ASHRAE Thermal Guidelines
Hot and Cold Aisle Containment

A layout and physical barrier arrangement that separates cool supply air from hot exhaust air in the white space. It improves cooling efficiency and reduces mixing, allowing higher set points and lower energy consumption.

Related: Cooling, ASHRAE Thermal Guidelines, Power Usage Effectiveness (PUE)
ASHRAE Thermal Guidelines

Industry guidance that defines recommended and allowable ranges for temperature and humidity at IT equipment inlets. It classifies environments into classes and is widely referenced when setting data centre operating envelopes.

Related: Cooling, Hot and Cold Aisle Containment, Service Level Agreement
Static Transfer Switch

An automatic device that transfers an electrical load from one power source to another within milliseconds when the preferred source fails or drifts out of tolerance. It is common in dual-corded distribution designs.

Related: Uninterruptible Power Supply (UPS), Redundancy, Single Point of Failure
Cross-Connection

A physical network or fibre link between two points, often between customers or carriers within a data centre. Cross-connects are a core interconnection product and must be documented and controlled for security and capacity.

Related: Meet-Me Room, Cable Management, Change Management
Meet-Me Room

A controlled space where telecommunications carriers terminate their networks and interconnect with each other and with customers. Access is restricted and cross-connections are typically ordered and recorded through a formal process.

Related: Cross-Connection, Physical Security, Cable Management
Cable Management

The structured routing, labelling and support of power and data cabling to maintain airflow, enable maintenance and prevent errors. Good practice includes separation of power and data and accurate records of every connection.

Related: Cross-Connection, Change Management, Capacity Management
Change Management

A controlled process for planning, approving, implementing and reviewing changes to infrastructure or services. It aims to reduce unintended outages by assessing risk, scheduling work and providing rollback plans before changes occur.

Related: Maintenance Window, Configuration Management, Risk Assessment
Maintenance Window

A pre-agreed period during which planned work, such as testing or repair, may take place with reduced or suspended service. It is defined in the service agreement and coordinated with the customer.

Related: Change Management, Concurrent Maintainability, Service Level Agreement
Configuration Management

The discipline of recording and controlling the components, versions and relationships that make up the infrastructure and services. Accurate configuration data supports change planning, fault diagnosis, audits and capacity decisions.

Related: Change Management, Data Centre Infrastructure Management (DCIM), Capacity Management
Capacity Management

The process of monitoring and planning power, cooling, space, network and staffing resources so demand can be met without overloading systems. It balances current utilisation against forecast growth and contractual commitments.

Related: Configuration Management, Data Centre Infrastructure Management (DCIM), Power Usage Effectiveness (PUE)
Data Centre Infrastructure Management (DCIM)

Software and sensors used to monitor and manage assets, power, cooling and space in a data centre. It provides a live model of the facility that supports capacity planning, efficiency reporting and incident response.

Related: Capacity Management, Configuration Management, Power Usage Effectiveness (PUE)
Physical Security

Layered controls that prevent unauthorised access to facilities and equipment, such as perimeter fencing, access control, CCTV, visitor escorts and locked cabinets. Controls should be proportionate to risk and regularly tested.

Related: Access Control, Meet-Me Room, Risk Assessment
Access Control

The systems and rules that determine who may enter which areas and when, using methods such as badges, biometrics, PINs and logging. Records support investigation and demonstrate compliance during audits.

Related: Physical Security, Audit, Incident Management
Incident Management

The process for detecting, recording, responding to and recovering from unplanned events that affect service. It includes escalation, communication with customers and a post-incident review to prevent recurrence.

Related: Problem Management, Business Continuity Management, Service Level Agreement
Problem Management

The practice of finding and eliminating the underlying causes of recurring incidents. It uses trend analysis and root cause investigation to produce permanent fixes, reducing repeat disruption and improving stability.

Related: Incident Management, Root Cause Analysis, Change Management
Root Cause Analysis

A structured method, such as the five-whys or fishbone diagram, used to identify why an incident happened rather than only what happened. Findings should feed corrective actions and lessons learned.

Related: Problem Management, Incident Management, Risk Assessment
Service Level Agreement (SLA)

A contract between a provider and a customer that defines the service, performance targets such as availability and response times, and remedies if targets are missed. It should be measurable and unambiguous.

Related: Availability, Maintenance Window, Audit
Audit

An independent, documented examination of evidence to determine whether controls, records and practices meet stated requirements. Data centre audits may cover security, energy, operational processes or contractual compliance.

Related: Evidence, Compliance, Access Control
Compliance

The state of meeting applicable laws, regulations, standards and contractual obligations. It requires identifying requirements, implementing controls, keeping evidence and reviewing performance through internal checks and external audits.

Related: Audit, Evidence, Standard
Evidence

Documented or observable proof that a control is designed and operating as intended, such as logs, test records, training certificates or policies. Auditors rely on evidence rather than verbal assurance to reach conclusions.

Related: Audit, Compliance, Configuration Management
Standard

A published, consensus-based document that sets requirements, specifications or good practice, often maintained by a recognised body. Standards may be certifiable or guidance only, and adoption is usually voluntary unless referenced by contract or regulation.

Related: Compliance, Certification, Audit
Certification

Formal confirmation by an accredited body that an organisation, facility or individual meets a specified standard. It usually involves assessment against criteria and periodic surveillance to maintain validity.

Related: Standard, Audit, Compliance
Business Continuity Management

A management process that identifies critical activities and builds resilience so essential services can continue or recover during disruption. It covers business impact analysis, recovery plans, testing and regular review.

Related: Risk Assessment, Disaster Recovery, Incident Management
Disaster Recovery

The plans, facilities and technologies used to restore IT services and data after a major disruption. Recovery objectives for time and data loss are agreed in advance and validated through testing.

Related: Business Continuity Management, Recovery Time Objective, Risk Assessment
Recovery Time Objective

The maximum acceptable duration for restoring a service after disruption, agreed with the business. It drives the choice of standby sites, spare capacity and staffing needed to meet continuity commitments.

Related: Disaster Recovery, Business Continuity Management, Service Level Agreement
Risk Assessment

The process of identifying threats and vulnerabilities, estimating likelihood and impact, and prioritising treatment. Results guide controls, investment and acceptance decisions, and should be reviewed when conditions change.

Related: Risk Register, Single Point of Failure, Business Continuity Management
Risk Register

A controlled record of identified risks, their owners, ratings and planned treatments. It provides a live view of exposure and is a key artefact for governance meetings and audits.

Related: Risk Assessment, Governance, Evidence
Governance

The framework of roles, policies, decision rights and oversight that directs how a data centre is managed and held accountable. It ensures objectives are set, risks are owned and performance is reported to senior management.

Related: Risk Register, Compliance, Audit
Competence

The combination of training, qualification, experience and demonstrated performance that enables a person to carry out a task safely and correctly. It should be defined for each role and verified through records.

Related: Evidence, Governance, Change Management