FL HVAC study materials
FL HVAC study resources

FL HVAC flashcards

FL HVAC · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Gross margin formula
Gross margin equals sales minus direct job costs, divided by sales. It excludes overhead and measures how much each job contributes to covering fixed expenses.
Break-even sales
Break-even sales equal annual overhead divided by gross margin percentage; at that sales level the company covers all fixed costs with zero net profit.
Notice to Owner deadline
In Florida, a Notice to Owner must be served before first furnishing or within 45 days after first furnishing to preserve the supplier's or subcontractor's lien rights.
Markup versus margin
Markup is a percentage of cost, while margin is a percentage of selling price. A 25% markup equals a 20% margin on the same job.
State-certified contractor
A state-certified contractor holds a Florida license and may practice anywhere in the state; a registered contractor may work only in jurisdictions where locally registered.
Florida Product Approval
A system or method of construction approved by the Florida Building Commission for statewide use; Miami-Dade Notice of Acceptance applies in the high-velocity hurricane zone.
Notice of Commencement
A document the owner records before work begins that identifies the property, contractor, and lender; it protects the owner and lender against certain lien claims.
Final inspection
The building department inspection after completion that verifies code compliance before a certificate of occupancy or completion is issued.
Manual J
ACCA's room-by-room residential load calculation method; it accounts for envelope, infiltration, internal, and latent loads using design conditions.
Sensible heat ratio
The sensible load divided by the total load. It indicates how much of the cooling capacity removes heat versus moisture and guides coil selection.
Sensible airflow formula
CFM equals sensible BTU per hour divided by 1.08 times the temperature difference in degrees Fahrenheit for standard sea-level air.
Latent airflow formula
CFM equals latent BTU per hour divided by 0.68 times the humidity ratio difference in grains of moisture per pound of dry air.
Subcooling charging method
Measured as condensing saturation temperature minus liquid-line temperature; used to charge TXV systems to the manufacturer's target, typically 8–12°F.
Superheat charging method
Measured as suction-line temperature minus evaporating saturation temperature; used to charge fixed-orifice systems to the manufacturer's target.
Evacuation target
A vacuum of 500 microns or lower held for 15 minutes confirms that moisture and non-condensables have been removed from the refrigerant circuit.
Condensate trap purpose
The trap holds a water seal that offsets cabinet static pressure so condensate drains; without it, air is pulled in or blown out.
Manual D
ACCA's duct design method that uses available static pressure and total effective length to determine friction rate and size each duct run.
Equivalent length
The total effective length of a duct run including straight duct plus fitting allowances, expressed in feet, used to calculate friction rate.
Flex duct bend radius
Flex duct should be fully extended and bends kept at least 1.5 times the duct diameter to avoid excessive pressure drop.
Transfer grille
A grille or jumper duct that provides a return air path between a closed room and the return system, preventing room pressurization.
Superheat definition
Suction-line temperature minus the evaporating saturation temperature; it confirms that all liquid refrigerant has boiled off before the compressor.
Subcooling definition
Condensing saturation temperature minus liquid-line temperature; it confirms that liquid refrigerant fills the last part of the condenser.
Compression ratio
Discharge pressure in psia divided by suction pressure in psia; high ratios increase compressor heat and reduce capacity.
R-410A charging
R-410A is a near-azeotropic blend and must be charged as a liquid from the cylinder to prevent fractionation and incorrect composition.
Ohm's law
Voltage equals current times resistance (V = I × R); power in a resistive circuit equals voltage times current.
Capacitor discharge
Before testing, short the capacitor terminals through a resistor to remove stored voltage; capacitors can hold a lethal charge after power is removed.
Thermostat C wire
The common wire provides 24V power to the thermostat; without it, smart thermostats may need batteries or a power-stealing device.
MCA and MOP
Minimum circuit ampacity sizes the conductors; maximum overcurrent protection sizes the breaker, both taken from the equipment nameplate.
Recovery cylinder fill limit
A refrigerant recovery cylinder may be filled to no more than 80% of its water capacity by weight, leaving room for liquid expansion.
Lockout tagout
A procedure that isolates and locks electrical or other energy sources before service, with a tag identifying the worker and reason.
Fall protection threshold
OSHA requires fall protection when working at heights of 6 feet or more, including roofs, ladders, and elevated platforms.
Refrigerant frostbite protection
Liquid refrigerant boils at very low temperature and can freeze skin on contact; gloves and goggles are required when handling it.