HI Plumber study materials
HI Plumber study resources

HI Plumber study plan

HI Plumber · Give each week a clear focus.

8 weeks · About 6 hours per week

Week 1

Drainage, Waste, and Venting Systems & General Plumbing Knowledge and Safety

  • Map the full DWV layout of a two-story house from memory on blank paper, labeling every trap, fixture drain, soil stack, vent stack, and building drain connection point

  • Compute developed length, fall per foot, and required pipe diameter for at least six drain segments using the sizing tables, showing each step of the arithmetic

  • Distinguish between a vent stack, stack vent, individual vent, common vent, wet vent, and circuit vent by writing a one-sentence definition and a sketch for each

  • List the safety hazards of working in a trench and in a confined space, and state the required protective action for each hazard you list

Your checkpoint

A hand-drawn DWV isometric of a two-story house with all vents labeled, plus a one-page sizing worksheet showing six completed drain calculations and the table values used

Week 2

Drainage, Waste, and Venting Systems & General Plumbing Knowledge and Safety

  • Size and lay out a vent system for a bathroom group containing a water closet, lavatory, and bathtub/shower, verifying every trap arm against its maximum developed length and fall limits

  • Diagnose five written DWV failure scenarios (gurgling traps, sewer odor, slow drains, bubbling fixtures, backflow) and name the most likely venting or drainage cause for each

  • Describe the correct installation sequence for a below-floor sanitary tee, closet flange, and trap arm so the finished rough-in matches the required dimensions

  • Explain trap seal protection, including the role of the trap weir, the air gap under the fixture, and why an S-trap or an unvented trap arm is prohibited

Your checkpoint

A completed bathroom-group DWV rough-in plan with every trap arm length and fall checked against code limits, plus a written diagnosis of all five failure scenarios with the corrective action for each

Week 3

Water Supply and Distribution Systems & General Plumbing Knowledge and Safety

  • Calculate minimum fixture unit demand for a single-family dwelling and convert total fixture units to the required main supply pipe size using the demand tables

  • Determine the correct water service line size, meter size, and pressure-reducing valve requirement for a given street pressure and building height

  • Explain the difference between a direct and an indirect water supply system, and identify where backflow protection is required on a potable system

  • Demonstrate the safe procedure for pressure-testing a new water line, including test pressure, hold time, and how to isolate the test section

Your checkpoint

A water supply sizing worksheet for a single-family dwelling showing fixture units per fixture group, cumulative demand, selected pipe sizes for every branch and the main, and a pass/fail pressure-test record

Week 4

Water Supply and Distribution Systems & Plumbing Systems and Fixtures

  • Trace a cold and hot water distribution layout from the meter through the water heater to every fixture, marking every shutoff valve, check valve, and expansion tank location

  • Compare tank-type and tankless water heaters on recovery rate, venting requirements, and temperature-and-pressure relief valve discharge piping, and state the code requirement for each

  • Install-level detail: describe the correct rough-in heights and clearances for a lavatory, water closet, and shower valve so the finished fixtures fit without rework

  • Identify the causes of water hammer and thermal expansion in a closed system and specify the device that controls each

Your checkpoint

A complete supply layout drawing with all valves and devices labeled, plus a comparison table of tank versus tankless water heaters covering recovery, venting, and relief valve discharge requirements

Week 5

Plumbing Code and Regulations

  • Locate and read the sections of the plumbing code that govern fixture clearances, trap requirements, vent termination distances, and support spacing, and write down the exact section numbers you used

  • Compare the requirements for a plumbing permit, inspection stages, and final sign-off in a typical jurisdiction, and list the documents a permit application needs

  • Explain how a code change or local amendment can override a general rule, and give a concrete example of a local amendment you would verify before rough-in

  • Build a personal code index of the fifteen most testable code limits (distances, diameters, slopes, pressures) with the value and the source section for each

Your checkpoint

A personal code index card set or spreadsheet of at least fifteen numeric code limits, each with its value, the section number, and a one-line note on where it applies

Week 6

Plumbing Code and Regulations & Business Management and Project Estimation

  • Walk through a fictional residential job from permit application to final inspection, listing every inspection checkpoint and what the inspector will look at

  • Produce a takeoff for a bathroom remodel that lists every pipe, fitting, fixture, and valve by quantity and size, and price the material list at current local rates

  • Estimate labor hours for the bathroom rough-in and finish using a productivity rate you can justify, then build a total bid with overhead and profit added

  • Draft a change-order template and a short written scope of work that protects the contractor against scope creep

Your checkpoint

A complete bid package for a bathroom remodel containing the material takeoff with pricing, labor estimate, total bid with overhead and profit, and a one-page scope of work

Week 7

Plumbing Systems and Fixtures & Business Management and Project Estimation

  • Describe the installation and trim-out of at least six fixture types (water closet, lavatory, kitchen sink, tub/shower, floor drain, hose bibb) including the fittings and sealant each requires

  • Explain the function and failure symptoms of a pressure-reducing valve, backflow preventer, tempering valve, and floor drain trap primer

  • Build a project schedule for a two-bathroom rough-in and finish, sequencing trades and inspections so no inspection is missed

  • Calculate a break-even hourly rate from annual overhead, billable hours, and target profit, and apply it to a sample job

Your checkpoint

A fixture installation reference sheet covering six fixture types and their trim components, plus a one-page project schedule with inspection milestones and a break-even rate calculation

Week 8

General Plumbing Knowledge and Safety & Plumbing Systems and Fixtures & Drainage, Waste, and Venting Systems & Water Supply and Distribution Systems & Plumbing Code and Regulations & Business Management and Project Estimation

  • Take two full-length timed practice exams under test conditions and record your score by domain so weak areas are visible

  • Re-study only the two lowest-scoring domains, reworking the missed calculation types rather than rereading notes

  • Recite from memory the fifteen code limits from your week 5 index and the DWV and supply sizing steps without referring to notes

  • Review safety procedures for trenching, confined space, pressure testing, and soldering, and confirm you can state the required action for each hazard

Your checkpoint

A scored practice-exam log showing both exam results by domain, a list of the specific error types you corrected, and a final one-page summary sheet of formulas and code limits for exam-day review

Milestones

Week 2: Can size a bathroom-group DWV and every trap arm from memory, and correctly diagnose all five venting failure scenarios without notes

Week 4: Can compute fixture-unit demand, select every supply pipe size, and lay out hot and cold distribution with all valves and devices in the right places

Week 6: Can cite at least fifteen numeric code limits with section numbers and produce a complete, priced bid package for a bathroom remodel

Week 8: Scores at or above the passing target on two timed full-length practice exams, with no domain below 70 percent and all missed calculation types reworked