HKIE Professional Assessment - Biomedical Discipline key terms
HKIE Professional Assessment - Biomedical Discipline · Get comfortable with the vocabulary.
- Biocompatibility
- Related: ISO 10993, Cytotoxicity
The ability of a material or device to perform its intended function in contact with living tissue without causing unacceptable local or systemic harm, assessed through ISO 10993 biological evaluation tests.
- ISO 10993
- Related: Biocompatibility, Cytotoxicity
The international standard series governing biological evaluation of medical devices, specifying which tests (cytotoxicity, sensitisation, implantation and others) apply based on contact nature and duration.
- Cytotoxicity
- Related: Biocompatibility, ISO 10993
The degree to which a material or its extractables damages or kills cells, typically screened in vitro with mammalian cell cultures and graded by morphological or viability scoring.
- Stress shielding
- Related: Elastic modulus, Osseointegration
Reduction of mechanical load carried by bone when a stiffer implant shares the load, leading to bone resorption and loosening; a key reason implants use titanium or lower-modulus alloys.
- Elastic modulus
- Related: Stress shielding, Fatigue failure
The ratio of stress to strain in the linear region of a material's stress-strain curve, indicating stiffness; matching it to tissue reduces stress shielding and soft-tissue injury.
- Fatigue failure
- Related: Elastic modulus, Accelerated life testing
Fracture of a device after repeated cyclic loading below its ultimate strength, common in implants, catheters and instrument components subjected to millions of service cycles.
- Osseointegration
- Related: Stress shielding, Biocompatibility
Direct structural and functional bonding between living bone and an implant surface without intervening fibrous tissue, essential for dental implants and orthopaedic prostheses.
- Haemocompatibility
- Related: Biocompatibility, ISO 10993
The property of a blood-contacting material to avoid triggering thrombosis, haemolysis, complement activation or platelet consumption during its intended contact period.
- IEC 60601-1
- Related: Applied part, Patient leakage current, Essential performance
The core international safety standard for medical electrical equipment, covering means of protection, risk management, essential performance and classification by shock protection and applied part type.
- Applied part
- Related: IEC 60601-1, Patient leakage current
The part of medical electrical equipment that comes into physical contact with the patient to perform its function, classified as Type B, BF or CF by permitted leakage current.
- Patient leakage current
- Related: Applied part, IEC 60601-1, Microshock
Current flowing from an applied part through the patient to earth, limited by IEC 60601-1 according to applied part type and normal or single-fault condition.
- Microshock
- Related: Patient leakage current, Applied part
The risk of ventricular fibrillation from very small currents (tens of microamps) applied directly to the heart via intracardiac catheters, driving strict limits for Type CF applied parts.
- Essential performance
- Related: IEC 60601-1, Risk control measure
Performance of a clinical function by medical electrical equipment that, if lost or degraded beyond limits, creates unacceptable risk; must be defined and verified under IEC 60601-1.
- Risk control measure
- Related: ISO 14971, Residual risk, Essential performance
An action or design feature adopted to reduce risk, applied in the preferred order of inherent safety, protective measures, then information for safety, as required by ISO 14971.
- ISO 14971
- Related: Risk control measure, Residual risk, Hazard
The international standard for applying risk management to medical devices, covering hazard identification, risk estimation and evaluation, risk control, and monitoring of production and post-production information.
- Residual risk
- Related: ISO 14971, Risk control measure
The risk remaining after risk control measures have been applied, which must be evaluated against benefit and disclosed in accompanying information where it is judged acceptable.
- Hazard
- Related: ISO 14971, Use error, Residual risk
A potential source of harm, such as electrical energy, a software defect, a biological contaminant or a use error, distinguished in risk management from the harm it may cause.
- Use error
- Related: IEC 62366, Hazard
An act or omission by the user during interaction with a device that leads to a different result than intended, addressed through usability engineering rather than blaming the operator.
- IEC 62366
- Related: Use error, Formative evaluation
The standard for applying usability engineering to medical devices, requiring identification of use-related hazards and validation of the user interface through simulated use with representative users.
- Formative evaluation
- Related: IEC 62366, Use error
Iterative usability testing performed during design to identify interface problems and refine the device early, before the summative validation required by IEC 62366.
- ISO 13485
- Related: Design history file, CAPA, Medical Device Administrative Control System
The international quality management system standard specific to medical device organisations, requiring documented processes for design, production, traceability, complaint handling and regulatory reporting.
- CAPA
- Related: ISO 13485, Design history file
Corrective and preventive action: a closed-loop quality process for investigating root causes of nonconformities and implementing changes that prevent recurrence, recorded and verified for effectiveness.
- Design history file
- Related: ISO 13485, Verification and validation
A compilation of records describing the design history of a finished device, demonstrating that the design was developed in accordance with the approved design plan and quality system.
- Verification and validation
- Related: Design history file, Clinical evaluation
Two distinct confirmation activities: verification checks that design outputs meet specified requirements, while validation confirms that the device meets user needs in the intended clinical use environment.
- Clinical evaluation
- Related: Verification and validation, Post-market surveillance
The systematic appraisal of clinical data, including literature and own investigations, to demonstrate safety and performance of a device for its intended purpose throughout its lifecycle.
- Post-market surveillance
- Related: Vigilance reporting, Clinical evaluation, ISO 14971
The ongoing collection and analysis of real-world device performance data after release, including complaints, vigilance reports and field safety corrective actions, feeding back into risk management.
- Vigilance reporting
- Related: Post-market surveillance, Medical Device Administrative Control System
Mandatory notification to a regulator of incidents involving death, serious injury or serious public health risk associated with a device, within defined timelines after becoming aware.
- Medical Device Administrative Control System
- Related: Vigilance reporting, ISO 13485
Hong Kong's voluntary framework administered by the Medical Device Division, comprising listing of devices, traders and manufacturers plus post-market surveillance, pending a statutory regime.
- Clinical engineering
- Related: Acceptance testing, Planned preventive maintenance, Health technology assessment
The healthcare engineering discipline responsible for selecting, maintaining, calibrating and safely managing medical equipment, and advising clinical services on technology acquisition and use.
- Planned preventive maintenance
- Related: Calibration traceability, Acceptance testing, Mean time between failures
Scheduled inspection, testing and servicing of equipment at defined intervals to keep performance within specification and detect deterioration before it causes failure or harm.
- Calibration traceability
- Related: Measurement uncertainty, Planned preventive maintenance
An unbroken chain of comparisons linking a measurement made by a device to a national or international reference standard, each step having stated uncertainty.
- Measurement uncertainty
- Related: Calibration traceability, Acceptance testing
A quantified range around a measured value within which the true value is expected to lie, combining contributions from the instrument, operator, environment and reference standard.
- Acceptance testing
- Related: Clinical engineering, Planned preventive maintenance
Verification performed when new equipment arrives on site, confirming that it meets purchase specification and safety requirements before first clinical use and entry into the asset register.
- Mean time between failures
- Related: Planned preventive maintenance, Health technology assessment
The average operating time between successive failures of a repairable device, used in reliability modelling, maintenance planning and replacement decisions.
- Health technology assessment
- Related: Clinical engineering, Lifecycle cost
A multidisciplinary appraisal of the clinical effectiveness, safety, cost and organisational impact of a health technology, informing adoption, procurement and disinvestment decisions.
- Lifecycle cost
- Related: Health technology assessment, Mean time between failures
The total cost of ownership of equipment over its useful life, including acquisition, installation, consumables, maintenance, training, downtime and disposal.
- Common-mode rejection ratio
- Related: Signal-to-noise ratio, Electromagnetic compatibility
The ability of a differential amplifier to suppress a signal common to both inputs, such as mains interference, expressed as the ratio of differential gain to common-mode gain, usually in decibels.
- Signal-to-noise ratio
- Related: Common-mode rejection ratio, Anti-aliasing filter
The ratio of the power of a wanted physiological signal to the power of unwanted noise, often improved by averaging, filtering or shielding in biomedical acquisition systems.
- Anti-aliasing filter
- Related: Nyquist rate, Signal-to-noise ratio
An analogue low-pass filter placed before sampling to remove frequency content above half the sampling rate, preventing high-frequency components from folding back into the sampled signal.
- Nyquist rate
- Related: Anti-aliasing filter
The minimum sampling frequency, twice the highest frequency present in a signal, required to reconstruct the signal without aliasing.
- Electromagnetic compatibility
- Related: Common-mode rejection ratio, IEC 60601-1
The ability of equipment to operate in its electromagnetic environment without causing or suffering unacceptable disturbance, verified by emission and immunity tests under IEC 60601-1-2.
- DICOM
- Related: PACS, HL7 FHIR
The standard for exchanging medical images and associated information between scanners, workstations and archives, defining file format, network services and data element encoding.
- PACS
- Related: DICOM, HL7 FHIR
Picture archiving and communication system: the hospital infrastructure that stores, retrieves and displays medical images, interfacing with imaging modalities via DICOM and with records via HL7.
- HL7 FHIR
- Related: DICOM, Anonymisation
A modern healthcare interoperability standard using modular resources and web APIs to exchange clinical and administrative data between hospital systems and applications.
- Anonymisation
- Related: HL7 FHIR, PACS
Irreversible removal or transformation of identifying data so that a subject can no longer be re-identified, a prerequisite for secondary use of clinical data and images in research.
- Good manufacturing practice
- Related: Sterilisation validation, ISO 13485
The set of production and quality controls ensuring devices are consistently made to specification, covering facilities, documentation, process validation, sterilisation and release testing.
- Sterilisation validation
- Related: Good manufacturing practice, Biocompatibility
Demonstration with physical, chemical and biological indicators that a sterilisation process reliably achieves the required sterility assurance level throughout the product.
- Scaffold
- Related: Bioreactor, Good manufacturing practice
A three-dimensional temporary structure that supports cell attachment, proliferation and tissue formation, designed to degrade as new tissue replaces it.
- Bioreactor
- Related: Scaffold, Good manufacturing practice
A controlled culture system that supplies nutrients, oxygen and mechanical or electrical stimulation to growing tissue constructs, monitoring parameters to ensure reproducible quality.
- Advanced therapy medicinal product
- Related: Scaffold, Sterilisation validation
A medicinal product based on genes, cells or tissues, such as somatic cell therapies and tissue-engineered products, subject to dedicated regulatory pathways and manufacturing controls.
- Duty of care
- Related: Informed consent, Whistleblowing
The professional and legal obligation of an engineer to act in the safety and interests of patients and users, taking reasonable steps to prevent foreseeable harm.
- Informed consent
- Related: Duty of care, Anonymisation
Voluntary agreement by a competent person after receiving and understanding relevant information about risks, benefits and alternatives, essential in research and clinical interventions.
- Whistleblowing
- Related: Duty of care, Vigilance reporting
Reporting of unsafe, illegal or unethical practice through appropriate internal or external channels when normal routes fail, protected by professional codes and, in some jurisdictions, legislation.
- Conflict of interest
- Related: Duty of care, Health technology assessment
A situation where personal, financial or other interests could improperly influence professional judgement, requiring declaration and management to preserve trust and objectivity.
- Continuous professional development
- Related: Duty of care, Conflict of interest
Sustained, planned learning and reflective practice that maintains and enhances competence throughout a professional career, recorded to demonstrate fitness to practise.
- Circular economy
- Related: Lifecycle cost, Reprocessing of single-use devices
An economic model that keeps materials in use through reuse, repair, refurbishment and recycling, reducing waste from single-use devices, packaging and equipment disposal.
- Reprocessing of single-use devices
- Related: Circular economy, Sterilisation validation
Cleaning, disinfection or sterilisation and re-use of a device labelled single-use, permitted only with validated procedures, risk assessment and regulatory approval.
- Clinical evaluation
- Related: Verification and validation, Post-market surveillance
The systematic appraisal of clinical data, including literature and own investigations, to demonstrate safety and performance of a device for its intended purpose throughout its lifecycle.
- Accelerated life testing
- Related: Fatigue failure, Mean time between failures
Testing devices at elevated stress or cycling rates to estimate long-term reliability within a shorter period, with results extrapolated using an appropriate failure model.