HKIE Professional Assessment - Biomedical Discipline study materials
HKIE Professional Assessment - Biomedical Discipline study resources

HKIE Professional Assessment - Biomedical Discipline key terms

HKIE Professional Assessment - Biomedical Discipline · Get comfortable with the vocabulary.

Biocompatibility

The ability of a material or device to perform its intended function in contact with living tissue without causing unacceptable local or systemic harm, assessed through ISO 10993 biological evaluation tests.

Related: ISO 10993, Cytotoxicity
ISO 10993

The international standard series governing biological evaluation of medical devices, specifying which tests (cytotoxicity, sensitisation, implantation and others) apply based on contact nature and duration.

Related: Biocompatibility, Cytotoxicity
Cytotoxicity

The degree to which a material or its extractables damages or kills cells, typically screened in vitro with mammalian cell cultures and graded by morphological or viability scoring.

Related: Biocompatibility, ISO 10993
Stress shielding

Reduction of mechanical load carried by bone when a stiffer implant shares the load, leading to bone resorption and loosening; a key reason implants use titanium or lower-modulus alloys.

Related: Elastic modulus, Osseointegration
Elastic modulus

The ratio of stress to strain in the linear region of a material's stress-strain curve, indicating stiffness; matching it to tissue reduces stress shielding and soft-tissue injury.

Related: Stress shielding, Fatigue failure
Fatigue failure

Fracture of a device after repeated cyclic loading below its ultimate strength, common in implants, catheters and instrument components subjected to millions of service cycles.

Related: Elastic modulus, Accelerated life testing
Osseointegration

Direct structural and functional bonding between living bone and an implant surface without intervening fibrous tissue, essential for dental implants and orthopaedic prostheses.

Related: Stress shielding, Biocompatibility
Haemocompatibility

The property of a blood-contacting material to avoid triggering thrombosis, haemolysis, complement activation or platelet consumption during its intended contact period.

Related: Biocompatibility, ISO 10993
IEC 60601-1

The core international safety standard for medical electrical equipment, covering means of protection, risk management, essential performance and classification by shock protection and applied part type.

Related: Applied part, Patient leakage current, Essential performance
Applied part

The part of medical electrical equipment that comes into physical contact with the patient to perform its function, classified as Type B, BF or CF by permitted leakage current.

Related: IEC 60601-1, Patient leakage current
Patient leakage current

Current flowing from an applied part through the patient to earth, limited by IEC 60601-1 according to applied part type and normal or single-fault condition.

Related: Applied part, IEC 60601-1, Microshock
Microshock

The risk of ventricular fibrillation from very small currents (tens of microamps) applied directly to the heart via intracardiac catheters, driving strict limits for Type CF applied parts.

Related: Patient leakage current, Applied part
Essential performance

Performance of a clinical function by medical electrical equipment that, if lost or degraded beyond limits, creates unacceptable risk; must be defined and verified under IEC 60601-1.

Related: IEC 60601-1, Risk control measure
Risk control measure

An action or design feature adopted to reduce risk, applied in the preferred order of inherent safety, protective measures, then information for safety, as required by ISO 14971.

Related: ISO 14971, Residual risk, Essential performance
ISO 14971

The international standard for applying risk management to medical devices, covering hazard identification, risk estimation and evaluation, risk control, and monitoring of production and post-production information.

Related: Risk control measure, Residual risk, Hazard
Residual risk

The risk remaining after risk control measures have been applied, which must be evaluated against benefit and disclosed in accompanying information where it is judged acceptable.

Related: ISO 14971, Risk control measure
Hazard

A potential source of harm, such as electrical energy, a software defect, a biological contaminant or a use error, distinguished in risk management from the harm it may cause.

Related: ISO 14971, Use error, Residual risk
Use error

An act or omission by the user during interaction with a device that leads to a different result than intended, addressed through usability engineering rather than blaming the operator.

Related: IEC 62366, Hazard
IEC 62366

The standard for applying usability engineering to medical devices, requiring identification of use-related hazards and validation of the user interface through simulated use with representative users.

Related: Use error, Formative evaluation
Formative evaluation

Iterative usability testing performed during design to identify interface problems and refine the device early, before the summative validation required by IEC 62366.

Related: IEC 62366, Use error
ISO 13485

The international quality management system standard specific to medical device organisations, requiring documented processes for design, production, traceability, complaint handling and regulatory reporting.

Related: Design history file, CAPA, Medical Device Administrative Control System
CAPA

Corrective and preventive action: a closed-loop quality process for investigating root causes of nonconformities and implementing changes that prevent recurrence, recorded and verified for effectiveness.

Related: ISO 13485, Design history file
Design history file

A compilation of records describing the design history of a finished device, demonstrating that the design was developed in accordance with the approved design plan and quality system.

Related: ISO 13485, Verification and validation
Verification and validation

Two distinct confirmation activities: verification checks that design outputs meet specified requirements, while validation confirms that the device meets user needs in the intended clinical use environment.

Related: Design history file, Clinical evaluation
Clinical evaluation

The systematic appraisal of clinical data, including literature and own investigations, to demonstrate safety and performance of a device for its intended purpose throughout its lifecycle.

Related: Verification and validation, Post-market surveillance
Post-market surveillance

The ongoing collection and analysis of real-world device performance data after release, including complaints, vigilance reports and field safety corrective actions, feeding back into risk management.

Related: Vigilance reporting, Clinical evaluation, ISO 14971
Vigilance reporting

Mandatory notification to a regulator of incidents involving death, serious injury or serious public health risk associated with a device, within defined timelines after becoming aware.

Related: Post-market surveillance, Medical Device Administrative Control System
Medical Device Administrative Control System

Hong Kong's voluntary framework administered by the Medical Device Division, comprising listing of devices, traders and manufacturers plus post-market surveillance, pending a statutory regime.

Related: Vigilance reporting, ISO 13485
Clinical engineering

The healthcare engineering discipline responsible for selecting, maintaining, calibrating and safely managing medical equipment, and advising clinical services on technology acquisition and use.

Related: Acceptance testing, Planned preventive maintenance, Health technology assessment
Planned preventive maintenance

Scheduled inspection, testing and servicing of equipment at defined intervals to keep performance within specification and detect deterioration before it causes failure or harm.

Related: Calibration traceability, Acceptance testing, Mean time between failures
Calibration traceability

An unbroken chain of comparisons linking a measurement made by a device to a national or international reference standard, each step having stated uncertainty.

Related: Measurement uncertainty, Planned preventive maintenance
Measurement uncertainty

A quantified range around a measured value within which the true value is expected to lie, combining contributions from the instrument, operator, environment and reference standard.

Related: Calibration traceability, Acceptance testing
Acceptance testing

Verification performed when new equipment arrives on site, confirming that it meets purchase specification and safety requirements before first clinical use and entry into the asset register.

Related: Clinical engineering, Planned preventive maintenance
Mean time between failures

The average operating time between successive failures of a repairable device, used in reliability modelling, maintenance planning and replacement decisions.

Related: Planned preventive maintenance, Health technology assessment
Health technology assessment

A multidisciplinary appraisal of the clinical effectiveness, safety, cost and organisational impact of a health technology, informing adoption, procurement and disinvestment decisions.

Related: Clinical engineering, Lifecycle cost
Lifecycle cost

The total cost of ownership of equipment over its useful life, including acquisition, installation, consumables, maintenance, training, downtime and disposal.

Related: Health technology assessment, Mean time between failures
Common-mode rejection ratio

The ability of a differential amplifier to suppress a signal common to both inputs, such as mains interference, expressed as the ratio of differential gain to common-mode gain, usually in decibels.

Related: Signal-to-noise ratio, Electromagnetic compatibility
Signal-to-noise ratio

The ratio of the power of a wanted physiological signal to the power of unwanted noise, often improved by averaging, filtering or shielding in biomedical acquisition systems.

Related: Common-mode rejection ratio, Anti-aliasing filter
Anti-aliasing filter

An analogue low-pass filter placed before sampling to remove frequency content above half the sampling rate, preventing high-frequency components from folding back into the sampled signal.

Related: Nyquist rate, Signal-to-noise ratio
Nyquist rate

The minimum sampling frequency, twice the highest frequency present in a signal, required to reconstruct the signal without aliasing.

Related: Anti-aliasing filter
Electromagnetic compatibility

The ability of equipment to operate in its electromagnetic environment without causing or suffering unacceptable disturbance, verified by emission and immunity tests under IEC 60601-1-2.

Related: Common-mode rejection ratio, IEC 60601-1
DICOM

The standard for exchanging medical images and associated information between scanners, workstations and archives, defining file format, network services and data element encoding.

Related: PACS, HL7 FHIR
PACS

Picture archiving and communication system: the hospital infrastructure that stores, retrieves and displays medical images, interfacing with imaging modalities via DICOM and with records via HL7.

Related: DICOM, HL7 FHIR
HL7 FHIR

A modern healthcare interoperability standard using modular resources and web APIs to exchange clinical and administrative data between hospital systems and applications.

Related: DICOM, Anonymisation
Anonymisation

Irreversible removal or transformation of identifying data so that a subject can no longer be re-identified, a prerequisite for secondary use of clinical data and images in research.

Related: HL7 FHIR, PACS
Good manufacturing practice

The set of production and quality controls ensuring devices are consistently made to specification, covering facilities, documentation, process validation, sterilisation and release testing.

Related: Sterilisation validation, ISO 13485
Sterilisation validation

Demonstration with physical, chemical and biological indicators that a sterilisation process reliably achieves the required sterility assurance level throughout the product.

Related: Good manufacturing practice, Biocompatibility
Scaffold

A three-dimensional temporary structure that supports cell attachment, proliferation and tissue formation, designed to degrade as new tissue replaces it.

Related: Bioreactor, Good manufacturing practice
Bioreactor

A controlled culture system that supplies nutrients, oxygen and mechanical or electrical stimulation to growing tissue constructs, monitoring parameters to ensure reproducible quality.

Related: Scaffold, Good manufacturing practice
Advanced therapy medicinal product

A medicinal product based on genes, cells or tissues, such as somatic cell therapies and tissue-engineered products, subject to dedicated regulatory pathways and manufacturing controls.

Related: Scaffold, Sterilisation validation
Duty of care

The professional and legal obligation of an engineer to act in the safety and interests of patients and users, taking reasonable steps to prevent foreseeable harm.

Related: Informed consent, Whistleblowing
Informed consent

Voluntary agreement by a competent person after receiving and understanding relevant information about risks, benefits and alternatives, essential in research and clinical interventions.

Related: Duty of care, Anonymisation
Whistleblowing

Reporting of unsafe, illegal or unethical practice through appropriate internal or external channels when normal routes fail, protected by professional codes and, in some jurisdictions, legislation.

Related: Duty of care, Vigilance reporting
Conflict of interest

A situation where personal, financial or other interests could improperly influence professional judgement, requiring declaration and management to preserve trust and objectivity.

Related: Duty of care, Health technology assessment
Continuous professional development

Sustained, planned learning and reflective practice that maintains and enhances competence throughout a professional career, recorded to demonstrate fitness to practise.

Related: Duty of care, Conflict of interest
Circular economy

An economic model that keeps materials in use through reuse, repair, refurbishment and recycling, reducing waste from single-use devices, packaging and equipment disposal.

Related: Lifecycle cost, Reprocessing of single-use devices
Reprocessing of single-use devices

Cleaning, disinfection or sterilisation and re-use of a device labelled single-use, permitted only with validated procedures, risk assessment and regulatory approval.

Related: Circular economy, Sterilisation validation
Clinical evaluation

The systematic appraisal of clinical data, including literature and own investigations, to demonstrate safety and performance of a device for its intended purpose throughout its lifecycle.

Related: Verification and validation, Post-market surveillance
Accelerated life testing

Testing devices at elevated stress or cycling rates to estimate long-term reliability within a shorter period, with results extrapolated using an appropriate failure model.

Related: Fatigue failure, Mean time between failures