HVAC Excellence Master LC-AC · Get comfortable with the vocabulary.

sensible heat

Heat that changes the temperature of a substance without changing its state. In air conditioning it is the portion of the total load that a thermometer can measure directly.

Related: latent heat, total heat
latent heat

Heat absorbed or released when a substance changes state at constant temperature, such as water evaporating or refrigerant boiling. It is not visible on a dry-bulb thermometer.

Related: sensible heat, enthalpy
dry-bulb temperature

The ordinary air temperature measured by a dry thermometer. It is the value reported in weather forecasts and used to set room thermostats.

Related: wet-bulb temperature, relative humidity
wet-bulb temperature

The lowest temperature reachable by evaporating water into air, measured with a wetted thermometer in moving air. It indicates how much moisture the air can still absorb.

Related: dry-bulb temperature, relative humidity
relative humidity

The percentage of moisture the air currently holds compared with the maximum it could hold at that temperature. Warmer air can hold more water vapor.

Related: dew point, wet-bulb temperature
dew point

The temperature at which air becomes saturated and water vapor begins to condense. A coil operating below dew point removes moisture from the airstream.

Related: relative humidity, latent heat
enthalpy

The total heat content of air, combining sensible and latent energy per pound of dry air. Technicians use it to compare the energy of air entering and leaving a coil.

Related: sensible heat, latent heat
superheat

The temperature of refrigerant vapor above its saturation temperature at the same pressure. Measured at the evaporator outlet, it confirms the coil is fully fed with liquid.

Related: subcooling, saturation temperature
subcooling

The temperature of liquid refrigerant below its saturation temperature at the same pressure. Measured at the condenser outlet, it confirms the coil is fully condensing and feeding a solid liquid column.

Related: superheat, saturation temperature
saturation temperature

The temperature at which a refrigerant boils or condenses at a given pressure. On a pressure-temperature chart it is the temperature read directly from the measured pressure.

Related: superheat, subcooling
pressure-temperature chart

A chart or app that converts refrigerant pressure to saturation temperature for a specific refrigerant. It is the basis for calculating superheat and subcooling in the field.

Related: saturation temperature, superheat
refrigerant glide

The temperature difference between the bubble point and dew point of a zeotropic refrigerant blend as it changes state. Glide affects how superheat and subcooling are calculated.

Related: saturation temperature, superheat
compressor

The pump that raises refrigerant pressure and moves vapor through the system. It creates the pressure difference that allows the evaporator to absorb heat and the condenser to reject it.

Related: condenser, evaporator
evaporator

The indoor coil where low-pressure liquid refrigerant boils and absorbs heat from the airstream. It removes both sensible heat and latent heat from the conditioned space.

Related: condenser, superheat
condenser

The outdoor coil where high-pressure refrigerant vapor rejects heat and condenses to liquid. It discharges both the heat absorbed indoors and the heat of compression.

Related: evaporator, subcooling
metering device

A valve or fixed orifice that drops refrigerant pressure and regulates flow into the evaporator. Common types include thermostatic expansion valves, electronic expansion valves, and pistons.

Related: superheat, evaporator
thermostatic expansion valve

A modulating metering device that controls refrigerant flow to maintain a set superheat at the evaporator outlet. It responds to bulb temperature and evaporator pressure.

Related: superheat, metering device
airflow

The volume of air moved through a system per unit time, usually stated in cubic feet per minute. Low airflow causes low capacity, high superheat, and possible coil icing.

Related: static pressure, evaporator
static pressure

The resistance to airflow in a duct system, measured in inches of water column. High static pressure reduces airflow and raises blower load.

Related: airflow, blower
temperature split

The difference between return-air and supply-air temperatures across an operating system. It is a quick field check of capacity, airflow, and charge.

Related: airflow, superheat
combustion air

Air supplied to a burner for complete fuel combustion. Inadequate combustion air produces carbon monoxide and poor flame quality.

Related: excess air, carbon monoxide
excess air

Air supplied beyond the theoretical amount needed for complete combustion, usually expressed as a percentage. Proper excess air balances safety against stack loss.

Related: combustion air, carbon monoxide
carbon monoxide

A colorless, odorless gas produced by incomplete combustion. It is a health hazard and must be tested in flue gas and ambient air during service.

Related: combustion air, flame rectification
flame rectification

A flame-sensing method in which the burner flame conducts current in one direction between a sensing rod and ground. The control module proves flame before allowing gas flow.

Related: ignition sequence, thermocouple
thermocouple

A device made of two dissimilar metals that generates a small voltage when heated. In standing-pilot systems it holds the gas valve open while flame is present.

Related: flame rectification, ignition sequence
ignition sequence

The timed series of steps a furnace control follows before and during burner operation, including inducer start, pressure switch proof, ignition, and flame proving.

Related: flame rectification, pressure switch
pressure switch

A safety device that proves the inducer is moving combustion air before the gas valve opens. It opens or closes on a set pressure difference.

Related: ignition sequence, combustion air
heat anticipator

A small heater in a mechanical thermostat that warms the bimetal slightly near setpoint to end the heating cycle early and reduce overshoot.

Related: thermostat, deadband
deadband

The range of temperature around setpoint in which no heating or cooling is called. It prevents short cycling and is adjustable on many digital controls.

Related: thermostat, heat anticipator
thermostat

A control that senses space temperature and switches heating or cooling equipment to hold a setpoint. Modern versions add scheduling, staging, and remote sensing.

Related: deadband, heat anticipator
contactor

An electrically operated switch that uses a coil to close heavy power contacts for a compressor or other large load. The coil is controlled by low-voltage circuitry.

Related: relay, overload
overload

A protective device that opens a circuit when current or temperature exceeds a safe limit, preventing motor damage. It may reset automatically or require manual reset.

Related: contactor, locked rotor amps
locked rotor amps

The current a motor draws when the rotor cannot turn. Comparing it with running current helps diagnose seized compressors and starting problems.

Related: overload, capacitor
capacitor

A component that stores electrical energy and shifts phase to help start or run a motor. A failed capacitor causes high current draw and poor motor performance.

Related: locked rotor amps, contactor
superheat charging method

Setting refrigerant charge in a fixed-orifice or piston system by measuring evaporator outlet superheat against the manufacturer's target for current conditions.

Related: superheat, subcooling
subcooling charging method

Setting refrigerant charge in a thermostatic expansion valve system by measuring condenser outlet subcooling against the manufacturer's target.

Related: subcooling, thermostatic expansion valve
recovery

Removing refrigerant from a system into a container for reuse, recycling, or disposal. It is legally required before opening a circuit and protects the atmosphere.

Related: refrigerant glide, compressor
blower

The fan that moves air through the ductwork and across the indoor coil or heat exchanger. Its speed is set to match required airflow for the installed equipment.

Related: airflow, static pressure