Code Administration and Scope of the International Codes

  • IBC Chapter 1 establishes administration for permits, construction documents, inspections, certificates of occupancy, and boards of appeals.

  • The code applies to construction, alteration, enlargement, repair, movement, demolition, and changes of use or occupancy of buildings and structures.

  • A permit is required before construction, alteration, or demolition; ordinary repairs and minor work listed in Section 105.2 are exempt.

  • Construction documents must be sufficiently detailed to show compliance, including plans, elevations, sections, structural details, and MEP information.

  • A certificate of occupancy is required before a building may be used for its intended purpose; a temporary certificate may authorize partial occupancy.

  • Alterations, additions, and changes of occupancy in existing buildings must comply with the International Existing Building Code as referenced.

  • Referenced standards adopted in IBC Chapter 35 are enforceable as part of the code.

  • In flood hazard areas, permits require elevation, floodproofing, and anchoring documentation sufficient to show compliance with flood provisions.

Quick reference

Building Planning

  • Occupant load is the greater of the value computed from IBC Table 1004.5 floor area allowances or the actual number of occupants.

  • Allowable building height and area come from Tables 504.3, 504.4, and 506.2, with frontage increases calculated under Section 506.3.

  • Mixed occupancies may be designed as separated occupancies under Section 508.4 or nonseparated occupancies under Section 508.3.

  • Accessory occupancies are limited by area and must be ancillary to the principal occupancy; hazardous uses are restricted.

  • Exterior wall fire separation distance determines required wall fire-resistance ratings and limits on unprotected openings.

  • Guards are required at open-sided surfaces more than 30 inches above the floor or grade below and must be at least 42 inches high.

  • Sanitary facilities must be provided in the quantities and types required by the code and the International Plumbing Code.

Quick reference

Occupancy Classification and Construction Types

  • The IBC classifies buildings by use into Groups A, B, E, F, H, I, M, R, S, and U.

  • Construction Types I through IV have A and B subtypes with different fire-resistance requirements; Type V is the least restrictive.

  • Type I-A generally uses a 3-hour structural frame; Type V-B has an unprotected structural frame.

  • A high-rise building has an occupied floor more than 75 feet above the lowest level of fire department vehicle access.

  • Incidental uses listed in Table 509 must be separated from or protected relative to the main occupancy as specified.

  • Group H occupancy classification depends on the type and quantity of hazardous materials present.

  • Allowable height and area depend on occupancy group, construction type, sprinkler protection, and frontage.

Quick reference

Fire and Smoke Protection Features

  • Fire-resistance ratings are established by tested assemblies such as ASTM E119 or UL 263.

  • Fire barriers, fire partitions, and smoke barriers must be continuous through concealed spaces to maintain their required rating.

  • Opening protectives in rated walls require fire doors and fire windows rated according to IBC Table 716.1(2).

  • Penetrations and joints in rated assemblies must be protected with approved materials and systems under Chapter 7.

  • Shaft enclosures are required for vertical openings, subject to exceptions such as atriums and certain open parking structures.

  • Smoke barriers create smoke compartments; institutional occupancies require refuge areas of at least 30 net square feet per occupant unless excepted.

  • Fire dampers are required where ducts penetrate fire-resistance-rated assemblies, except where specific code exceptions apply.

  • Draftstopping is required in combustible concealed spaces to limit the spread of fire and smoke.

Quick reference

Means of Egress and Accessibility

  • A means of egress consists of exit access, the exit, and exit discharge, forming a continuous path to the public way.

  • Egress width is determined from IBC Table 1005.3.2; unsprinklered stairways use 0.2 inch per occupant and other components use 0.15 inch per occupant.

  • Travel distance is measured along the natural path of travel and is limited by occupancy and sprinkler status.

  • Two exits are required where occupant load, common path, or travel distance exceeds the limits for a single exit.

  • Exit signs and means-of-egress illumination are required, and emergency illumination must be provided for 90 minutes.

  • Doors in a means of egress must provide a clear width of at least 32 inches, and accessible routes must be at least 36 inches wide.

  • Accessible ramps may not exceed a 1:12 slope and must have landings at the top and bottom.

  • Handrails must be 34 to 38 inches above the walking surface, and guards must be at least 42 inches high.

Quick reference

Structural Design

  • Structural loads and load combinations are determined under IBC Chapter 16 and ASCE 7.

  • Buildings are assigned Risk Categories I through IV based on occupancy and consequences of failure.

  • Seismic design category A through F is determined from mapped spectral accelerations, site class, and risk category.

  • Wind design uses basic wind speed maps and exposure categories B, C, or D based on surface roughness.

  • Live load reduction is permitted only where allowed by ASCE 7 and the member supports sufficient tributary area.

  • Deflection limits for structural members are specified in IBC Table 1604.3.

  • Special inspections and structural tests are required under IBC Chapter 17 where specified by the statement of special inspections.

  • Foundation design requires a geotechnical report or approved soil bearing values where required by the code.

Quick reference

Materials and Foundations

  • Structural concrete is designed under ACI 318, masonry under TMS 402/602, structural steel under AISC 360/341, and wood under the NDS.

  • Footings must extend below the frost line or be designed to prevent frost heave.

  • Foundation design uses allowable bearing pressure from a geotechnical report or approved presumptive values.

  • Minimum concrete cover depends on member exposure, concrete strength, and whether the member is cast against earth.

  • Foundation walls below grade require dampproofing or waterproofing based on soil and groundwater conditions.

  • Termite protection is required in areas subject to termite infestation, using approved methods and materials.

  • Anchor bolts, connectors, and foundation anchorage must be designed and installed to resist applicable loads.

Quick reference

Building Envelope

  • The building envelope separates interior and exterior environments and controls heat, air, and moisture movement.

  • Wall assemblies require flashing, weep holes, and a drainage plane to direct water out of the assembly.

  • Roof coverings are classified A, B, or C for resistance to external fire exposure, with Class A being the highest.

  • Vapor retarder location depends on climate and assembly design so that moisture is not trapped within the envelope.

  • Combustible exterior cladding is limited by Chapter 14 and may require NFPA 285 testing for multistory applications.

  • Fenestration must meet the U-factor and solar heat gain coefficient requirements of the applicable energy code.

  • Air leakage through the building envelope must be limited in accordance with the energy code and envelope requirements.

Quick reference

Energy Efficiency

  • The International Energy Conservation Code governs energy efficiency for residential and commercial buildings.

  • Climate zones 0 through 8 are based on heating and cooling degree days, and envelope requirements vary by zone.

  • Compliance may be shown through prescriptive, trade-off, or performance paths.

  • Continuous insulation and assembly U-factor requirements are specified in the IECC tables for each climate zone.

  • Economizers are required for certain cooling systems based on climate zone, capacity, and exceptions.

  • Lighting controls include occupancy sensors, time switches, and daylight controls where required by the energy code.

  • Air barrier and commissioning requirements apply to envelope, mechanical, and lighting systems as specified.

Quick reference

Mechanical and Plumbing Provisions

  • The International Mechanical Code governs HVAC, exhaust, and ventilation; the International Plumbing Code governs plumbing systems.

  • Minimum outdoor air ventilation rates are specified in IMC Table 403.3.1.1 by occupancy.

  • Bathrooms and other rooms with contaminants require mechanical exhaust in accordance with the IMC.

  • Plumbing fixtures must be provided in the quantities required by IPC Table 403.1 and connected through fixture-unit sizing.

  • Each plumbing trap must maintain a water seal of at least 2 inches and not more than 4 inches.

  • Water heaters require a temperature-and-pressure relief valve with a discharge pipe installed to the code.

  • Fuel-burning appliances require combustion air and venting in accordance with the IMC and International Fuel Gas Code.

  • Duct penetrations of fire-resistance-rated assemblies require approved dampers and protection under the IBC and IMC.