ICC 21 flashcards
ICC 21 · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Permit application contents
- A permit application must include construction documents, a site plan, and information showing compliance with the International Building Code, including occupant load and construction type where applicable.
- Certificate of occupancy
- Issued after inspection confirms the building complies with the permit and code; it authorizes the stated use and occupancy before the building may be occupied.
- Referenced standards
- Standards adopted by reference in IBC Chapter 35, such as ASTM, AISC, ACI, and NFPA documents, are enforceable as requirements of the code.
- Occupant load calculation
- The occupant load is the greater of the number computed using Table 1004.5 floor area allowances or the actual number of occupants, and it establishes egress requirements.
- Frontage increase
- Allowable building area may be increased where the building has open frontage on public ways or yards, calculated under IBC Section 506.3 using frontage length and open space width.
- Guard height
- Guards are required at open-sided walking surfaces more than 30 inches above the floor or grade below and must be at least 42 inches high.
- Occupancy groups
- The IBC classifies buildings by use into Groups A, B, E, F, H, I, M, R, S, and U, which control allowable height, area, and fire protection.
- Construction types
- Types I through IV have A and B subtypes with varying fire-resistance; Type V is wood or other combustible construction, with Type V-A protected and V-B unprotected.
- High-rise building
- A building with an occupied floor more than 75 feet above the lowest level of fire department vehicle access, triggering additional fire protection and egress requirements.
- Fire barrier continuity
- A fire barrier must be continuous from the floor slab to the underside of the floor or roof above, and through concealed spaces, to maintain its required fire-resistance rating.
- Opening protective rating
- Fire doors and fire windows installed in rated walls must have a fire protection rating determined from IBC Table 716.1(2) based on the wall rating and opening size.
- Smoke compartment refuge area
- In institutional occupancies, smoke compartments must provide a refuge area of at least 30 net square feet per occupant, unless the sprinklered building meets exceptions.
- Means of egress components
- A means of egress consists of exit access, the exit, and exit discharge, forming a continuous unobstructed path from any point in the building to the public way.
- Egress width factor
- Required egress capacity is calculated using IBC Table 1005.3.2; unsprinklered stairways use 0.2 inch per occupant, and other egress components use 0.15 inch per occupant.
- Accessible route width
- An accessible route must be at least 36 inches clear width, with passing spaces and turning spaces provided where required by ICC A117.1.
- Ramp slope limit
- Accessible ramps may not exceed a 1:12 slope, must have landings at top and bottom, and require handrails where the rise exceeds 6 inches.
- Risk category
- Buildings are assigned Risk Categories I through IV based on occupancy and consequences of failure; higher categories increase wind, snow, and seismic design loads.
- Seismic design category
- The seismic design category ranges from A to F and is determined from mapped spectral accelerations, site class, and risk category under ASCE 7.
- Deflection limits
- IBC Table 1604.3 sets maximum allowable deflections for structural members under dead, live, and wind loads to control cracking and serviceability.
- Concrete design standard
- Structural concrete must be designed and constructed in accordance with ACI 318, as referenced by IBC Chapter 19, including strength, durability, and detailing requirements.
- Frost depth footing
- Footings must extend below the frost line or be designed to prevent frost heave, using local frost depth data or an engineered foundation design.
- Allowable bearing pressure
- Foundation design uses the allowable soil bearing pressure established by a geotechnical report or approved presumptive values from IBC Table 1806.2.
- Roof fire classification
- Roof coverings are classified A, B, or C for fire resistance to external fire exposure, with Class A providing the highest level of protection.
- Wall flashing function
- Flashing directs water away from wall assemblies at roofs, windows, and penetrations, and weep holes allow drainage from the wall cavity.
- Vapor retarder placement
- A vapor retarder limits moisture diffusion through the building envelope; its location depends on climate, and it must not trap moisture inside the assembly.
- Climate zone
- The IECC divides the United States into climate zones 0 through 8 based on heating and cooling degree days, and envelope requirements vary by zone.
- Energy compliance paths
- The IECC permits prescriptive, trade-off, or performance compliance paths, each demonstrating that the proposed building meets the required energy efficiency level.
- Economizer requirement
- Mechanical cooling systems must include an economizer where required by the IECC based on climate zone, system capacity, and exceptions for space conditioning.
- Outdoor air ventilation
- The International Mechanical Code Table 403.3.1.1 specifies minimum outdoor air rates per person and per square foot for various occupancies.
- Trap seal depth
- A plumbing trap must maintain a water seal of at least 2 inches and not more than 4 inches to prevent sewer gas from entering the building.
- Fixture unit
- A fixture unit is a measure of the probable drainage load of a plumbing fixture, used with the International Plumbing Code to size drain and vent piping.
- Combustion air supply
- Fuel-burning appliances require combustion air from indoors or outdoors in accordance with the International Mechanical Code and International Fuel Gas Code.