ICC 21 key terms
ICC 21 · Get comfortable with the vocabulary.
- Code official
- Related: Permit, Certificate of occupancy
The appointed authority responsible for enforcing the code, reviewing submittals, issuing permits, conducting inspections, and approving or disapproving work under the adopted code.
- Permit
- Related: Code official, Certificate of occupancy
Written authorization from the code official allowing specified construction, alteration, or repair work to proceed, subject to plan review, inspections, and code compliance.
- Board of appeals
- Related: Code official
A local body authorized to hear appeals of code official decisions and grant limited interpretations or variances allowed by the adopted administrative provisions.
- Certificate of occupancy
- Related: Permit, Occupancy classification
A document issued by the code official confirming that a building or portion has been inspected and meets code requirements for the stated occupancy before use or occupancy.
- Building height
- Related: Grade plane, Allowable area
The vertical distance measured from the grade plane to the average height of the highest roof surface, used with occupancy and construction type to regulate allowable size.
- Grade plane
- Related: Building height
A reference plane representing the average finished ground level adjoining the building at exterior walls, used for measuring building height and story count.
- Fire separation distance
- Related: Building height, Fire-resistance rating
The distance measured horizontally from the building exterior wall to the lot line, centerline of a street, or other building on the same lot, used to limit exterior fire spread.
- Allowable area
- Related: Building height, Fire separation distance
The maximum floor area permitted for a building or story based on occupancy, construction type, sprinkler protection, and frontage, as determined by code area tables and adjustments.
- Occupancy classification
- Related: Assembly occupancy, Mixed occupancy
The category assigned to a building or space according to its use, such as assembly, business, educational, factory, mercantile, residential, storage, or utility, which sets applicable code requirements.
- Assembly occupancy
- Related: Occupancy classification, Means of egress
An occupancy used for gathering people for civic, social, religious, recreational, or similar purposes, where occupant load and egress features receive particular attention.
- Type I construction
- Related: Fire-resistance rating, Occupancy classification
The most fire-resistive construction type, with structural elements generally of noncombustible materials and high fire-resistance ratings intended for tall or large buildings.
- Mixed occupancy
- Related: Occupancy classification, Fire barrier
A building containing two or more occupancy classifications, where separations or other protections may be required and allowable area is determined by code rules.
- Fire-resistance rating
- Related: Fire barrier, Fire partition, Opening protective
The time in hours or minutes a building element resists fire exposure under standardized test conditions, as required by code tables and used to protect structural frames, walls, and openings.
- Fire barrier
- Related: Fire partition, Fire-resistance rating
A fire-resistance-rated wall or assembly designed to restrict fire spread, often required to be continuous from foundation to roof or floor, with protected openings and smoke sealing where specified.
- Fire partition
- Related: Fire barrier, Smoke barrier
A fire-resistance-rated wall assembly used to separate dwelling units, guest rooms, or corridors, generally with lower continuity requirements than a fire barrier.
- Smoke barrier
- Related: Fire partition, Means of egress
A continuous membrane, wall, or assembly designed to resist the movement of smoke, often used to protect exits, corridors, or areas of refuge.
- Opening protective
- Related: Fire barrier, Fire-resistance rating
A fire-rated assembly such as a door, shutter, window, or fire damper installed in an opening to maintain the fire-resistance rating of the surrounding wall or floor.
- Means of egress
- Related: Exit access, Exit discharge
A continuous and unobstructed path of travel from any point in a building to a public way, consisting of exit access, exit, and exit discharge.
- Exit access
- Related: Means of egress, Travel distance
The portion of a means of egress that leads from the occupied space to an exit, including aisles, corridors, and intervening rooms, but not the exit itself.
- Exit
- Related: Exit access, Exit discharge
The portion of a means of egress separated from other spaces by fire-resistance-rated construction, such as an exit stairway or exit passageway, that provides protected travel to the exit discharge.
- Exit discharge
- Related: Exit, Means of egress
The portion of a means of egress between the termination of an exit and a public way, such as an exterior door, yard, or walkway.
- Travel distance
- Related: Exit access, Means of egress
The measured distance along the path of egress travel from the most remote point in a space or story to an exit or other permitted point, limited by occupancy and construction.
- Dead load
- Related: Live load
The permanent vertical load from the weight of building materials, fixed equipment, and other permanently installed components that remain in place throughout the structure's life.
- Live load
- Related: Dead load
The variable load produced by occupants, furniture, movable equipment, and similar temporary uses, determined from code load tables for the occupancy or function.
- Wind load
- Related: Building height
The lateral force from wind pressure on a structure's surfaces and components, determined using code criteria that account for wind speed, exposure, height, and building shape.
- Foundation
- Related: Footing, Soil bearing capacity
The structural system that transfers building loads to the supporting soil or rock, including footings, piles, piers, and slabs, designed to limit settlement and provide stability.
- Footing
- Related: Foundation, Soil bearing capacity
The widened base of a foundation element that distributes concentrated building loads over a larger soil area to keep bearing pressures within allowable limits.
- Soil bearing capacity
- Related: Foundation, Footing
The maximum allowable pressure that soil can support beneath a foundation without excessive settlement or shear failure, determined by testing or code-prescribed values.
- Building envelope
- Related: Water-resistive barrier, Thermal envelope
The exterior enclosure of a building, including walls, roof, windows, doors, and foundation walls, that separates conditioned interior space from the outdoors and controls heat, air, and moisture flow.
- Water-resistive barrier
- Related: Building envelope, Vapor retarder
A material or assembly behind exterior cladding that resists water penetration into wall assemblies while allowing drainage and, when required, vapor movement.
- Vapor retarder
- Related: Water-resistive barrier, Building envelope
A material or layer installed to limit diffusion of water vapor through building assemblies, helping control condensation and moisture accumulation within walls, roofs, or floors.
- Thermal envelope
- Related: R-value, U-factor, Building envelope
The building envelope elements that enclose conditioned space, including insulation, windows, doors, and air sealing, and that are regulated for energy efficiency.
- R-value
- Related: U-factor, Thermal envelope
A measure of thermal resistance; higher values indicate greater resistance to heat flow and are used to specify insulation and assembly performance in energy code compliance.
- U-factor
- Related: R-value, Thermal envelope
The overall coefficient of heat transfer through an assembly, expressed in Btu/(h·ft²·°F); lower values indicate better thermal performance.
- Plumbing fixture
- Related: Trap seal
A receptacle or device that receives water, waste, or both and discharges into a drainage system, such as a sink, water closet, or floor drain.
- Trap seal
- Related: Plumbing fixture
The water retained in a plumbing trap that prevents sewer gas from entering a building while permitting wastewater to flow through the drainage system.
- Combustion air
Air supplied to fuel-burning appliances for proper combustion and venting, required to be provided in adequate quantity and from permitted sources.