ICC R5 study materials
ICC R5 study resources

ICC R5 cheat sheet

ICC R5 · Keep the key ideas within reach.

Quick reference

General Requirements and Administration

  • Scope: the IRC governs detached one- and two-family dwellings and townhouses not more than three stories above grade plane with a separate means of egress, plus accessory structures.

  • Chapter 1 assigns duties: the building official enforces the code; the permit applicant is responsible for compliance of the submitted construction documents.

  • Permits are required for new construction, additions, alterations, and most structural, electrical, mechanical, and plumbing work; ordinary repairs and listed minor work are exempt.

  • Construction documents must show the extent and character of the work, and must be prepared and sealed by a registered design professional where the law requires.

  • Inspections required before concealment include foundation, framing, and rough-in; work may not be covered until inspected and approved.

  • A certificate of occupancy is issued only after the completed work is inspected and found to comply with the approved documents.

  • Board of appeals: an appeal of an official's interpretation is filed within the time stated in the local ordinance, and filing an appeal stays enforcement unless the official certifies immediate hazard.

  • Validity: a permit lapses if work does not commence within 180 days (or the locally adopted period) or is suspended or abandoned for 180 days.

Quick reference

Building Planning and Foundations

  • Light, ventilation, and occupancy: every habitable room needs aggregate glazing area of at least 8 percent of floor area and openable area of at least 4 percent.

  • Ceiling height: habitable rooms, halls, and corridors require not less than 7 ft (2134 mm) clear; bathrooms, toilet rooms, and laundry rooms require 6 ft 8 in.

  • Egress: a dwelling unit must have at least one exit door, and every sleeping room must have at least one operable emergency escape and rescue opening.

  • Emergency escape opening sill height is not more than 44 in. above the floor; net clear opening is at least 5.7 sq ft (5.0 sq ft for grade-floor openings) with minimum width 20 in. and height 24 in.

  • Foundation footings: minimum width 12 in. and minimum thickness 6 in., bearing on undisturbed soil below the frost line; footing projections beyond the face of the wall are limited by table.

  • Frost-protected shallow foundations use a minimum footing depth per the frost-depth table plus insulation and drainage detailing; footing depth may not be less than the local frost line unless designed.

  • Story height above grade plane determines whether the building falls within the IRC: not more than three stories above grade plane.

  • Site grading: the ground within 6 in. of the foundation shall slope away at not less than 6 in. fall in the first 10 ft.

Quick reference

Floor, Wall, and Roof Construction

  • Floor joists: sawn-lumber spans are taken from the joist span tables and are limited by species/grade, size, spacing, and live load; notches in the top or bottom are limited to one-sixth of depth.

  • Bored holes in floor joists: diameter not more than one-third of joist depth, located not closer than 2 in. to the top or bottom edge and not in the middle third of the span where the hole diameter exceeds one-third.

  • Wall studs: size and spacing from the wall table; notching of exterior and bearing wall studs is limited to 25 percent of width, and boring to 40 percent of width.

  • Headers and lintels over openings are sized by span tables and must be supported by jack studs or an approved hanger; bearing length on wood or metal is at least 1 1/2 in.

  • Roof framing: rafters and ceiling joists are sized from span tables; rafter ties or a structural ridge resist thrust, and collar ties alone are not a substitute for rafter ties.

  • Rough sill and band joists must be anchored to the foundation with anchor bolts spaced not more than 6 ft on center, with at least two bolts per plate section and not less than 7 in. embedment.

  • Wood decay protection: wood in contact with the ground or in a crawl space must be naturally durable or preservative-treated; fasteners must be compatible with the treatment.

  • Trusses must be designed and installed per approved truss drawings; cutting, notching, or altering a truss member is prohibited.

Quick reference

Energy Efficiency and Interior Environment

  • The energy provisions require a building thermal envelope that limits heat loss and gain, with insulation installed in substantial contact with the surface it insulates and in full conformity with the labeled R-value.

  • Building thermal envelope values (R-values and U-factors) are set by climate zone; the same assembly has different requirements in zones 1 through 8.

  • Air leakage: the building thermal envelope must be sealed at penetrations, joints, and seams; recessed luminaires in the envelope must be sealed and rated for insulation contact.

  • Ducts and HVAC equipment located outside the conditioned space must be insulated and sealed; duct leakage testing applies where required by the adopted energy chapter.

  • Whole-house mechanical ventilation is required where the envelope is tightened; exhaust fans must vent to the outdoors, not into attics or crawl spaces.

  • Interior environment: bathrooms, toilet rooms, and kitchens require local exhaust; habitable rooms require natural or mechanical ventilation per the ventilation table.

  • Combustion air: fuel-burning appliances in a confined space require outdoor combustion air sized by the appliance input rating, or the space must be classified as unconfined.

  • Moisture control: a vapor retarder is required on the warm side of the assembly as specified, and crawl spaces must have a ground cover of at least 6-mil material.

Quick reference

Fire and Life Safety Provisions

  • Smoke alarms: required in each sleeping room, outside each sleeping area in the immediate vicinity, and on each additional story including basements; they must be interconnected.

  • Smoke alarm power source: primary power from the building wiring with battery backup, or a listed battery-only alarm where permitted for existing or non-remodeled dwellings.

  • Carbon monoxide alarms are required outside sleeping areas and on each story where the dwelling contains a fuel-burning appliance or an attached garage.

  • Fire separation: a one-hour fire-resistance rating is required between a dwelling unit and an attached private garage, and between townhouse units, with doors of at least 20-minute rating.

  • Egress doors must be side-hinged, at least 32 in. clear width, and at least 6 ft 8 in. tall; the required exit door must be readily openable from the inside without a key or tool.

  • Egress window wells: where an emergency escape opening is below grade, a ladder or steps and a minimum well area and horizontal projection are required.

  • Fireblocking is required at concealed spaces: between floor and ceiling, at the top and bottom of stair stringers, and at penetrations through wall and floor assemblies.

  • Draftstopping is required in concealed attic and floor spaces to limit the horizontal spread of fire; the maximum area of a draftstopped space is specified in the fire chapter.