ICC R5 flashcards
ICC R5 · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- IRC building scope
- The IRC applies to detached one- and two-family dwellings and townhouses not more than three stories above grade plane with a separate means of egress, plus accessory structures.
- Permit exemption
- Ordinary repairs, listed minor work, and certain accessory structures below the size threshold do not require a permit, but all work must still comply with the code.
- Certificate of occupancy
- Issued after the completed work is inspected and found to comply with the approved construction documents; it authorizes occupancy of the building or unit.
- Permit lapse period
- A permit becomes invalid if work does not start within 180 days of issuance, or if work is suspended or abandoned for 180 days, unless the local ordinance states otherwise.
- Board of appeals
- A body appointed to hear appeals of the building official's interpretations and decisions; filing an appeal stays enforcement unless the official certifies an immediate hazard.
- Habitable room glazing
- Every habitable room must have aggregate glazing of at least 8 percent of the floor area and openable area of at least 4 percent for natural light and ventilation.
- Minimum ceiling height
- Habitable rooms, halls, and corridors need 7 ft clear; bathrooms, toilet rooms, and laundry rooms need 6 ft 8 in. clear, measured to the finished ceiling.
- Emergency escape opening size
- The net clear opening must be at least 5.7 square feet, or 5.0 square feet for openings at grade, with minimum width 20 in. and height 24 in.
- Escape opening sill height
- The sill of an emergency escape and rescue opening must be not more than 44 in. above the finished floor, so an occupant can reach and exit the opening.
- Minimum footing dimensions
- Footings are at least 12 in. wide and 6 in. thick, bear on undisturbed soil below the frost line, and project beyond the wall face only as limited by table.
- Foundation grade slope
- The ground within 6 in. of the foundation must slope away at not less than 6 in. of fall in the first 10 ft to drain water away from the footings.
- Joist notch limit
- Notches in floor joists are limited to one-sixth of the joist depth, and notches may not be located in the middle third of the span where tension stress is highest.
- Joist bored hole limit
- Hole diameter may not exceed one-third of the joist depth, and holes must be at least 2 in. from the top and bottom edges of the member.
- Stud notch and bore limits
- In exterior and bearing wall studs, notching is limited to 25 percent of the stud width and boring to 40 percent of the width, with edge distance limits.
- Sill plate anchor bolts
- Anchor bolts spaced not more than 6 ft on center, with at least two per plate section and at least 7 in. embedment in the foundation, anchor the sill to the foundation.
- Rafter thrust restraint
- Rafters must be tied with ceiling joists or a structural ridge to resist outward thrust at the walls; collar ties alone do not provide this restraint.
- Truss alteration prohibition
- Engineered trusses must be installed per the approved truss design drawings; cutting, notching, or altering any truss member is prohibited without the truss designer's approval.
- Decay-resistant wood
- Wood in contact with the ground or in crawl spaces must be naturally durable or preservative-treated, and fasteners must be compatible with the treatment to avoid corrosion.
- Header bearing length
- Headers and lintels over openings must bear at least 1 1/2 in. on wood or metal supports, with jack studs or approved hangers carrying the load.
- Climate zone envelope
- The energy chapter sets insulation R-values and fenestration U-factors by climate zone, so the same wall or window assembly has different requirements across zones 1 through 8.
- Envelope air sealing
- The building thermal envelope must be sealed at joints, seams, and penetrations; recessed luminaires in the envelope must be sealed and rated for insulation contact.
- Whole-house ventilation
- Where the envelope is tightened, the dwelling must have a whole-house mechanical ventilation system; exhaust fans must discharge outdoors, not into attics or crawl spaces.
- Local exhaust requirement
- Bathrooms, toilet rooms, and kitchens require local exhaust ventilation, and habitable rooms require natural or mechanical ventilation per the ventilation table.
- Combustion air sizing
- Fuel-burning appliances in a confined space need outdoor combustion air sized by the appliance input rating, or the space must be classified as unconfined.
- Crawl space ground cover
- Crawl spaces require a ground cover of at least 6-mil material to limit moisture migration into the dwelling, lapped and sealed at joints and edges.
- Smoke alarm locations
- Smoke alarms are required in each sleeping room, outside each sleeping area in the immediate vicinity, and on each additional story including basements, and must be interconnected.
- Smoke alarm power source
- Alarms must have primary power from the building wiring with battery backup, or be listed battery-only alarms where the code permits for existing or unremodeled dwellings.
- Carbon monoxide alarms
- CO alarms are required outside sleeping areas and on each story where the dwelling has a fuel-burning appliance or an attached garage, following the manufacturer's listing.
- Garage fire separation
- A one-hour fire-resistance rating is required between a dwelling unit and an attached private garage, with doors of at least 20-minute rating and self-closing hardware.
- Egress door requirements
- The required exit door must be side-hinged, at least 32 in. clear width and 6 ft 8 in. tall, and openable from the inside without a key or special tool.
- Fireblocking locations
- Fireblocking is required in concealed spaces, including between floor and ceiling, at the top and bottom of stair stringers, and at penetrations through wall and floor assemblies.
- Draftstopping purpose
- Draftstopping in concealed attic and floor spaces limits the horizontal spread of fire and smoke; the fire chapter specifies the maximum area of each draftstopped space.