The ICC Fire Inspector II credential is one of the certifications administered through the International Code Council's credentialing program, which the ICC describes as "one of the most historic and prestigious credentialing programs for construction codes and standards." It is aimed at fire inspectors who already hold the Fire Inspector I level and want to advance into more complex inspection work - site plan review, hazardous occupancy and storage considerations, fire protection system acceptance, and inspection program management. The ICC notes that it "offers reciprocity for various certifications from the NCPCCI and ProBoard Accredited Fire Inspector I and II certifications," so holders of those credentials may be able to transition rather than retest. The ICC 67 case studies are 5 cases and about 2,530 words.

1

Second-Floor Dance Studio Change of Occupancy

A tenant improvement permit proposes converting a 2,400 ft² second-floor suite in a two-story Type V-B building from business offices to a dance studio. The building has one interior exit stair 44 inches wide serving both floors; the first floor contains 3,000 ft² of mercantile.

613 words, about 3 min
2

High-Piled Plastic Storage in an Existing ESFR Warehouse

A 12,000 ft² warehouse with a 24-foot ceiling and an existing ESFR sprinkler system is leased to a new tenant. The previous tenant stored Class II commodity on racks 12 feet high.

485 words, about 2 min
3

Residential Board and Care Conversion with Nonambulatory Residents

A single-family house is being converted to a residential board and care facility for eight residents, two of whom are nonambulatory. The house has three bedrooms on the second floor and two on the first floor, a single open interior stair, and a basement used for laundry and storage.

496 words, about 2 min
4

Commercial Cooking Hood Suppression Impairment

A 180-seat restaurant has a 12-foot commercial cooking hood over a gas range and two fryers. The hood has a listed wet-chemical suppression system with two nozzles and a manual pull station.

466 words, about 2 min
5

Fire Alarm and Sprinkler Modifications Without Permit

A 30,000 ft², three-story office building has an existing addressable fire alarm system and a wet sprinkler system. A tenant remodel on the second floor adds 12 offices and a break room, relocates 15 sprinkler heads, and adds four smoke detectors.

470 words, about 2 min